Frontiers in Optics

Three laser Recoil-induced Resonance in a Magneto-Optical Trap

Frank A. Narducci, J. P. Davis, K. Gordon, S. A. DeSavage, D. Duncan, George R. Welch

Published Jan 1, 2010• 0 citations
Publisher

Abstract

In this work we discuss our recent experiments to measure recoil-induced resonances that revealed, in addition to the expected narrow resonance, a much broader resonance that does not seem to fit current models.
DOI
10.1364/ls.2010.ltuj2

Related papers

Dynamics of a narrow line magneto-optical trap

Thomas H. Loftus, T. Ido, Andrew D. Ludlow +2 more

We present a detailed study of the thermodynamic and mechanical properties of a single photon recoil limited 1S0–3P188Sr Magneto-Optical Trap for trapping laser frequencies both below and above the atomic resonance.

Conference on Lasers and Electro-Optics•Jan 1, 2004•0 citations

An experimental investigation of the trap-dynamics of a cesium magneto-optical trap at high laser intensities

Muhammad Anwar, Muhammad Hamza Faisal, Mushtaq Ahmed

The European Physical Journal D•Dec 1, 2013•5 citations

Recoil-induced resonances for optical switching

K. Gordon, S. A. DeSavage, D. Duncan +3 more

We have investigated recoil-induced resonances in laser-cooled atoms for the purpose of developing an optical switch. In contrast to our earlier experiments Citation8, we employ a system in which the trapping beams are left on during the course of the measurement. We not only find the expected narrow resonance but also a much wider resonance. The widths of the wide and narrow resonances differ by three orders of magnitude. In addition, the two resonances show different temporal dynamics. We explore the utility of each resonance as an optical switch.

Journal of Modern Optics•Nov 10, 2010•6 citations

High-order resonances in a parametrically excited magneto-optical trap

Heung‐Ryoul Noh, Kihwan Kim, Wonho Jhe

Optics Communications•Jul 11, 2006•3 citations

Observation of recoil-induced resonances and electromagnetically induced absorption of diffuse light by cold atoms

Wenzhuo Zhang, Hua-Dong Cheng, Liang Liu +1 more

In this paper we report an experiment on the observation of the recoil-induced resonances (RIR) and electromagnetically induced absorption (EIA) of cold $^{87}\text{R}\text{b}$ atoms in diffuse light. The pump light of the RIR and the EIA comes from the diffuse light in an integrating sphere, which also serves the cooling light. We measured the RIR and the EIA signal varying with the detuning of the diffuse laser light, and also measured the number and the temperature of the cold atoms at the different detunings. The mechanism of RIR and EIA in the configuration with diffuse-light pumping and laser probing are discussed, and the difference between the nonlinear spectra of cold atoms in a diffuse-light cooling system and in a magneto-optical trap is studied.

arXiv:0901.1706•Physical Review A•May 1, 2009•14 citations

Parametric resonance in an intensity-modulated magneto-optical trap

Kihwan Kim, Heung‐Ryoul Noh, Wonho Jhe

Optics Communications•Mar 25, 2004•27 citations
We have investigated recoil-induced resonances in laser-cooled atoms for the purpose of developing an optical switch. In contrast to our earlier experiments Citation8, we employ a system in which the trapping beams are left on during the course of the measurement. We not only find the expected narrow resonance but also a much wider resonance. The widths of the wide and narrow resonances differ by three orders of magnitude. In addition, the two resonances show different temporal dynamics. We explore the utility of each resonance as an optical switch.
In this paper we report an experiment on the observation of the recoil-induced resonances (RIR) and electromagnetically induced absorption (EIA) of cold 87Rb^{87}\text{R}\text{b}87Rb atoms in diffuse light. The pump light of the RIR and the EIA comes from the diffuse light in an integrating sphere, which also serves the cooling light. We measured the RIR and the EIA signal varying with the detuning of the diffuse laser light, and also measured the number and the temperature of the cold atoms at the different detunings. The mechanism of RIR and EIA in the configuration with diffuse-light pumping and laser probing are discussed, and the difference between the nonlinear spectra of cold atoms in a diffuse-light cooling system and in a magneto-optical trap is studied.