Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

Laser optical pumping in Rb vapour-cell atomic clocks (Invited Paper)

G. Mileti, C. Affolderbach

Published Apr 22, 2005• 0 citations
Publisher

Abstract

We discuss the basic physical principles of laser optical pumping double-resonance spectroscopy, which form the basis of state-of-the-art vapour-cell atomic frequency standards using laser optical pumping of Rb atoms. The main effects limiting the frequency stability of Rb vapour-cell atomic clocks are identified, and their impact on the development of high-performance frequency standars and their transfer from research laboratories to industry and space is discussed. As examples, the impact of the AC stark effect and the realated issue of laser frequency stabilisation are dealt with in more detail. The main features of the present state-of-the-art Rb atomic frequency standards will be illustrated using the example of the development of atomic clocks for satellite navigation and positioning systems (GPS, GLONAS, GALILEO, etc.) as well as some directions for further improvements that could overcome present day limitations. Such compact Rb clocks find their applications in, for example, telecommunications, local timekeeping and synchronisation, and space applications like satellite navigation and science missions. An overview of other, alternative clock schemes is given and critical issues for future developments towards further performance improvement or device miniaturisation in the field of vapour-cell atomic clocks are discussed.

DOI
10.1117/12.617754

Related papers

Gas-cell atomic clocks for space: new results and alternative schemes

C. Affolderbach, Evelina Breschi, C. Schori +1 more

We present our development activities on compact Rubidium gas-cell atomic frequency standards, for use in space-borne and ground-based applications. We experimentally demonstrate a high-performance laser optically-pumped Rb clock for space applications such as telecommunications, science missions, and satellite navigation systems (e.g. GALILEO). Using a stabilised laser source and optimized gas cells, we reach clock stabilities as low as 1.5·10-12 τ-1/2 up to 103 s and 4·10-14 at 104 s. The results demonstrate the feasibility of a laser-pumped Rb clock reaching < 1·10-12 τ-1/2 in a compact device (<2 liters, 2 kg, 20 W), given optimization of the implemented techniques. A second activity concerns more radically miniaturized gas-cell clocks, aiming for low power consumption and a total volume around 1 cm3 , at the expense of relaxed frequency stability. Here miniaturized “chip-scale” vapour cells and use of coherent laser interrogation techniques are at the heart of the investigations.

International Conference on Space Optics (ICSO)•Nov 21, 2017•2 citations

High performance vapour-cell frequency standards

Mohammadreza Gharavipour, C. Affolderbach, Songbai Kang +4 more

We report our investigations on a compact high-performance rubidium (Rb) vapourcell clock based on microwave-optical double-resonance (DR).These studies are done in both DR continuous-wave (CW) and Ramsey schemes using the same Physics Package (PP), with the same Rb vapour cell and a magnetron-type cavity with only 45 cm 3 external volume.In the CW-DR scheme, we demonstrate a DR signal with a contrast of 26% and a linewidth of 334 Hz; in Ramsey-DR mode Ramsey signals with higher contrast up to 35% and a linewidth of 160 Hz have been demonstrated.Short-term stabilities of 1.4×10 -13 τ -1/2 and 2.4×10 -13 τ -1/2 are measured for CW-DR and Ramsey-DR schemes, respectively.In the Ramsey-DR operation, thanks to the separation of light and microwave interactions in time, the light-shift effect has been suppressed which allows improving the long-term clock stability as compared to CW-DR operation.Implementations in miniature atomic clocks are considered. IntroductionSince the first invention of lamp-pumped rubidium (Rb) clocks in the 1960's [1,2], the demand for a stable, reliable, and compact Rb frequency standard with low power consumption has been growing, for various applications fields such as industry, telecommunication, navigation, space applications (e.g.GPS [3], GALILEO [4] and COMPASS [5]).Recently, thanks to the semiconductor laser technology, laser-pumped Rb clocks have been considered in several studies, for their better optical pumping efficiency results in short-term frequency stabilities at least one order of magnitude better than their lamp-pumped counterparts [6][7][8][9].This opened up also several new schemes for vapour-cell atomic clocks, such as the continuous-wave (CW) Rb clock [9], coherent population trapping (CPT) Cs clock [10] and pulsed optical pumping (POP) Rb clock [11].In this paper we report our studies on high-performance Rb frequency standards based on the laser-microwave double-resonance (DR) scheme, using both CW and Ramsey interrogation.Both CW-DR and Ramsey-DR schemes require two resonant electromagnetic fields of light and microwave.In the case of CW-DR, the laser optically pumps the vapour of the Rb atoms by creating a polarization of the atomic ground-state; simultaneously the microwave field, generated from a quartz oscillator and is near-resonant with the 87 Rb hyperfine clock transition (energy levels 5 2 S 1/2 │F g =1, m F =0˃ ↔│F g =2, m F =0˃), is applied.The opacity of the Rb vapour to the transmitted light signal as a function of microwave frequency is a measure of the atomic ground state polarization known as CW-DR signal [9].In CW-DR, the steps of optical pumping, microwave interrogation and optical detection are applied simultaneously (figure 1(b)).In the case of Ramsey-DR, these three sequences are separated in time, see figure 1(c): first, during optical pumping a strong laser pulse creates a significant atom population imbalance between

Journal of Physics Conference Series•Jun 1, 2016•20 citations

A compact, high-performance laser-pumped rubidium atomic frequency standard

C. Affolderbach, G. Mileti, Fabien Droz

The paper presents the realisation of a high-performance vapour-cell atomic frequency standard demonstrator based on laser optical pumping. The development of such devices aims to fully exploit the advantages of using a narrow-band diode laser pump light source instead of the discharge lamps commonly used in Rb gas-cell clocks. These advantages include improved control over the pump light spectrum, higher selectivity of the optical pumping, and increased signal contrast, and thus show the potential for the realisation of Rb atomic clocks with improved short-term frequency stability.

European Quantum Electronics Conference (EQEC)•Jan 18, 2006•1 citation

Double-resonance spectroscopy in Rubidium vapour-cells for high performance and miniature atomic clocks

Mohammadreza Gharavipour, C. Affolderbach, Songbai Kang +1 more

We report our studies on using microwave-optical double-resonance (DR) spectroscopy for a high-performance Rb vapour-cell atomic clock in view of future industrial applications.The clock physics package is very compact with a total volume of only 0.8 dm 3 .It contains a recently in-house developed magnetron-type cavity and a Rb vapour cell.A homedmade frequency-stabilized laser system with an integrated acousto-optical-modulator (AOM)for switching and controlling the light output power-is used as an optical source in a laser head (LH).The LH has the overall volume of 2.5 dm 3 including the laser diode, optical elements, AOM and electronics.In our Rb atomic clock two schemes of continuous-wave DR and Ramsey-DR schemes are used, where the latter one strongly reduces the light-shift effect by separation of the interaction of light and microwave.Applications of the DR clock approach to more radically miniaturized atomic clocks are discussed.

Journal of Physics Conference Series•Jan 1, 2017•2 citations

A laser optically-pumped Rubidium vapour-cell frequency standard using a DFB laser diode

C. Affolderbach, G. Mileti, Fabien Droz

A laser optically-pumped vapour-cell atomic frequency standard ("Rb clock") using a DFB laser diode as pump light source is presented. The Rb clock is based on probing the ground-state hyperfine "clock" transition at 6.8 GHz of atomic87Rb, by optical-microwave double-resonance technique. The frequency stability of the clock is measured.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2007•0 citations

Double-resonance studies on compact, high-performance rubidium cell frequency standards

Thejesh Bandi Nagabhushan

This thesis presents experimental studies on continuous-wave (CW) laser-microwave double-resonance (DR) spectroscopy and metrology in rubidium (87Rb) vapor cells in view of new high-performance, compact Rb-cell atomic clocks. The Rb vapor cell is confined inside a magnetron-type cavity microwave resonator (MWR). The CW DR spectroscopy involves two resonant electromagnetic fields that are operated simultaneously to interrogate the atoms - the optical field to polarize the atoms by optical pumping, and the microwave field to drive the ground-state hyperfine clock transition that serves as an atomic frequency reference. Details on characterization of compact laser heads and microwave synthesizers used in this work are presented. The vapor cell standards are useful in our everyday lives for applications ranging from telecommunications, navigation, metrology etc. In view of improving the performances of the Rb cell standards, two different clock approaches were studied in detail: The first one is on use of vapor cells (1.4 cm3) whose inner walls are coated with anti-relaxation material. A first ever wall-coated cell clock was demonstrated with good short-term frequency stability. The medium- to long-term stability was found to be limited by the temperature coefficient (TC) of the coating material itself. This work gave the insight to important features to be considered in future anti-relaxation coating materials for atomic standards. The second novel approach involves using a bigger cell (12 cm3) within a newly developed, improved MWR towards a high-performance atomic standard. Adopting a larger cell gives a higher atomic Q-factor signal that improves the short-term clock stability. In this approach, the cell was filled with 87Rb and buffer gases. With this clock, we demonstrate the state-of-the-art short-term stability of <1.4×10−13 τ−1/2. Metrological quantitative measurements on parameters influencing the medium- to long-term stability were studied in view of next generation satellite navigation systems that demand a stability level of <1×10−14 at 10 4 s (equivalent to <1 ns/day). The potential of short-term stability and understanding of the limiting factors on medium- to long-term time scales demonstrated in this study pave the way for future work towards the commercialization of high-performance Rb atomic clocks for a variety of applications.

•Jan 1, 2013•2 citations
We discuss the basic physical principles of laser optical pumping double-resonance spectroscopy, which form the basis of state-of-the-art vapour-cell atomic frequency standards using laser optical pumping of Rb atoms. The main effects limiting the frequency stability of Rb vapour-cell atomic clocks are identified, and their impact on the development of high-performance frequency standars and their transfer from research laboratories to industry and space is discussed. As examples, the impact of the AC stark effect and the realated issue of laser frequency stabilisation are dealt with in more detail. The main features of the present state-of-the-art Rb atomic frequency standards will be illustrated using the example of the development of atomic clocks for satellite navigation and positioning systems (GPS, GLONAS, GALILEO, etc.) as well as some directions for further improvements that could overcome present day limitations. Such compact Rb clocks find their applications in, for example, telecommunications, local timekeeping and synchronisation, and space applications like satellite navigation and science missions. An overview of other, alternative clock schemes is given and critical issues for future developments towards further performance improvement or device miniaturisation in the field of vapour-cell atomic clocks are discussed.
We present our development activities on compact Rubidium gas-cell atomic frequency standards, for use in space-borne and ground-based applications. We experimentally demonstrate a high-performance laser optically-pumped Rb clock for space applications such as telecommunications, science missions, and satellite navigation systems (e.g. GALILEO). Using a stabilised laser source and optimized gas cells, we reach clock stabilities as low as 1.5·10-12 τ-1/2 up to 103 s and 4·10-14 at 104 s. The results demonstrate the feasibility of a laser-pumped Rb clock reaching < 1·10-12 τ-1/2 in a compact device (<2 liters, 2 kg, 20 W), given optimization of the implemented techniques. A second activity concerns more radically miniaturized gas-cell clocks, aiming for low power consumption and a total volume around 1 cm3 , at the expense of relaxed frequency stability. Here miniaturized “chip-scale” vapour cells and use of coherent laser interrogation techniques are at the heart of the investigations.
We report our investigations on a compact high-performance rubidium (Rb) vapourcell clock based on microwave-optical double-resonance (DR).These studies are done in both DR continuous-wave (CW) and Ramsey schemes using the same Physics Package (PP), with the same Rb vapour cell and a magnetron-type cavity with only 45 cm 3 external volume.In the CW-DR scheme, we demonstrate a DR signal with a contrast of 26% and a linewidth of 334 Hz; in Ramsey-DR mode Ramsey signals with higher contrast up to 35% and a linewidth of 160 Hz have been demonstrated.Short-term stabilities of 1.4×10 -13 τ -1/2 and 2.4×10 -13 τ -1/2 are measured for CW-DR and Ramsey-DR schemes, respectively.In the Ramsey-DR operation, thanks to the separation of light and microwave interactions in time, the light-shift effect has been suppressed which allows improving the long-term clock stability as compared to CW-DR operation.Implementations in miniature atomic clocks are considered. IntroductionSince the first invention of lamp-pumped rubidium (Rb) clocks in the 1960's [1,2], the demand for a stable, reliable, and compact Rb frequency standard with low power consumption has been growing, for various applications fields such as industry, telecommunication, navigation, space applications (e.g.GPS [3], GALILEO [4] and COMPASS [5]).Recently, thanks to the semiconductor laser technology, laser-pumped Rb clocks have been considered in several studies, for their better optical pumping efficiency results in short-term frequency stabilities at least one order of magnitude better than their lamp-pumped counterparts [6][7][8][9].This opened up also several new schemes for vapour-cell atomic clocks, such as the continuous-wave (CW) Rb clock [9], coherent population trapping (CPT) Cs clock [10] and pulsed optical pumping (POP) Rb clock [11].In this paper we report our studies on high-performance Rb frequency standards based on the laser-microwave double-resonance (DR) scheme, using both CW and Ramsey interrogation.Both CW-DR and Ramsey-DR schemes require two resonant electromagnetic fields of light and microwave.In the case of CW-DR, the laser optically pumps the vapour of the Rb atoms by creating a polarization of the atomic ground-state; simultaneously the microwave field, generated from a quartz oscillator and is near-resonant with the 87 Rb hyperfine clock transition (energy levels 5 2 S 1/2 │F g =1, m F =0˃ ↔│F g =2, m F =0˃), is applied.The opacity of the Rb vapour to the transmitted light signal as a function of microwave frequency is a measure of the atomic ground state polarization known as CW-DR signal [9].In CW-DR, the steps of optical pumping, microwave interrogation and optical detection are applied simultaneously (figure 1(b)).In the case of Ramsey-DR, these three sequences are separated in time, see figure 1(c): first, during optical pumping a strong laser pulse creates a significant atom population imbalance between
The paper presents the realisation of a high-performance vapour-cell atomic frequency standard demonstrator based on laser optical pumping. The development of such devices aims to fully exploit the advantages of using a narrow-band diode laser pump light source instead of the discharge lamps commonly used in Rb gas-cell clocks. These advantages include improved control over the pump light spectrum, higher selectivity of the optical pumping, and increased signal contrast, and thus show the potential for the realisation of Rb atomic clocks with improved short-term frequency stability.
We report our studies on using microwave-optical double-resonance (DR) spectroscopy for a high-performance Rb vapour-cell atomic clock in view of future industrial applications.The clock physics package is very compact with a total volume of only 0.8 dm 3 .It contains a recently in-house developed magnetron-type cavity and a Rb vapour cell.A homedmade frequency-stabilized laser system with an integrated acousto-optical-modulator (AOM)for switching and controlling the light output power-is used as an optical source in a laser head (LH).The LH has the overall volume of 2.5 dm 3 including the laser diode, optical elements, AOM and electronics.In our Rb atomic clock two schemes of continuous-wave DR and Ramsey-DR schemes are used, where the latter one strongly reduces the light-shift effect by separation of the interaction of light and microwave.Applications of the DR clock approach to more radically miniaturized atomic clocks are discussed.
This thesis presents experimental studies on continuous-wave (CW) laser-microwave double-resonance (DR) spectroscopy and metrology in rubidium (87Rb) vapor cells in view of new high-performance, compact Rb-cell atomic clocks. The Rb vapor cell is confined inside a magnetron-type cavity microwave resonator (MWR). The CW DR spectroscopy involves two resonant electromagnetic fields that are operated simultaneously to interrogate the atoms - the optical field to polarize the atoms by optical pumping, and the microwave field to drive the ground-state hyperfine clock transition that serves as an atomic frequency reference. Details on characterization of compact laser heads and microwave synthesizers used in this work are presented. The vapor cell standards are useful in our everyday lives for applications ranging from telecommunications, navigation, metrology etc. In view of improving the performances of the Rb cell standards, two different clock approaches were studied in detail: The first one is on use of vapor cells (1.4 cm3) whose inner walls are coated with anti-relaxation material. A first ever wall-coated cell clock was demonstrated with good short-term frequency stability. The medium- to long-term stability was found to be limited by the temperature coefficient (TC) of the coating material itself. This work gave the insight to important features to be considered in future anti-relaxation coating materials for atomic standards. The second novel approach involves using a bigger cell (12 cm3) within a newly developed, improved MWR towards a high-performance atomic standard. Adopting a larger cell gives a higher atomic Q-factor signal that improves the short-term clock stability. In this approach, the cell was filled with 87Rb and buffer gases. With this clock, we demonstrate the state-of-the-art short-term stability of <1.4×10−13 τ−1/2. Metrological quantitative measurements on parameters influencing the medium- to long-term stability were studied in view of next generation satellite navigation systems that demand a stability level of <1×10−14 at 10 4 s (equivalent to <1 ns/day). The potential of short-term stability and understanding of the limiting factors on medium- to long-term time scales demonstrated in this study pave the way for future work towards the commercialization of high-performance Rb atomic clocks for a variety of applications.