Physical Review A

Type-I spontaneous parametric down-conversion with a strongly focused pump

H. Di Lorenzo Pires, F. M. G. J. Coppens, Martin P. van Exter

Published Mar 31, 2011• 46 citations
Publisher

Abstract

We experimentally study the spatial properties of the field generated by spontaneous parametric down-conversion (SPDC) when the pump laser beam is strongly focused in the nonlinear crystal. Special attention is paid to classical intensity measurements with a CCD camera. We introduce the concept of a classical equivalent source that replicates all the coherence properties of SPDC light and explains all our experimental results. We show that, in contrast with experiments with a well-collimated pump, here both the phase-matching conditions and the position of the focusing plane determine the measured intensity profiles in the image plane of the crystal. The transition from the near-field regime to the far field is investigated. Measurements of two-photon correlations under strong focusing are also presented and the special features thereof are discussed.

DOI
10.1103/physreva.83.033837

Related papers

Purely spatial coincidences in parametric spontaneous down conversion

Jean-Luc Blanchet, F. Devaux, Luca Furfaro +1 more

Spontaneous down conversion (SPDC) occurs in a nonlinear crystal when a pump photon splits in a pair of signal and idler photons. This paper demonstrates detection of single photons in low light level images with an electron multiplying CCD camera (EMCCD). The opposite spatial fluctuations of SPDC radiation are correlated in the quantum regime. Here, correlations between pixels are presented for collinear phase matching. The far field image of the parametric fluorescence is formed in the focal plane of a lens on a back-illuminated EMCCD. A thresholding procedure is applied on each image, in order to decide whether there is one or zero photo-electron on each pixel. We have experimentally demonstrated that spatial SPDC fluctuations between opposite pixels are quantum correlated in the far field.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2009•0 citations

Spatial and temporal characteristics of spontaneous parametric down-conversion with varying focal planes of interacting beams

Bernecker, Richard, Baghdasar Baghdasaryan, S. Fritzsche

Spontaneous parametric down-conversion (SPDC) is a widely used process to prepare entangled photon pairs. In SPDC, a second-order nonlinear crystal is pumped by a coherent laser beam to generate photon pairs. The photon pairs are usually detected by single-mode fibers (SMF), where only photons in a Gaussian mode can be collected. The collection modes possess typical Gaussian parameters, namely a beam waist and a focal plane position. The collection efficiency of photons highly depends on the choice of both parameters. The exact focal plane position of the pump beam relative to those of the detection modes is difficult to determine in a real experiment. Usually, theoretical and experimental studies assume that the focal plane positions of the pump and the generated beams are positioned in the center of the crystal. The displacement of beam focal planes can lead to deviations from expected results and the coupling efficiency into SMF can increase or decrease. In this work, we consider variable positions of focal planes and investigate how shifts of these focal planes influence the spatial and temporal properties of photon pairs. We present SPDC arrangements, in which the knowledge of the exact position of the focal planes is essential, as well as scenarios, where focal plane displacements do not contribute significantly to experimental outcomes. These findings are of particular interest for achieving higher efficiency in SPDC experiments.

arXiv:2212.12571•Dec 23, 2022•0 citations

Spatial and spectral peculiarities of spontaneous parametric down-conversion for classical and quantum spectroscopy

Jean-Michel Melkonian, Julien Le Gouët, Enguerran Belles +2 more

Spontaneous Parametric Down-conversion (SPDC) is now routinely used to generate photon pairs for imaging, spectroscopy, and quantum information and metrology. However, the peculiar spectro-spatial properties of SPDC beams are not always known from the largest audience: they can give rise to ring-like beams, depending on the temperature, the wavelengths and pump focusing. This has to be considered for imaging or long-range applications. We will show examples of such beams created in 532-pumped PPLN or PPKTP and 1064-nm-pumped PPLN crystals. With a simple model of noncolinear phase matching we will give physical insight into the phenomena and explain the role of the signal/idler group delay. We will also explain how aperiodic crystals could be useful.

SPIE Quantum Technologies for Defence and Security•Nov 15, 2024•0 citations

Semi-classical modelling of second-order spontaneous down-conversion measured over 10 decades of pump intensity in a type II phase-matched KTP crystal

Julien Bertrand, Véronique Boutou, Benoı̂t Boulanger

We performed a second-order spontaneous parametric down-conversion (SPDC) experiment in a Type II phase-matched KTiOPO4 crystal pumped at 532 nm giving birth to a signal beam at 1037 nm and an idler one at 1092 nm along the x-axis of the crystal. Three pump sources have been used: in the continuous-wave, nanosecond (200 ns, 1 kHz) and picosecond (15 ps, 10 Hz) regimes. That allowed us to cover a pump intensity range from 2.4 W.cm-2 to 3.7 GW.cm-2 which led to the generation of twin photons with a flux from 1.1x104 Hz to 1.2x1021 Hz, respectively, the corresponding quantum efficiencies being of 1.8x10-11 and 9.2x10-4. We identified two SPDC regimes regarding the pump intensity: one below 30 MW.cm-2 for which the flux increases linearly, and the other one above 30 MW.cm-2 for which the flux behaves exponentially. We proposed a semi-classical model under the undepleted pump approximation based on both the quantum fluctuations of vacuum for the seeding of the process and a propagation step ensured by classical fields, which allowed a satisfying description of these two regimes, with a much better agreement at high intensity than the quantum models based on the nonlinear momentum or the nonlinear Hamiltonian operators.

arXiv:2502.04815•Feb 7, 2025•0 citations

Transverse coherence of photon pairs generated in spontaneous parametric down-conversion

Martin Hamar, Jan Peřina, Ondřej Haderka +1 more

Coherence properties of the down-converted beams generated in spontaneous parametric down-conversion are investigated in detail using an iCCD camera. Experimental results are compared with those from a theoretical model developed for pulsed pumping with a Gaussian transverse profile. The results allow us to tailor the shape of correlation area of the signal and idler photons using pump-field and crystal parameters. As an example, splitting of a correlation area caused by a two-peak pump-field spectrum is experimentally studied.

arXiv:1003.1249•Physical Review A•Apr 21, 2010•45 citations

Spatial and temporal characteristics of spontaneous parametric down-conversion with varying focal planes of interacting beams

Richard Bernecker, Baghdasar Baghdasaryan, S. Fritzsche

Abstract Spontaneous parametric down-conversion (SPDC) is a widely used process to prepare entangled photon pairs. In SPDC, a second-order nonlinear crystal is pumped by a coherent laser beam to generate photon pairs. The photon pairs are usually detected by single-mode fibers (SMF), where only photons in a Gaussian mode can be collected. The collection modes possess typical Gaussian parameters, namely a beam waist and a focal plane position. The collection efficiency of photons highly depends on the choice of both parameters. The exact focal plane position of the pump beam relative to those of the detection modes is difficult to determine in a real experiment. Usually, theoretical and experimental studies assume that the focal plane positions of the pump and the generated beams are positioned in the center of the crystal. The displacement of beam focal planes can lead to deviations from expected results and the coupling efficiency into SMF can decrease. In this study, we theoretically examine variable positions of focal planes in the Laguerre–Gaussian basis, a popular experimental modal decomposition of the spatial biphoton state. We explore how the choice of focal plane positions affects the spatial and temporal properties and the purity of the photon pairs. We present SPDC setups where precise knowledge of the focal plane position is essential and scenarios where focal plane displacements have negligible impact on experimental outcomes. Graphical Abstract

The European Physical Journal D•Sep 1, 2023•4 citations
We experimentally study the spatial properties of the field generated by spontaneous parametric down-conversion (SPDC) when the pump laser beam is strongly focused in the nonlinear crystal. Special attention is paid to classical intensity measurements with a CCD camera. We introduce the concept of a classical equivalent source that replicates all the coherence properties of SPDC light and explains all our experimental results. We show that, in contrast with experiments with a well-collimated pump, here both the phase-matching conditions and the position of the focusing plane determine the measured intensity profiles in the image plane of the crystal. The transition from the near-field regime to the far field is investigated. Measurements of two-photon correlations under strong focusing are also presented and the special features thereof are discussed.
Spontaneous down conversion (SPDC) occurs in a nonlinear crystal when a pump photon splits in a pair of signal and idler photons. This paper demonstrates detection of single photons in low light level images with an electron multiplying CCD camera (EMCCD). The opposite spatial fluctuations of SPDC radiation are correlated in the quantum regime. Here, correlations between pixels are presented for collinear phase matching. The far field image of the parametric fluorescence is formed in the focal plane of a lens on a back-illuminated EMCCD. A thresholding procedure is applied on each image, in order to decide whether there is one or zero photo-electron on each pixel. We have experimentally demonstrated that spatial SPDC fluctuations between opposite pixels are quantum correlated in the far field.
Spontaneous parametric down-conversion (SPDC) is a widely used process to prepare entangled photon pairs. In SPDC, a second-order nonlinear crystal is pumped by a coherent laser beam to generate photon pairs. The photon pairs are usually detected by single-mode fibers (SMF), where only photons in a Gaussian mode can be collected. The collection modes possess typical Gaussian parameters, namely a beam waist and a focal plane position. The collection efficiency of photons highly depends on the choice of both parameters. The exact focal plane position of the pump beam relative to those of the detection modes is difficult to determine in a real experiment. Usually, theoretical and experimental studies assume that the focal plane positions of the pump and the generated beams are positioned in the center of the crystal. The displacement of beam focal planes can lead to deviations from expected results and the coupling efficiency into SMF can increase or decrease. In this work, we consider variable positions of focal planes and investigate how shifts of these focal planes influence the spatial and temporal properties of photon pairs. We present SPDC arrangements, in which the knowledge of the exact position of the focal planes is essential, as well as scenarios, where focal plane displacements do not contribute significantly to experimental outcomes. These findings are of particular interest for achieving higher efficiency in SPDC experiments.
Spontaneous Parametric Down-conversion (SPDC) is now routinely used to generate photon pairs for imaging, spectroscopy, and quantum information and metrology. However, the peculiar spectro-spatial properties of SPDC beams are not always known from the largest audience: they can give rise to ring-like beams, depending on the temperature, the wavelengths and pump focusing. This has to be considered for imaging or long-range applications. We will show examples of such beams created in 532-pumped PPLN or PPKTP and 1064-nm-pumped PPLN crystals. With a simple model of noncolinear phase matching we will give physical insight into the phenomena and explain the role of the signal/idler group delay. We will also explain how aperiodic crystals could be useful.
We performed a second-order spontaneous parametric down-conversion (SPDC) experiment in a Type II phase-matched KTiOPO4 crystal pumped at 532 nm giving birth to a signal beam at 1037 nm and an idler one at 1092 nm along the x-axis of the crystal. Three pump sources have been used: in the continuous-wave, nanosecond (200 ns, 1 kHz) and picosecond (15 ps, 10 Hz) regimes. That allowed us to cover a pump intensity range from 2.4 W.cm-2 to 3.7 GW.cm-2 which led to the generation of twin photons with a flux from 1.1x104 Hz to 1.2x1021 Hz, respectively, the corresponding quantum efficiencies being of 1.8x10-11 and 9.2x10-4. We identified two SPDC regimes regarding the pump intensity: one below 30 MW.cm-2 for which the flux increases linearly, and the other one above 30 MW.cm-2 for which the flux behaves exponentially. We proposed a semi-classical model under the undepleted pump approximation based on both the quantum fluctuations of vacuum for the seeding of the process and a propagation step ensured by classical fields, which allowed a satisfying description of these two regimes, with a much better agreement at high intensity than the quantum models based on the nonlinear momentum or the nonlinear Hamiltonian operators.
Coherence properties of the down-converted beams generated in spontaneous parametric down-conversion are investigated in detail using an iCCD camera. Experimental results are compared with those from a theoretical model developed for pulsed pumping with a Gaussian transverse profile. The results allow us to tailor the shape of correlation area of the signal and idler photons using pump-field and crystal parameters. As an example, splitting of a correlation area caused by a two-peak pump-field spectrum is experimentally studied.
Abstract Spontaneous parametric down-conversion (SPDC) is a widely used process to prepare entangled photon pairs. In SPDC, a second-order nonlinear crystal is pumped by a coherent laser beam to generate photon pairs. The photon pairs are usually detected by single-mode fibers (SMF), where only photons in a Gaussian mode can be collected. The collection modes possess typical Gaussian parameters, namely a beam waist and a focal plane position. The collection efficiency of photons highly depends on the choice of both parameters. The exact focal plane position of the pump beam relative to those of the detection modes is difficult to determine in a real experiment. Usually, theoretical and experimental studies assume that the focal plane positions of the pump and the generated beams are positioned in the center of the crystal. The displacement of beam focal planes can lead to deviations from expected results and the coupling efficiency into SMF can decrease. In this study, we theoretically examine variable positions of focal planes in the Laguerre–Gaussian basis, a popular experimental modal decomposition of the spatial biphoton state. We explore how the choice of focal plane positions affects the spatial and temporal properties and the purity of the photon pairs. We present SPDC setups where precise knowledge of the focal plane position is essential and scenarios where focal plane displacements have negligible impact on experimental outcomes. Graphical Abstract