Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Full field measurement of spatial correlated photon pairs with an EMCCD camera

M. Edgar, D. S. Tasca, Frauke Izdebski, Ryan E. Warburton, Gerald S. Buller, Jonathan Leach, Robert W. Boyd, Miles J. Padgett

Published Jan 1, 2012• 0 citations
OpenAlex

Abstract

The spatial correlations between the photon pairs produced by spontaneous parametric down conversion (SPDC) have been investigated in a number of different configurations over the last two decades (1). The high dimensionality of the transverse spatial degrees of freedom (DOF) of the photon pairs can be explored either by projections onto a discrete (infinite) basis, such as the LG modes, or by using a continuous basis defined by the transverse position or momentum of the photons. For instance, it has been shown that their transverse position and momentum display EPR-type correlations (2). Despite the continuous and unbounded nature of both these bases, the most common measurements to date have relied upon the scanning of a single avalanche photodiode or a very small number of individual detectors. This sequential scanning or small number of detectors negates any information capacity advantage in the use of spatial states. Recent years have seen a rapid advance in imaging technologies, particularly for low light levels. Of these technologies the highest quantum efficiency is achieved using electron multiplying CCDs (EMCCD). Developments in low noise EMCCD cameras suggest they are capable of greater than 80% quantum efficiencies and if operated in an ultra-low light environment whilst being maintained at low temperatures, can provide single photon sensitivity (3). EMCCDs have been used in measurements of sub-shot-noise correlations of intensity fluctuations (4, 5) as well as in intensity correlations measurements (6) in the far field of the photon pairs from SPDC. Here we report the observation of spatial correlations from SPDC using an EMCCD camera in both the image and far-field planes of the down conversion crystal. We pump a BBO crystal at 355nm with a few milli-Watts of optical power and use a simple lens system to relay the down-converted light to an EMCCD array which can be positioned in either the image plane or the far-field of the crystal. Our photon flux is around 1/100 per pixel, which approximately doubles the signal obtained when the light is blocked. We typically record 100,000 individual frames and then sum the auto-correlation of the individual frames. We observed intensity correlation and anti-correlation in the image and far-field planes, respectively. In both cases we make the correlations more visible by subtracting a background which is obtained as the average correlation obtained between successive frames. Using this approach we are able to visualize the strength of the correlations in both position and momentum, showing a variance product nearly one order of magnitude below the classical limit in both x and y directions.

Related papers

Purely spatial coincidences in parametric spontaneous down conversion

Jean-Luc Blanchet, F. Devaux, Luca Furfaro +1 more

Spontaneous down conversion (SPDC) occurs in a nonlinear crystal when a pump photon splits in a pair of signal and idler photons. This paper demonstrates detection of single photons in low light level images with an electron multiplying CCD camera (EMCCD). The opposite spatial fluctuations of SPDC radiation are correlated in the quantum regime. Here, correlations between pixels are presented for collinear phase matching. The far field image of the parametric fluorescence is formed in the focal plane of a lens on a back-illuminated EMCCD. A thresholding procedure is applied on each image, in order to decide whether there is one or zero photo-electron on each pixel. We have experimentally demonstrated that spatial SPDC fluctuations between opposite pixels are quantum correlated in the far field.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2009•0 citations

High-dimensional spatial entanglement observed with an electron multiplying CCD camera

D. S. Tasca, M. Edgar, Frauke Izdebski +6 more

Using an electron multiplying CCD camera we observe both image plane (position) and far field (momentum) correlations between photon pairs produced from spontaneous parametric down-conversion when using a 201 x 201 bi-dimensional array of pixels and a flux of around 0.02 photons/pixel. After background subtraction we characterize the strength of signal and idler correlations in both transverse dimensions by applying entanglement and EPR criteria, showing good agreement with the theoretical predictions. The application of such devices in quantum optics could have a wide range, including quantum computation with spatial degrees of freedom of single photons.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Nov 19, 2012•0 citations

A comparison between the measurement of quantum spatial correlations using qCMOS photon-number resolving and electron multiplying CCD camera technologies

K. Roberts, Osian Wolley, Thomas Gregory +1 more

Cameras with single-photon sensitivities can be used to measure the spatial correlations between the photon-pairs that are produced by parametric down-conversion. Even when pumped by a single-mode laser, the signal and idler photons are typically distributed over several thousand spatial modes yet strongly correlated with each other in their position and anti-correlated in their transverse momentum. These spatial correlations enable applications in imaging, sensing, communication, and optical processing. Here we show that, using a photon-number resolving camera, spatial correlations can be observed after only a few 10s of seconds of measurement time, thereby demonstrating comparable performance with previous single photon sensitive camera technologies but with the additional capability to resolve photon-number. Consequently, these photon-number resolving technologies are likely to find wide use in quantum, low-light, imaging systems.

Scientific Reports•Jun 26, 2024•11 citations

Image-Plane Detection of Spatially Entangled Photon Pairs with a CMOS Camera

David McFadden, Rainer Heintzmann

Spatially entangled photon pairs (biphotons) generated by spontaneous parametric down-conversion offer unique opportunities for quantum imaging, but image-plane biphoton correlations are difficult to observe with camera-based detectors. Previous camera-based biphoton imaging experiments have relied on photon-counting detection, which necessitates operation deep in the photon-sparse regime and requires extremely low dark rates. Here, we demonstrate the detection of spatial biphoton joint probability distributions in both the image plane and the pupil plane (also termed "near-field plane" and "far-field plane" respectively) using a conventional scientific CMOS camera operated in linear mode. We work at mesoscopic intensity levels, corresponding to a photon flux approximately four orders of magnitude higher than typical photon-counting approaches. From the measured image- and pupil plane correlations, we observe position and momentum correlations consistent with an EPR-type entanglement witness. A tailored correlation analysis suited for image plane imaging suppresses detector artifacts and intensity fluctuations, enabling acquisition with significantly fewer frames. Our results demonstrate that spatially entangled-light imaging can be performed efficiently with standard imaging hardware, extending quantum imaging techniques beyond the photon-counting regime.

quant-pharXiv:2512.24878•Jan 1, 2026•0 citations

Imaging high-dimensional spatial entanglement with a camera

M. Edgar, D. S. Tasca, Frauke Izdebski +6 more

The light produced by parametric down-conversion shows strong spatial entanglement that leads to violations of EPR criteria for separability. Historically, such studies have been performed by scanning a single-element, single-photon detector across a detection plane. Here we show that modern electron-multiplying charge-coupled device cameras can measure correlations in both position and momentum across a multi-pixel field of view. This capability allows us to observe entanglement of around 2,500 spatial states and demonstrate Einstein–Podolsky–Rosen type correlations by more than two orders of magnitude. More generally, our work shows that cameras can lead to important new capabilities in quantum optics and quantum information science. Measuring the entanglement between down-converted photons is central to many quantum optical experiments, and is normally performed by scanning detectors stepwise across a plane. Edgaret al. use a CCD camera to measure the entire entangled light field, finding strong correlations in position and momentum.

arXiv:1204.1293•Nature Communications•Aug 7, 2012•279 citations

Quantum correlations measured with multi-pixel detectors

Frauke Izdebski

use of any of the information contained in it must acknowledge this thesis as the source of the quotation or information. This thesis investigates the measurement of spatial correlations of photon pairs gener-ated through spontaneous parametric down-conversion with single-photon sensitive multi-pixel detectors. A custom designed and fabricated 8×1 fibre array detector for time to position multi-plexing was characterised. This detector was then commissioned in an experiment measuring the spatial correlations of photon pairs in position, momentum and in-termediate bases. The fibre array measured eight positions simultaneously with one Single-Photon Avalanche Diode, which led to an eight-fold increase in the data ac-quisition rate compared to traditional experiments, where a single SPAD was scanned across the detection plane. To capture all of the emitted light, an electron-multiplying CCD (EMCCD) camera was used. The spatial correlations were measured for the first time in momentum and pos-

•Aug 1, 2013•0 citations
The spatial correlations between the photon pairs produced by spontaneous parametric down conversion (SPDC) have been investigated in a number of different configurations over the last two decades (1). The high dimensionality of the transverse spatial degrees of freedom (DOF) of the photon pairs can be explored either by projections onto a discrete (infinite) basis, such as the LG modes, or by using a continuous basis defined by the transverse position or momentum of the photons. For instance, it has been shown that their transverse position and momentum display EPR-type correlations (2). Despite the continuous and unbounded nature of both these bases, the most common measurements to date have relied upon the scanning of a single avalanche photodiode or a very small number of individual detectors. This sequential scanning or small number of detectors negates any information capacity advantage in the use of spatial states. Recent years have seen a rapid advance in imaging technologies, particularly for low light levels. Of these technologies the highest quantum efficiency is achieved using electron multiplying CCDs (EMCCD). Developments in low noise EMCCD cameras suggest they are capable of greater than 80% quantum efficiencies and if operated in an ultra-low light environment whilst being maintained at low temperatures, can provide single photon sensitivity (3). EMCCDs have been used in measurements of sub-shot-noise correlations of intensity fluctuations (4, 5) as well as in intensity correlations measurements (6) in the far field of the photon pairs from SPDC. Here we report the observation of spatial correlations from SPDC using an EMCCD camera in both the image and far-field planes of the down conversion crystal. We pump a BBO crystal at 355nm with a few milli-Watts of optical power and use a simple lens system to relay the down-converted light to an EMCCD array which can be positioned in either the image plane or the far-field of the crystal. Our photon flux is around 1/100 per pixel, which approximately doubles the signal obtained when the light is blocked. We typically record 100,000 individual frames and then sum the auto-correlation of the individual frames. We observed intensity correlation and anti-correlation in the image and far-field planes, respectively. In both cases we make the correlations more visible by subtracting a background which is obtained as the average correlation obtained between successive frames. Using this approach we are able to visualize the strength of the correlations in both position and momentum, showing a variance product nearly one order of magnitude below the classical limit in both x and y directions.
Spontaneous down conversion (SPDC) occurs in a nonlinear crystal when a pump photon splits in a pair of signal and idler photons. This paper demonstrates detection of single photons in low light level images with an electron multiplying CCD camera (EMCCD). The opposite spatial fluctuations of SPDC radiation are correlated in the quantum regime. Here, correlations between pixels are presented for collinear phase matching. The far field image of the parametric fluorescence is formed in the focal plane of a lens on a back-illuminated EMCCD. A thresholding procedure is applied on each image, in order to decide whether there is one or zero photo-electron on each pixel. We have experimentally demonstrated that spatial SPDC fluctuations between opposite pixels are quantum correlated in the far field.
Using an electron multiplying CCD camera we observe both image plane (position) and far field (momentum) correlations between photon pairs produced from spontaneous parametric down-conversion when using a 201 x 201 bi-dimensional array of pixels and a flux of around 0.02 photons/pixel. After background subtraction we characterize the strength of signal and idler correlations in both transverse dimensions by applying entanglement and EPR criteria, showing good agreement with the theoretical predictions. The application of such devices in quantum optics could have a wide range, including quantum computation with spatial degrees of freedom of single photons.
Cameras with single-photon sensitivities can be used to measure the spatial correlations between the photon-pairs that are produced by parametric down-conversion. Even when pumped by a single-mode laser, the signal and idler photons are typically distributed over several thousand spatial modes yet strongly correlated with each other in their position and anti-correlated in their transverse momentum. These spatial correlations enable applications in imaging, sensing, communication, and optical processing. Here we show that, using a photon-number resolving camera, spatial correlations can be observed after only a few 10s of seconds of measurement time, thereby demonstrating comparable performance with previous single photon sensitive camera technologies but with the additional capability to resolve photon-number. Consequently, these photon-number resolving technologies are likely to find wide use in quantum, low-light, imaging systems.
Spatially entangled photon pairs (biphotons) generated by spontaneous parametric down-conversion offer unique opportunities for quantum imaging, but image-plane biphoton correlations are difficult to observe with camera-based detectors. Previous camera-based biphoton imaging experiments have relied on photon-counting detection, which necessitates operation deep in the photon-sparse regime and requires extremely low dark rates. Here, we demonstrate the detection of spatial biphoton joint probability distributions in both the image plane and the pupil plane (also termed "near-field plane" and "far-field plane" respectively) using a conventional scientific CMOS camera operated in linear mode. We work at mesoscopic intensity levels, corresponding to a photon flux approximately four orders of magnitude higher than typical photon-counting approaches. From the measured image- and pupil plane correlations, we observe position and momentum correlations consistent with an EPR-type entanglement witness. A tailored correlation analysis suited for image plane imaging suppresses detector artifacts and intensity fluctuations, enabling acquisition with significantly fewer frames. Our results demonstrate that spatially entangled-light imaging can be performed efficiently with standard imaging hardware, extending quantum imaging techniques beyond the photon-counting regime.
The light produced by parametric down-conversion shows strong spatial entanglement that leads to violations of EPR criteria for separability. Historically, such studies have been performed by scanning a single-element, single-photon detector across a detection plane. Here we show that modern electron-multiplying charge-coupled device cameras can measure correlations in both position and momentum across a multi-pixel field of view. This capability allows us to observe entanglement of around 2,500 spatial states and demonstrate Einstein–Podolsky–Rosen type correlations by more than two orders of magnitude. More generally, our work shows that cameras can lead to important new capabilities in quantum optics and quantum information science. Measuring the entanglement between down-converted photons is central to many quantum optical experiments, and is normally performed by scanning detectors stepwise across a plane. Edgaret al. use a CCD camera to measure the entire entangled light field, finding strong correlations in position and momentum.
use of any of the information contained in it must acknowledge this thesis as the source of the quotation or information. This thesis investigates the measurement of spatial correlations of photon pairs gener-ated through spontaneous parametric down-conversion with single-photon sensitive multi-pixel detectors. A custom designed and fabricated 8×1 fibre array detector for time to position multi-plexing was characterised. This detector was then commissioned in an experiment measuring the spatial correlations of photon pairs in position, momentum and in-termediate bases. The fibre array measured eight positions simultaneously with one Single-Photon Avalanche Diode, which led to an eight-fold increase in the data ac-quisition rate compared to traditional experiments, where a single SPAD was scanned across the detection plane. To capture all of the emitted light, an electron-multiplying CCD (EMCCD) camera was used. The spatial correlations were measured for the first time in momentum and pos-