Applied Physics Letters

Picovoltmeter based on a high transition temperature SQUID

A. H. Miklich, D. Koelle, Frank Ludwig, D. T. Nemeth, E. Dantsker, John L. Clarke

Published Jan 9, 1995• 25 citations
Publisher

Abstract

We have fabricated and tested picovoltmeters in which the voltage source is connected in series with a calibrated resistor and a coil inductively coupled to a high-transition temperature superconducting quantum interference device operating at 77 K. The coil consists of either seven or ten turns of copper wire or of two turns patterned in a film of YBa2Cu3O7−x(YBCO). The lowest voltage noise achieved at 1 Hz was 30 pV Hz−1/2 and 2.3 pV Hz−1/2 for input coils made of copper and YBCO, respectively.

DOI
10.1063/1.113555

Related papers

A broadband picovoltmeter based on the direct current superconducting quantum interference device with additional positive feedback

Vladimir Polushkin, D. Drung, H. Koch

A picovoltmeter working at 4.2 K and based on a direct current superconducting quantum interference device (dc SQUID) with additional passive positive feedback for investigating the properties of superconducting thin films, Josephson junctions, and SQUIDs has been developed. It has a large small-signal bandwidth fm≂800 kHz, a slew rate of ≂38 mV/s, a dynamic range of 146 dB, and a voltage resolution of 5 pV/Hz1/2 for a signal source impedance Rs=0 Ω. The noise temperature is ≂0.6 K for Rs=1 Ω. In this article the dynamics and noise properties of the instrument are discussed.

Review of Scientific Instruments•Sep 1, 1994•18 citations

High-Tc super conducting quantum interference devices with slots or holes: Low 1/f noise in ambient magnetic fields

E. Dantsker, Saburo Tanaka, John L. Clarke

High-transition temperature dc superconducting quantum interference devices (SQUIDs) have been fabricated with arrays of slots or holes patterned in the 186×204 μm2 washers. In two designs, with seven slots or 248 holes, the linewidth of the remaining YBa2Cu3O7−x film was 4 μm. These devices exhibited virtually no increase in their low-frequency noise when they were cooled in static magnetic fields up to a certain threshold, above 100 μT in the best case. Furthermore, the mutual inductance between these devices and a seven-turn, spiral coil was at least 85% of that for a solid SQUID with the same outer dimensions.

Applied Physics Letters•Apr 14, 1997•168 citations

Substrate step-edge YBa2Cu3O7 rf SQUIDs

K.P. Daly, William D. Dozier, John F. Burch +4 more

We have developed a technique which permits high-yield fabrication of microbridges and low noise YBa2Cu3O7 superconducting quantum interference devices (SQUIDs) in epitaxial thin films. These SQUIDs operate over a wide temperature range extending from 4 K to close to the superconducting transition temperature. Measurements of an rf SQUID operating at 77 K give a peak-to-peak flux sensitivity of 36 μV/Φ0 and a flux noise at 10 Hz of 1.5× 10−4 Φ0/√Hz. Device yields over 80% have been obtained.

Applied Physics Letters•Feb 4, 1991•133 citations

High-temperature dc superconducting quantum interference device with deep-submicron YBa2Cu3O7 weak links

Suzanne E. Romaine, Paul M. Mankiewich, William J. Skocpol +1 more

We have fabricated a YBa2Cu3O7 (YBCO) thin-film dc superconducting quantum interference device (SQUID) with lithographically defined deep-submicron weak links. At 77 K the voltage response to dc flux is sinusoidal and nonhysteretic, with maximum peak-to-peak amplitude of 5 μV. The maximum response is 8 μV at 70 K, where 2LI0/Φ0≊1. At lower temperatures, the maximum response oscillates in the range 4–6 μV. Random telegraph noise was observed near 30–40 K. Well-behaved Shapiro steps were observable at all measured temperatures below Tc.

Applied Physics Letters•Nov 11, 1991•5 citations

Micro-superconducting quantum interference devices based on V/Cu/V Josephson nanojunctions

Alberto Ronzani, Matthieu Baillergeau, Carles Altimiras +1 more

We report on the fabrication and characterization of micrometer-sized superconducting quantum interference devices (SQUIDs) based on nanoscale vanadium/copper/vanadium Josephson weak links. Magnetically driven quantum interference patterns have been measured for temperatures in the 0.24–2 K range. As DC SQUIDs, these devices obtain flux-to-voltage transfer function values as high as 450 μV/Φ0 leading to promising magnetic flux resolution ΦN<3 μΦ0/Hz, being here limited by the room temperature preamplification stage. Significant improvement in the flux noise performance figures is expected with the adoption of cryogenic preamplification. The presented devices are suitable for operation as small-area SQUIDs at sub-Kelvin temperature, but their design can also be upscaled to include input coils enabling their use as sensitive magnetometers via the adoption of optimized electronic readout stages based on flux feedback schemes.

arXiv:1305.3863•Applied Physics Letters•Jul 29, 2013•27 citations

Low-noise tunnel junction dc SQUID’s

Michael W. Cromar, P. Carelli

We present the results of an investigation of thin-film dc super conducting quantum interference device (SQUID’s) with very high energy resolution. The SQUID’s were fabricated using integrated-circuit techniques appropriate for superconducting devices. A weakly coupled SQUID with very low inductance (1 pH) had an intrinsic energy sensitivity 6×10−34 J/Hz = 0.9 h. A well-coupled SQUID (coupling constant α = 0.43) had an energy sensitivity referred to the input coil of 4.7×10−32 J/Hz = 71 h.

Applied Physics Letters•May 1, 1981•86 citations
We have fabricated and tested picovoltmeters in which the voltage source is connected in series with a calibrated resistor and a coil inductively coupled to a high-transition temperature superconducting quantum interference device operating at 77 K. The coil consists of either seven or ten turns of copper wire or of two turns patterned in a film of YBa2Cu3O7−x(YBCO). The lowest voltage noise achieved at 1 Hz was 30 pV Hz−1/2 and 2.3 pV Hz−1/2 for input coils made of copper and YBCO, respectively.
A picovoltmeter working at 4.2 K and based on a direct current superconducting quantum interference device (dc SQUID) with additional passive positive feedback for investigating the properties of superconducting thin films, Josephson junctions, and SQUIDs has been developed. It has a large small-signal bandwidth fm≂800 kHz, a slew rate of ≂38 mV/s, a dynamic range of 146 dB, and a voltage resolution of 5 pV/Hz1/2 for a signal source impedance Rs=0 Ω. The noise temperature is ≂0.6 K for Rs=1 Ω. In this article the dynamics and noise properties of the instrument are discussed.
High-transition temperature dc superconducting quantum interference devices (SQUIDs) have been fabricated with arrays of slots or holes patterned in the 186×204 μm2 washers. In two designs, with seven slots or 248 holes, the linewidth of the remaining YBa2Cu3O7−x film was 4 μm. These devices exhibited virtually no increase in their low-frequency noise when they were cooled in static magnetic fields up to a certain threshold, above 100 μT in the best case. Furthermore, the mutual inductance between these devices and a seven-turn, spiral coil was at least 85% of that for a solid SQUID with the same outer dimensions.
We have developed a technique which permits high-yield fabrication of microbridges and low noise YBa2Cu3O7 superconducting quantum interference devices (SQUIDs) in epitaxial thin films. These SQUIDs operate over a wide temperature range extending from 4 K to close to the superconducting transition temperature. Measurements of an rf SQUID operating at 77 K give a peak-to-peak flux sensitivity of 36 μV/Φ0 and a flux noise at 10 Hz of 1.5× 10−4 Φ0/√Hz. Device yields over 80% have been obtained.
We have fabricated a YBa2Cu3O7 (YBCO) thin-film dc superconducting quantum interference device (SQUID) with lithographically defined deep-submicron weak links. At 77 K the voltage response to dc flux is sinusoidal and nonhysteretic, with maximum peak-to-peak amplitude of 5 μV. The maximum response is 8 μV at 70 K, where 2LI0/Φ0≊1. At lower temperatures, the maximum response oscillates in the range 4–6 μV. Random telegraph noise was observed near 30–40 K. Well-behaved Shapiro steps were observable at all measured temperatures below Tc.
We report on the fabrication and characterization of micrometer-sized superconducting quantum interference devices (SQUIDs) based on nanoscale vanadium/copper/vanadium Josephson weak links. Magnetically driven quantum interference patterns have been measured for temperatures in the 0.24–2 K range. As DC SQUIDs, these devices obtain flux-to-voltage transfer function values as high as 450 μV/Φ0 leading to promising magnetic flux resolution ΦN<3 μΦ0/Hz, being here limited by the room temperature preamplification stage. Significant improvement in the flux noise performance figures is expected with the adoption of cryogenic preamplification. The presented devices are suitable for operation as small-area SQUIDs at sub-Kelvin temperature, but their design can also be upscaled to include input coils enabling their use as sensitive magnetometers via the adoption of optimized electronic readout stages based on flux feedback schemes.
We present the results of an investigation of thin-film dc super conducting quantum interference device (SQUID’s) with very high energy resolution. The SQUID’s were fabricated using integrated-circuit techniques appropriate for superconducting devices. A weakly coupled SQUID with very low inductance (1 pH) had an intrinsic energy sensitivity 6×10−34 J/Hz = 0.9 h. A well-coupled SQUID (coupling constant α = 0.43) had an energy sensitivity referred to the input coil of 4.7×10−32 J/Hz = 71 h.