Review of Scientific Instruments

A broadband picovoltmeter based on the direct current superconducting quantum interference device with additional positive feedback

Vladimir Polushkin, D. Drung, H. Koch

Published Sep 1, 1994• 18 citations
Publisher

Abstract

A picovoltmeter working at 4.2 K and based on a direct current superconducting quantum interference device (dc SQUID) with additional passive positive feedback for investigating the properties of superconducting thin films, Josephson junctions, and SQUIDs has been developed. It has a large small-signal bandwidth fm≂800 kHz, a slew rate of ≂38 mV/s, a dynamic range of 146 dB, and a voltage resolution of 5 pV/Hz1/2 for a signal source impedance Rs=0 Ω. The noise temperature is ≂0.6 K for Rs=1 Ω. In this article the dynamics and noise properties of the instrument are discussed.

DOI
10.1063/1.1144593

Related papers

Temperature-dependent performance of all-NbN DC-SQUID magnetometers

Quansheng Liu, Huiwu Wang, Qiyu Zhang +3 more

Integrated NbN direct current superconducting quantum interference device (DC-SQUID) magnetometers were developed based on high-quality epitaxial NbN/AlN/NbN Josephson junctions for SQUID applications operating at high temperatures. We report the current–voltage and voltage–flux characteristics and the noise performance of the NbN DC-SQUIDs for temperatures ranging from 4.2 to 9 K. The critical current and voltage swing of the DC-SQUIDs decreased by 15% and 25%, respectively, as the temperature was increased from 4.2 to 9 K. The white flux noise of the DC-SQUID magnetometer at 1 kHz increased from 3.9 μΦ0/Hz1/2 at 4.2 K to 4.8 μΦ0/Hz1/2 at 9 K with 23% increase, corresponding to the magnetic field noise of 6.6 and 8.1 fT/Hz1/2, respectively. The results show that NbN DC-SQUIDs improve the tolerance of the operating temperatures and temperature fluctuations in SQUID applications.

Applied Physics Letters•May 29, 2017•18 citations

An all thin-film resistive DC SQUID-a current-controlled oscillator

G.S. Krivoy, H. Koch

An all thin-film resistive SQUID with two Josephson tunnel junctions has been designed, fabricated and studied. As well as the two junctions, this device consists of a low ohmic (1.9*10 -6 Omega ) resistive part connected by superconducting leads to both junctions in a loop with very low ( approximately 10 -11 H) inductance. A direct current flowing through the resistive part fixes the voltage difference between the two Josephson junctions that are additionally fed by a bias current. The voltage difference is converted into a signal frequency that can be picked up from the SQUID with a conversion factor of ( phi o ) -1 =483.6 MHz mu V -1 , defined only by the electron charge and Planck's constant. An output signal level (peak-to-peak) of about 50 mu V has been obtained. The low frequency range (below 100 kHz) of the output signal frequency has been investigated. The possibilities of considerably extending this frequency range are also discussed.

Superconductor Science and Technology•Oct 1, 1992•14 citations

Picovoltmeter based on a high transition temperature SQUID

A. H. Miklich, D. Koelle, Frank Ludwig +3 more

We have fabricated and tested picovoltmeters in which the voltage source is connected in series with a calibrated resistor and a coil inductively coupled to a high-transition temperature superconducting quantum interference device operating at 77 K. The coil consists of either seven or ten turns of copper wire or of two turns patterned in a film of YBa2Cu3O7−x(YBCO). The lowest voltage noise achieved at 1 Hz was 30 pV Hz−1/2 and 2.3 pV Hz−1/2 for input coils made of copper and YBCO, respectively.

Applied Physics Letters•Jan 9, 1995•25 citations

Very low noise, tightly coupled, dc SQUID amplifiers

B. Muhlfelder, J. A. Beall, Michael W. Cromar +1 more

We have fabricated and tested thin film, niobium edge junction, double transformer, dc superconducting quantum interference devices (SQUID’s) that were stable under room-temperature storage and thermal cycling and that had very good noise performance. The input inductance, approximately 1.7 μH, was large enough to facilitate good matching to many experiments. When the SQUID was operated as a small-signal amplifier, the minimum detectable energy per unit bandwidth (Se) was 5×10−33 J/Hz at 100 kHz, referred to the SQUID loop (uncoupled). The minimum detectable energy per unit bandwidth was 1.8×10−31 J/Hz at 100 kHz, referred to the input coil. The SQUID’s had good characteristics for flux-locked operation since the small signal Se was low over a substantial range of bias current and magnetic flux. For operation in a flux-locked feedback circuit, Se was 6×10−32 J/Hz at 1 kHz.

Applied Physics Letters•Oct 27, 1986•19 citations

Low-noise ultra-high-speed dc SQUID readout electronics

D. Drung, Colmar Hinnrichs, H.-J. Barthelmess

User-friendly ultra-high-speed readout electronics for dc superconducting quantum interference devices (SQUIDs) are presented. To maximize the system bandwidth, the SQUID is directly read out without flux modulation. A composite preamplifier is used consisting of a slow dc amplifier in parallel with a fast ac amplifier. In this way, excellent dc precision and a high amplifier bandwidth of 50 MHz are achieved, simultaneously. A virtual 50 Ω amplifier input resistance with negligible excess noise is realized by active shunting, i.e., by applying feedback from preamplifier output to input via a high resistance. The white voltage and current noise levels are 0.33 nV Hz −1 and 2.6 pA Hz −1/2 , respectively. The electronics is fully computer controlled via a microcontroller integrated into the flux-locked loop (FLL) board. Easy-to-use software makes the various electronic settings accessible. A wide bias voltage range of 1.3 mV enables the readout of series SQUID arrays. Furthermore, additional current sources allow the operation of two-stage SQUIDs or transition edge sensors. The electronics was tested using various SQUIDs with input inductances between 30 nH and 1.5 µH. Typically, the maximum FLL bandwidth was 20 MHz, which is close to the theoretical limit given by transmission line delay within the FLL. Slew rates of up to 4.6 Φ 0 µs −1 were achieved with series SQUID arrays. Current noise levels as low as 0.47 pA Hz −1/2 and coupled energy sensitivities between 90 h and 500 h were measured at 4.2 K, where h is the Planck constant. The noise did not degrade when the system bandwidth was increased to the maximum value of about 20 MHz. With a two-stage set-up, intrinsic white energy sensitivities of 30 h and 2.3 h were measured at 4.2 and 0.3 K, respectively.

Superconductor Science and Technology•Feb 27, 2006•76 citations

Broadband SQUID amplifiers for photonic applications

Vladimir Polushkin, D. Glowacka, R. Hart +1 more

The dynamics and noise of a dc SQUID (the Superconducting Quantum Interference Device), with the McCumber parameter /spl beta//sub c/=2/spl pi/R/sup 2/l/sub c/C//spl Phi//sub 0/ close to the unity (where I/sub c/, R, C is the critical current, the shunt resistance and the capacitance of the Josephson junctions comprising the SQUID, respectively, /spl Phi//sub 0/=2.07 10/sup -15/ Wb is the magnetic flux quantum) integrated with a planar spiral input coil, have been experimentally studied. The length of the spiral input coil was chosen so as to match its /spl lambda//4 microwave resonance frequency to the plasma resonance frequency of the SQUID. The input coil resonance is found to enhance the overall quality factor Q of the Josephson oscillations in the SQUID and, as a result, to increase the dynamic resistance R/sub d/ and the gradient of the flux-to-voltage characteristics, /spl delta/V//spl delta//spl Phi/, without hysteresis. A dc SQUID with a loop inductance L=30.5 pH, /spl beta//sub c/=0.72, and a 6 turn input coil demonstrated a non-distorted quasi-sinusoidal flux-to-voltage transfer function with an exceptionally large modulation depth of 140 /spl mu/V peak-to-peak. The spectral density of the magnetic flux noise was as low as 3.5/spl times/10/sup -7/ /spl Phi//sub 0//Hz/sup 1/2/ in the double stage configuration, measured at a temperature 4.2 K using direct read out electronics. In combination with an intermediary transformer, the current resolution of the SQUID is as low as 1.25 pA/Hz/sup 1/2/ with an input coil inductance of 100 nH.

IEEE Transactions on Applied Superconductivity•Jun 1, 1999•1 citation
A picovoltmeter working at 4.2 K and based on a direct current superconducting quantum interference device (dc SQUID) with additional passive positive feedback for investigating the properties of superconducting thin films, Josephson junctions, and SQUIDs has been developed. It has a large small-signal bandwidth fm≂800 kHz, a slew rate of ≂38 mV/s, a dynamic range of 146 dB, and a voltage resolution of 5 pV/Hz1/2 for a signal source impedance Rs=0 Ω. The noise temperature is ≂0.6 K for Rs=1 Ω. In this article the dynamics and noise properties of the instrument are discussed.
Integrated NbN direct current superconducting quantum interference device (DC-SQUID) magnetometers were developed based on high-quality epitaxial NbN/AlN/NbN Josephson junctions for SQUID applications operating at high temperatures. We report the current–voltage and voltage–flux characteristics and the noise performance of the NbN DC-SQUIDs for temperatures ranging from 4.2 to 9 K. The critical current and voltage swing of the DC-SQUIDs decreased by 15% and 25%, respectively, as the temperature was increased from 4.2 to 9 K. The white flux noise of the DC-SQUID magnetometer at 1 kHz increased from 3.9 μΦ0/Hz1/2 at 4.2 K to 4.8 μΦ0/Hz1/2 at 9 K with 23% increase, corresponding to the magnetic field noise of 6.6 and 8.1 fT/Hz1/2, respectively. The results show that NbN DC-SQUIDs improve the tolerance of the operating temperatures and temperature fluctuations in SQUID applications.
An all thin-film resistive SQUID with two Josephson tunnel junctions has been designed, fabricated and studied. As well as the two junctions, this device consists of a low ohmic (1.9*10 -6 Omega ) resistive part connected by superconducting leads to both junctions in a loop with very low ( approximately 10 -11 H) inductance. A direct current flowing through the resistive part fixes the voltage difference between the two Josephson junctions that are additionally fed by a bias current. The voltage difference is converted into a signal frequency that can be picked up from the SQUID with a conversion factor of ( phi o ) -1 =483.6 MHz mu V -1 , defined only by the electron charge and Planck's constant. An output signal level (peak-to-peak) of about 50 mu V has been obtained. The low frequency range (below 100 kHz) of the output signal frequency has been investigated. The possibilities of considerably extending this frequency range are also discussed.
We have fabricated and tested picovoltmeters in which the voltage source is connected in series with a calibrated resistor and a coil inductively coupled to a high-transition temperature superconducting quantum interference device operating at 77 K. The coil consists of either seven or ten turns of copper wire or of two turns patterned in a film of YBa2Cu3O7−x(YBCO). The lowest voltage noise achieved at 1 Hz was 30 pV Hz−1/2 and 2.3 pV Hz−1/2 for input coils made of copper and YBCO, respectively.
We have fabricated and tested thin film, niobium edge junction, double transformer, dc superconducting quantum interference devices (SQUID’s) that were stable under room-temperature storage and thermal cycling and that had very good noise performance. The input inductance, approximately 1.7 μH, was large enough to facilitate good matching to many experiments. When the SQUID was operated as a small-signal amplifier, the minimum detectable energy per unit bandwidth (Se) was 5×10−33 J/Hz at 100 kHz, referred to the SQUID loop (uncoupled). The minimum detectable energy per unit bandwidth was 1.8×10−31 J/Hz at 100 kHz, referred to the input coil. The SQUID’s had good characteristics for flux-locked operation since the small signal Se was low over a substantial range of bias current and magnetic flux. For operation in a flux-locked feedback circuit, Se was 6×10−32 J/Hz at 1 kHz.
User-friendly ultra-high-speed readout electronics for dc superconducting quantum interference devices (SQUIDs) are presented. To maximize the system bandwidth, the SQUID is directly read out without flux modulation. A composite preamplifier is used consisting of a slow dc amplifier in parallel with a fast ac amplifier. In this way, excellent dc precision and a high amplifier bandwidth of 50 MHz are achieved, simultaneously. A virtual 50 Ω amplifier input resistance with negligible excess noise is realized by active shunting, i.e., by applying feedback from preamplifier output to input via a high resistance. The white voltage and current noise levels are 0.33 nV Hz −1 and 2.6 pA Hz −1/2 , respectively. The electronics is fully computer controlled via a microcontroller integrated into the flux-locked loop (FLL) board. Easy-to-use software makes the various electronic settings accessible. A wide bias voltage range of 1.3 mV enables the readout of series SQUID arrays. Furthermore, additional current sources allow the operation of two-stage SQUIDs or transition edge sensors. The electronics was tested using various SQUIDs with input inductances between 30 nH and 1.5 µH. Typically, the maximum FLL bandwidth was 20 MHz, which is close to the theoretical limit given by transmission line delay within the FLL. Slew rates of up to 4.6 Φ 0 µs −1 were achieved with series SQUID arrays. Current noise levels as low as 0.47 pA Hz −1/2 and coupled energy sensitivities between 90 h and 500 h were measured at 4.2 K, where h is the Planck constant. The noise did not degrade when the system bandwidth was increased to the maximum value of about 20 MHz. With a two-stage set-up, intrinsic white energy sensitivities of 30 h and 2.3 h were measured at 4.2 and 0.3 K, respectively.
The dynamics and noise of a dc SQUID (the Superconducting Quantum Interference Device), with the McCumber parameter /spl beta//sub c/=2/spl pi/R/sup 2/l/sub c/C//spl Phi//sub 0/ close to the unity (where I/sub c/, R, C is the critical current, the shunt resistance and the capacitance of the Josephson junctions comprising the SQUID, respectively, /spl Phi//sub 0/=2.07 10/sup -15/ Wb is the magnetic flux quantum) integrated with a planar spiral input coil, have been experimentally studied. The length of the spiral input coil was chosen so as to match its /spl lambda//4 microwave resonance frequency to the plasma resonance frequency of the SQUID. The input coil resonance is found to enhance the overall quality factor Q of the Josephson oscillations in the SQUID and, as a result, to increase the dynamic resistance R/sub d/ and the gradient of the flux-to-voltage characteristics, /spl delta/V//spl delta//spl Phi/, without hysteresis. A dc SQUID with a loop inductance L=30.5 pH, /spl beta//sub c/=0.72, and a 6 turn input coil demonstrated a non-distorted quasi-sinusoidal flux-to-voltage transfer function with an exceptionally large modulation depth of 140 /spl mu/V peak-to-peak. The spectral density of the magnetic flux noise was as low as 3.5/spl times/10/sup -7/ /spl Phi//sub 0//Hz/sup 1/2/ in the double stage configuration, measured at a temperature 4.2 K using direct read out electronics. In combination with an intermediary transformer, the current resolution of the SQUID is as low as 1.25 pA/Hz/sup 1/2/ with an input coil inductance of 100 nH.