We show that the performance of continuous-variable measurement-device-independent quantum key distribution will decline dramatically when considering detector’s imperfections. However, it can be improved by using phase sensitive optical amplifiers.
Abstract. The imperfections of a receiver’s detector affect the performance of two-way continuous-variable quantum key distribution protocols and are difficult to adjust in practical situations. We propose a method to improve the performance of two-way continuous-variable quantum key distribution by adding a parameter-adjustable optical amplifier at the receiver. A security analysis is derived against a two-mode collective entangling cloner attack. Our simulations show that the proposed method can improve the performance of protocols as long as the inherent noise of the amplifier is lower than a critical value, defined as the tolerable amplifier noise. Furthermore, the optimal performance can approach the scenario where a perfect detector is used.
Measurement-device-independent quantum key distribution removes all detector-side attacks in quantum cryptography, and in the meantime doubles the secure distance. The source side, however, is still vulnerable to various attacks. In particular, the continuous phase randomization assumption on the source side is normally not fulfilled in experimental implementation and may potentially open a loophole. In this work, we first show that indeed there are loopholes for imperfect phase randomization in measurement-device-independent quantum key distribution by providing a concrete attack. Then we propose a discrete-phase-randomized measurement-device-independent quantum key distribution protocol as a solution to close this source-side loophole.
The measurement-device-independent quantum key distribution (MDI-QKD) protocol is immune to imperfect measurement devices. However, its practicality and performance when implemented in continuous-variable (CV) mode are still not satisfactory. We propose a CV-MDI-QKD protocol based on modulated squeezed states, and analyze its security against two-mode Gaussian attack. The results show that the protocol can achieve a higher secret key rate and transmission distance than previous coherent-state and squeezed-state protocols. A method to compensate the imperfection of a practical homodyne detector using phase-sensitive optical amplifiers is also presented. By setting an appropriate optical amplification gain, realistic detectors with ordinary quantum efficiency can be employed. In addition, we discuss the impact of finite-size effects on the secret key rate of the protocol. The methods presented may aid in the practical application of the CV-MDI-QKD protocol.