Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Continuous-variable measurement-device-independent quantum key distribution using modulated squeezed states and optical amplifiers

Pu Wang, Xuyang Wang, Yongmin Li

Published Apr 3, 2019• 35 citations
Publisher

Abstract

The measurement-device-independent quantum key distribution (MDI-QKD) protocol is immune to imperfect measurement devices. However, its practicality and performance when implemented in continuous-variable (CV) mode are still not satisfactory. We propose a CV-MDI-QKD protocol based on modulated squeezed states, and analyze its security against two-mode Gaussian attack. The results show that the protocol can achieve a higher secret key rate and transmission distance than previous coherent-state and squeezed-state protocols. A method to compensate the imperfection of a practical homodyne detector using phase-sensitive optical amplifiers is also presented. By setting an appropriate optical amplification gain, realistic detectors with ordinary quantum efficiency can be employed. In addition, we discuss the impact of finite-size effects on the secret key rate of the protocol. The methods presented may aid in the practical application of the CV-MDI-QKD protocol.

DOI
10.1103/physreva.99.042309

Related papers

Phase-Matching Continuous-Variable Measurement-Device-Independent Quantum Key Distribution

Peng Huang, Tao Wang, Duan Huang +1 more

Continuous-variable measurement-device-independent quantum key distribution (CV-MDI-QKD) allows remote parties to share information-theoretical secure keys while defending all the side-channel attacks on measurement devices. However, the secure transmission distance and the secret key rate are quite limited due to the high untrusted equivalent excess noise in the Gaussian modulation. More particularly, extremely high-efficiency homodyne detections are required for even non-zero secure transmission distances, which directly restrict its practical realization. Here, we propose a CV-MDI-QKD protocol by encoding the key information into matched discrete phases of two groups of coherent states, which decreases the required detection efficiency for ideally asymmetric cases, and makes it possible to practically achieve secure key distribution with current low-efficiency homodyne detections. Besides, a proof-of-principle experiment with a locally generated oscillator is implemented, which, for the first time, demonstrates the realizability of CV-MDI-QKD using all fiber-based devices. The discrete-modulated phase-matching method provides an alternative direction of an applicable quantum key distribution with practical security.

Symmetry•Mar 13, 2022•2 citations

Simultaneous measurement-device-independent continuous variable quantum key distribution with realistic detector compensation

Xiaodong Wu, Yi-Jun Wang, Duan Huang +1 more

We propose a novel scheme for measurement-device-independent (MDI) continuous-variable quantum key distribution (CVQKD) by simultaneously conducting classical communication and QKD, which is called “simultaneous MDI-CVQKD” protocol. In such protocol, each sender (Alice, Bob) can superimpose random numbers for QKD on classical information by taking advantage of the same weak coherent pulse and an untrusted third party (Charlie) decodes it by using the same coherent detectors, which could be appealing in practice due to that multiple purposes can be realized by employing only single communication system. What is more, the proposed protocol is MDI, which is immune to all possible side-channel attacks on practical detectors. Security results illustrate that the simultaneous MDI-CVQKD protocol can secure against arbitrary collective attacks. In addition, we employ phase-sensitive optical amplifiers to compensate the imperfection existing in practical detectors. With this technology, even common practical detectors can be used for detection through choosing a suitable optical amplifier gain. Furthermore, we also take the finite-size effect into consideration and show that the whole raw keys can be taken advantage of to generate the final secret key instead of sacrificing part of them for parameter estimation. Therefore, an enhanced performance of the simultaneous MDI-CVQKD protocol can be obtained in finite-size regime.

Frontiers of Physics•Mar 6, 2020•16 citations

Impact of Imbalanced Modulation on Security of Continuous-Variable Measurement-Device-Independent Quantum Key Distribution

Wenyuan Liu, Zehui Liu, Jiandong Bai +4 more

Continuous variable measurement-device-independent quantum key distribution (CV-MDI-QKD) removes all known or unknown side-channel attacks on detectors. However, it is difficult to fully implement assumptions in the security demonstration model, which leads to potential security vulnerabilities inevitably existing in the practical system. In this paper, we explore the impact of imbalanced modulation at transmitters on the security of the CV-MDI-QKD system mainly using a coherent state and squeezed state under symmetric and asymmetric distances. Assuming two different modulation topologies of senders, we propose a generalized theoretical scheme and evaluate the key parameter achievable of the protocol with the mechanism of imbalanced modulation. The presented results show that imbalanced modulation can achieve a relatively nonlinearly higher secret key rate and transmission distances than the previous protocol which is the balanced modulation variance used by transmitters. The advantage of imbalanced modulation is demonstrated for the system key parameter estimation using numerical simulation under different situations. In addition, the consequences indicate the importance of imbalanced modulation on the performance of CV-MDI-QKD protocol and provide a theoretical framework for experimental implementation as well as the optimal modulated mode.

Photonics•Jul 10, 2024•1 citation

Continuous-variable measurement-device-independent quantum key distribution with source-intensity errors

Pu Wang, Xuyang Wang, Yongmin Li

Continuous-variable measurement-device-independent quantum key distribution (CV-MDI-QKD) is immune to all detector side channel attacks, however its security requires trusted sources. We investigate the effects of source intensity errors, the most crucial source error, on the security of CV-MDI-QKD protocol with Gaussian-modulated coherent states. We establish a general source intensity errors model and derive the secret key rate based on different assumptions on the abilities of legal parties Alice and Bob. To avoid the adverse effects of the sources' intensity errors on CV-MDI-QKD, we present different data-processing schemes. We also assess the security of the protocol against collective Gaussian attacks in the finite-size scenario with composable security. Taking source intensity errors into consideration, we achieve improved security compared to previous demonstrations. Our results will provide a useful reference for practical implementations of CV-MDI-QKD.

Physical Review A•Aug 10, 2020•11 citations

Continuous-variable measurement-device-independent quantum key distribution with multi-ring discrete modulation

Chengji Liu, Yu Chao, Lu Wang +1 more

We propose a continuous-variable measurement-device-independent quantum key distribution with multi-ring discrete modulation (MR-CV-MDI-QKD) protocol. In our scheme, coherent states are allocated across distinct rings (amplitudes) in the phase space, and each ring is subjected to traditional M-symbol phase shift keying (MPSK) modulation. The analysis and simulation are given to demonstrate the security of our scheme under collective attacks. The results show that, compared with the traditional discrete modulated (DM)-CV-MDI-QKD where only the MPSK is used for modulation with a fixed amplitude, MR-CV-MDI-QKD can decrease the upper bound of the information accessible to an eavesdropper, thereby facilitating an extended transmission distance and increasing the secret key rate, furthermore, it exhibits a higher tolerance to diminished reverse reconciliation efficiency. This work provides an effective way for the practical implementation of the CV-MDI-QKD protocol.

Optics Express•Aug 9, 2024•6 citations

Continuous-Variable Measurement-Device-Independent Quantum Key Distribution in the Terahertz Band

Hao-Xin Liu, Zhe Yang, Shuoyu Yang +2 more

We have introduced, for the first time, a protocol for Continuous-Variable Measurement-Device-Independent Quantum Key Distribution (CV-MDI-QKD) in the terahertz (THz) frequency band. We have conducted a secret key rate analysis against collective attacks. The proposed THz CV-MDI-QKD is immune to all detector attacks, significantly enhancing the security assurance of practical THz CVQKD implementations. Furthermore, we investigated the impact of finite key length (the finite-size effect) and finite reconciliation efficiency on the performance of practical THz CV-MDI-QKD systems. Our findings reveal that by employing a large number of keys or signals and optimizing the modulation variance, the detrimental effects arising from the finite-size effect and suboptimal reconciliation efficiency can be notably mitigated. These insights play a crucial role in advancing the feasibility of THz CVQKD technology towards practical applications.

Photonics•Apr 15, 2024•3 citations
The measurement-device-independent quantum key distribution (MDI-QKD) protocol is immune to imperfect measurement devices. However, its practicality and performance when implemented in continuous-variable (CV) mode are still not satisfactory. We propose a CV-MDI-QKD protocol based on modulated squeezed states, and analyze its security against two-mode Gaussian attack. The results show that the protocol can achieve a higher secret key rate and transmission distance than previous coherent-state and squeezed-state protocols. A method to compensate the imperfection of a practical homodyne detector using phase-sensitive optical amplifiers is also presented. By setting an appropriate optical amplification gain, realistic detectors with ordinary quantum efficiency can be employed. In addition, we discuss the impact of finite-size effects on the secret key rate of the protocol. The methods presented may aid in the practical application of the CV-MDI-QKD protocol.
Continuous-variable measurement-device-independent quantum key distribution (CV-MDI-QKD) allows remote parties to share information-theoretical secure keys while defending all the side-channel attacks on measurement devices. However, the secure transmission distance and the secret key rate are quite limited due to the high untrusted equivalent excess noise in the Gaussian modulation. More particularly, extremely high-efficiency homodyne detections are required for even non-zero secure transmission distances, which directly restrict its practical realization. Here, we propose a CV-MDI-QKD protocol by encoding the key information into matched discrete phases of two groups of coherent states, which decreases the required detection efficiency for ideally asymmetric cases, and makes it possible to practically achieve secure key distribution with current low-efficiency homodyne detections. Besides, a proof-of-principle experiment with a locally generated oscillator is implemented, which, for the first time, demonstrates the realizability of CV-MDI-QKD using all fiber-based devices. The discrete-modulated phase-matching method provides an alternative direction of an applicable quantum key distribution with practical security.
We propose a novel scheme for measurement-device-independent (MDI) continuous-variable quantum key distribution (CVQKD) by simultaneously conducting classical communication and QKD, which is called “simultaneous MDI-CVQKD” protocol. In such protocol, each sender (Alice, Bob) can superimpose random numbers for QKD on classical information by taking advantage of the same weak coherent pulse and an untrusted third party (Charlie) decodes it by using the same coherent detectors, which could be appealing in practice due to that multiple purposes can be realized by employing only single communication system. What is more, the proposed protocol is MDI, which is immune to all possible side-channel attacks on practical detectors. Security results illustrate that the simultaneous MDI-CVQKD protocol can secure against arbitrary collective attacks. In addition, we employ phase-sensitive optical amplifiers to compensate the imperfection existing in practical detectors. With this technology, even common practical detectors can be used for detection through choosing a suitable optical amplifier gain. Furthermore, we also take the finite-size effect into consideration and show that the whole raw keys can be taken advantage of to generate the final secret key instead of sacrificing part of them for parameter estimation. Therefore, an enhanced performance of the simultaneous MDI-CVQKD protocol can be obtained in finite-size regime.
Continuous variable measurement-device-independent quantum key distribution (CV-MDI-QKD) removes all known or unknown side-channel attacks on detectors. However, it is difficult to fully implement assumptions in the security demonstration model, which leads to potential security vulnerabilities inevitably existing in the practical system. In this paper, we explore the impact of imbalanced modulation at transmitters on the security of the CV-MDI-QKD system mainly using a coherent state and squeezed state under symmetric and asymmetric distances. Assuming two different modulation topologies of senders, we propose a generalized theoretical scheme and evaluate the key parameter achievable of the protocol with the mechanism of imbalanced modulation. The presented results show that imbalanced modulation can achieve a relatively nonlinearly higher secret key rate and transmission distances than the previous protocol which is the balanced modulation variance used by transmitters. The advantage of imbalanced modulation is demonstrated for the system key parameter estimation using numerical simulation under different situations. In addition, the consequences indicate the importance of imbalanced modulation on the performance of CV-MDI-QKD protocol and provide a theoretical framework for experimental implementation as well as the optimal modulated mode.
Continuous-variable measurement-device-independent quantum key distribution (CV-MDI-QKD) is immune to all detector side channel attacks, however its security requires trusted sources. We investigate the effects of source intensity errors, the most crucial source error, on the security of CV-MDI-QKD protocol with Gaussian-modulated coherent states. We establish a general source intensity errors model and derive the secret key rate based on different assumptions on the abilities of legal parties Alice and Bob. To avoid the adverse effects of the sources' intensity errors on CV-MDI-QKD, we present different data-processing schemes. We also assess the security of the protocol against collective Gaussian attacks in the finite-size scenario with composable security. Taking source intensity errors into consideration, we achieve improved security compared to previous demonstrations. Our results will provide a useful reference for practical implementations of CV-MDI-QKD.
We propose a continuous-variable measurement-device-independent quantum key distribution with multi-ring discrete modulation (MR-CV-MDI-QKD) protocol. In our scheme, coherent states are allocated across distinct rings (amplitudes) in the phase space, and each ring is subjected to traditional M-symbol phase shift keying (MPSK) modulation. The analysis and simulation are given to demonstrate the security of our scheme under collective attacks. The results show that, compared with the traditional discrete modulated (DM)-CV-MDI-QKD where only the MPSK is used for modulation with a fixed amplitude, MR-CV-MDI-QKD can decrease the upper bound of the information accessible to an eavesdropper, thereby facilitating an extended transmission distance and increasing the secret key rate, furthermore, it exhibits a higher tolerance to diminished reverse reconciliation efficiency. This work provides an effective way for the practical implementation of the CV-MDI-QKD protocol.
We have introduced, for the first time, a protocol for Continuous-Variable Measurement-Device-Independent Quantum Key Distribution (CV-MDI-QKD) in the terahertz (THz) frequency band. We have conducted a secret key rate analysis against collective attacks. The proposed THz CV-MDI-QKD is immune to all detector attacks, significantly enhancing the security assurance of practical THz CVQKD implementations. Furthermore, we investigated the impact of finite key length (the finite-size effect) and finite reconciliation efficiency on the performance of practical THz CV-MDI-QKD systems. Our findings reveal that by employing a large number of keys or signals and optimizing the modulation variance, the detrimental effects arising from the finite-size effect and suboptimal reconciliation efficiency can be notably mitigated. These insights play a crucial role in advancing the feasibility of THz CVQKD technology towards practical applications.