Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review Letters

Direct Measurement of the Free Cyclotron Frequency of a Single Particle in a Penning Trap

S. Ulmer, K. Blaum, Holger Kracke, Andreas H. Mooser, W. Quint, C. C. Rodegheri, J. Walz

Published Sep 1, 2011• 24 citations
Publisher

Abstract

A measurement scheme for the direct determination of the free cyclotron frequency ν(c) of a single particle stored in a Penning trap is described. The method is based on the dressed states of mode coupling. In this novel measurement scheme both radial modes of the single trapped particle are simultaneously coupled to the axial oscillation mode.

DOI
10.1103/physrevlett.107.103002

Related papers

Quantum non demolition measurement of cyclotron excitations in a Penning trap

Irene Marzoli, Paolo Tombesi

The quantum non-demolition measurement of the cyclotron excitations of an electron confined in a Penning trap could be obtained by measuring the resonance frequency of the axial motion, which is coupled to the cyclotron motion through the relativistic shift of the electron mass.

•Jan 1, 1993•0 citations

Single-Particle Self-Excited Oscillator

Brian D’Urso, Ramon van Handel, Brian Odom +2 more

Electronic feedback is used to self-excite the axial oscillation of a single electron in a Penning trap. Large, stable, easily detected oscillations arise even in an anharmonic potential. Amplitudes are controlled by adjusting the feedback gain, and frequencies can be made nearly independent of amplitude fluctuations. Quantum jump spectroscopy of a perpendicular cyclotron motion reveals the absolute temperature and amplitude of the self-excited oscillation. The possibility to quickly measure parts per billion frequency shifts could open the way to improved measurements of e(-), e(+), p, and (-)p magnetic moments.

Physical Review Letters•Mar 23, 2005•34 citations

Measurements of Motional Frequencies for Laser-cooled Ions in a Penning Trap

Hidetsuka Imajo, Shinji Urabe, Kazuhiro Hayasaka +1 more

The characteristics of laser-cooled Be+ ions stored in a Penning trap are reported. Be+ ions are cooled by a laser to approximately 300 mK and the cyclotron and axial frequencies of the cooled ions are measured by a laser fluorescence technique. In addition, ion resonances are observed when several kinds of ions are trapped with Be+ ions.

Journal of Modern Optics•Feb 1, 1992•16 citations

Measuring the cyclotron state of a trapped electron

Stefano Mancini, Paolo Tombesi

We propose the cyclotron state retrieval of an electron trapped in a Penning trap by using different measurement schemes based on suitable modifications of the applied electromagnetic fields, and exploiting the axial degree of freedom as a probe. A test for the matter-antimatter symmetry of the quantum state is proposed.

arXiv:quant-ph/9707012•Physical Review A•Oct 1, 1997•6 citations

Mode coupling in a Penning trap:πpulses and a classical avoided crossing

Eric Cornell, Robert M. Weisskoff, Kevin Robert Boyce +1 more

An inhomogeneous radiofrequency electric field can couple the cyclotron and axial modes of a single ion in a Penning trap. The classical equations of motion are the same as those of a driven quantum-mechanical two-level system. We discuss an analog of the \ensuremath{\pi} pulse, which can exchange mode actions, and an analog of the avoided crossing. Experimental illustrations are presented.

Physical Review A•Jan 1, 1990•181 citations

Cavity control in a single-electron quantum cyclotron

David Hanneke

A single electron in a quantum cyclotron yields new measurements of the electron magnetic moment, given by g/2 = 1.00115965218073(28)[0.28 ppt], and the fine structure constant, α −1 = 137.035999084(51)[0.37 ppb], both significantly improved from prior results. The static magnetic and electric fields of a Penning trap confine the electron, and a 100 mK dilution refrigerator cools its cyclotron motion to the quantum-mechanical ground state. A quantum nondemolition measurement allows resolution of single cyclotron jumps and spin flips by coupling the cyclotron and spin energies to the frequency of the axial motion, which is self-excited and detected with a cryogenic amplifier. The trap electrodes form a high-Q microwave resonator near the cyclotron frequency; coupling between the cyclotron motion and cavity modes can inhibit spontaneous emission by over 100 timesthe free-space rate and shiftthe cyclotron frequency, a systematic effect that dominated the uncertainties of previous g-value measurements. A cylindrical trap geometry creates cavity modes with analytically calculable couplingsto cyclotron motion. Two independent methods use the cyclotron damping rate of an electron plasma or of the single electron itself as probes of the cavity mode structure and allow the identification ofthe modes by their geometries and couplings, the quantification of an offset between the mode and electrostatic centers, and the reduction of the cavity shift uncertainty to sub-dominant levels. Measuring g at four magnetic fields with cavity shifts spanning thirty times the final g-value uncertainty provides a check on the calculated cavity shifts. Magnetic field fluctuations limit the measurement of g by adding a noise-model dependence to the extraction of the cyclotron and anomaly frequencies from their resonance lines; the relative agreement of two line-splitting methods quantifies a lineshape model uncertainty. New techniques promise to increase field stability, narrow the resonance lines, and accelerate the measurement cycle. The measured g allows tests for physics beyond the Standard Model through searches for its temporal variation and comparisons with a “theoretical” g-value calculated from quantum electrodynamics and an independently measured fine structure constant.

•Jan 1, 2007•0 citations
A measurement scheme for the direct determination of the free cyclotron frequency ν(c) of a single particle stored in a Penning trap is described. The method is based on the dressed states of mode coupling. In this novel measurement scheme both radial modes of the single trapped particle are simultaneously coupled to the axial oscillation mode.
Electronic feedback is used to self-excite the axial oscillation of a single electron in a Penning trap. Large, stable, easily detected oscillations arise even in an anharmonic potential. Amplitudes are controlled by adjusting the feedback gain, and frequencies can be made nearly independent of amplitude fluctuations. Quantum jump spectroscopy of a perpendicular cyclotron motion reveals the absolute temperature and amplitude of the self-excited oscillation. The possibility to quickly measure parts per billion frequency shifts could open the way to improved measurements of e(-), e(+), p, and (-)p magnetic moments.
A single electron in a quantum cyclotron yields new measurements of the electron magnetic moment, given by g/2 = 1.00115965218073(28)[0.28 ppt], and the fine structure constant, α −1 = 137.035999084(51)[0.37 ppb], both significantly improved from prior results. The static magnetic and electric fields of a Penning trap confine the electron, and a 100 mK dilution refrigerator cools its cyclotron motion to the quantum-mechanical ground state. A quantum nondemolition measurement allows resolution of single cyclotron jumps and spin flips by coupling the cyclotron and spin energies to the frequency of the axial motion, which is self-excited and detected with a cryogenic amplifier. The trap electrodes form a high-Q microwave resonator near the cyclotron frequency; coupling between the cyclotron motion and cavity modes can inhibit spontaneous emission by over 100 timesthe free-space rate and shiftthe cyclotron frequency, a systematic effect that dominated the uncertainties of previous g-value measurements. A cylindrical trap geometry creates cavity modes with analytically calculable couplingsto cyclotron motion. Two independent methods use the cyclotron damping rate of an electron plasma or of the single electron itself as probes of the cavity mode structure and allow the identification ofthe modes by their geometries and couplings, the quantification of an offset between the mode and electrostatic centers, and the reduction of the cavity shift uncertainty to sub-dominant levels. Measuring g at four magnetic fields with cavity shifts spanning thirty times the final g-value uncertainty provides a check on the calculated cavity shifts. Magnetic field fluctuations limit the measurement of g by adding a noise-model dependence to the extraction of the cyclotron and anomaly frequencies from their resonance lines; the relative agreement of two line-splitting methods quantifies a lineshape model uncertainty. New techniques promise to increase field stability, narrow the resonance lines, and accelerate the measurement cycle. The measured g allows tests for physics beyond the Standard Model through searches for its temporal variation and comparisons with a “theoretical” g-value calculated from quantum electrodynamics and an independently measured fine structure constant.