Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Quantum non demolition measurement of cyclotron excitations in a Penning trap

Irene Marzoli, Paolo Tombesi

Published Jan 1, 1993• 0 citations
OpenAlex

Abstract

The quantum non-demolition measurement of the cyclotron excitations of an electron confined in a Penning trap could be obtained by measuring the resonance frequency of the axial motion, which is coupled to the cyclotron motion through the relativistic shift of the electron mass.

Related papers

Quantum Non-Demolition Measurement of Cyclotron Excitations and Wave Function Collapse

Irene Marzoli, P. Tombesi

The quantum non-demolition measurement of the cyclotron excitations of an electron trapped in a Penning trap is shown to be accessible, with the modern technology, by only considering the coupling between the axial and the cyclotron motions induced by the relativistic correction to the electron's mass. It is shown that such a measurement is possible only when the spin state of the electron is preassigned and the wave function will then collapse into a Fock state. When this is not the case the wave function of the electron will collapse into an entangled state.

Europhysics Letters (EPL)•Dec 1, 1993•11 citations

Cavity control in a single-electron quantum cyclotron

David Hanneke

A single electron in a quantum cyclotron yields new measurements of the electron magnetic moment, given by g/2 = 1.00115965218073(28)[0.28 ppt], and the fine structure constant, α −1 = 137.035999084(51)[0.37 ppb], both significantly improved from prior results. The static magnetic and electric fields of a Penning trap confine the electron, and a 100 mK dilution refrigerator cools its cyclotron motion to the quantum-mechanical ground state. A quantum nondemolition measurement allows resolution of single cyclotron jumps and spin flips by coupling the cyclotron and spin energies to the frequency of the axial motion, which is self-excited and detected with a cryogenic amplifier. The trap electrodes form a high-Q microwave resonator near the cyclotron frequency; coupling between the cyclotron motion and cavity modes can inhibit spontaneous emission by over 100 timesthe free-space rate and shiftthe cyclotron frequency, a systematic effect that dominated the uncertainties of previous g-value measurements. A cylindrical trap geometry creates cavity modes with analytically calculable couplingsto cyclotron motion. Two independent methods use the cyclotron damping rate of an electron plasma or of the single electron itself as probes of the cavity mode structure and allow the identification ofthe modes by their geometries and couplings, the quantification of an offset between the mode and electrostatic centers, and the reduction of the cavity shift uncertainty to sub-dominant levels. Measuring g at four magnetic fields with cavity shifts spanning thirty times the final g-value uncertainty provides a check on the calculated cavity shifts. Magnetic field fluctuations limit the measurement of g by adding a noise-model dependence to the extraction of the cyclotron and anomaly frequencies from their resonance lines; the relative agreement of two line-splitting methods quantifies a lineshape model uncertainty. New techniques promise to increase field stability, narrow the resonance lines, and accelerate the measurement cycle. The measured g allows tests for physics beyond the Standard Model through searches for its temporal variation and comparisons with a “theoretical” g-value calculated from quantum electrodynamics and an independently measured fine structure constant.

•Jan 1, 2007•0 citations

Single-Particle Self-Excited Oscillator

Brian D’Urso, Ramon van Handel, Brian Odom +2 more

Electronic feedback is used to self-excite the axial oscillation of a single electron in a Penning trap. Large, stable, easily detected oscillations arise even in an anharmonic potential. Amplitudes are controlled by adjusting the feedback gain, and frequencies can be made nearly independent of amplitude fluctuations. Quantum jump spectroscopy of a perpendicular cyclotron motion reveals the absolute temperature and amplitude of the self-excited oscillation. The possibility to quickly measure parts per billion frequency shifts could open the way to improved measurements of e(-), e(+), p, and (-)p magnetic moments.

Physical Review Letters•Mar 23, 2005•34 citations

Cooling and self-excitation of a one-electron oscillator

Brian D’Urso

With a superposition of static electric and magnetic fields, a Penning trap can confine a single electron indefinitely. A weak coupling of the electron to its environment makes the system ideal for precision measurements but renders detection of the electron’s motion difficult. In order to measure fundamental properties of an electron, we employ a Penning trap cooled by a dilution refrigerator. This experimental setup requires extremely low-noise and low-power cryogenic amplifiers for detection of the electron’s axial motion. We design and demonstrate new amplifiers, resulting in a significant decrease of the axial temperature and in an improved signal to noise ratio. We use feedback to cool the axial motion and to self-excite the axial motion for continuous monitoring of the axial frequency. These techniques for cooling and measuring the axial frequency may contribute to an improved measurement of the electron g factor, a more stringent CPT test in leptons, and a more precise measurement of the proton-electron mass ratio.

•Jan 1, 2003•11 citations

QND measurements and wave function collapse in penning traps

Irene Marzoli, Paolo Tombesi

The attained precision of measurements in Penning traps is so high that, for light particles, the relativistic corrections are detectable. Thus, the coupling among the various motions of the trapped particle is provided by the relativistic shift of the mass. A parallel LCR circuit interacting with the elastically bound particle represents the measurement device. The measurement is performed by monitoring the resonance frequency of the spectral function of the output voltage.

Annual Meeting Optical Society of America•Jan 1, 1993•0 citations

Direct Measurement of the Free Cyclotron Frequency of a Single Particle in a Penning Trap

S. Ulmer, K. Blaum, Holger Kracke +4 more

A measurement scheme for the direct determination of the free cyclotron frequency ν(c) of a single particle stored in a Penning trap is described. The method is based on the dressed states of mode coupling. In this novel measurement scheme both radial modes of the single trapped particle are simultaneously coupled to the axial oscillation mode.

Physical Review Letters•Sep 1, 2011•24 citations
The quantum non-demolition measurement of the cyclotron excitations of an electron trapped in a Penning trap is shown to be accessible, with the modern technology, by only considering the coupling between the axial and the cyclotron motions induced by the relativistic correction to the electron's mass. It is shown that such a measurement is possible only when the spin state of the electron is preassigned and the wave function will then collapse into a Fock state. When this is not the case the wave function of the electron will collapse into an entangled state.
A single electron in a quantum cyclotron yields new measurements of the electron magnetic moment, given by g/2 = 1.00115965218073(28)[0.28 ppt], and the fine structure constant, α −1 = 137.035999084(51)[0.37 ppb], both significantly improved from prior results. The static magnetic and electric fields of a Penning trap confine the electron, and a 100 mK dilution refrigerator cools its cyclotron motion to the quantum-mechanical ground state. A quantum nondemolition measurement allows resolution of single cyclotron jumps and spin flips by coupling the cyclotron and spin energies to the frequency of the axial motion, which is self-excited and detected with a cryogenic amplifier. The trap electrodes form a high-Q microwave resonator near the cyclotron frequency; coupling between the cyclotron motion and cavity modes can inhibit spontaneous emission by over 100 timesthe free-space rate and shiftthe cyclotron frequency, a systematic effect that dominated the uncertainties of previous g-value measurements. A cylindrical trap geometry creates cavity modes with analytically calculable couplingsto cyclotron motion. Two independent methods use the cyclotron damping rate of an electron plasma or of the single electron itself as probes of the cavity mode structure and allow the identification ofthe modes by their geometries and couplings, the quantification of an offset between the mode and electrostatic centers, and the reduction of the cavity shift uncertainty to sub-dominant levels. Measuring g at four magnetic fields with cavity shifts spanning thirty times the final g-value uncertainty provides a check on the calculated cavity shifts. Magnetic field fluctuations limit the measurement of g by adding a noise-model dependence to the extraction of the cyclotron and anomaly frequencies from their resonance lines; the relative agreement of two line-splitting methods quantifies a lineshape model uncertainty. New techniques promise to increase field stability, narrow the resonance lines, and accelerate the measurement cycle. The measured g allows tests for physics beyond the Standard Model through searches for its temporal variation and comparisons with a “theoretical” g-value calculated from quantum electrodynamics and an independently measured fine structure constant.
Electronic feedback is used to self-excite the axial oscillation of a single electron in a Penning trap. Large, stable, easily detected oscillations arise even in an anharmonic potential. Amplitudes are controlled by adjusting the feedback gain, and frequencies can be made nearly independent of amplitude fluctuations. Quantum jump spectroscopy of a perpendicular cyclotron motion reveals the absolute temperature and amplitude of the self-excited oscillation. The possibility to quickly measure parts per billion frequency shifts could open the way to improved measurements of e(-), e(+), p, and (-)p magnetic moments.
With a superposition of static electric and magnetic fields, a Penning trap can confine a single electron indefinitely. A weak coupling of the electron to its environment makes the system ideal for precision measurements but renders detection of the electron’s motion difficult. In order to measure fundamental properties of an electron, we employ a Penning trap cooled by a dilution refrigerator. This experimental setup requires extremely low-noise and low-power cryogenic amplifiers for detection of the electron’s axial motion. We design and demonstrate new amplifiers, resulting in a significant decrease of the axial temperature and in an improved signal to noise ratio. We use feedback to cool the axial motion and to self-excite the axial motion for continuous monitoring of the axial frequency. These techniques for cooling and measuring the axial frequency may contribute to an improved measurement of the electron g factor, a more stringent CPT test in leptons, and a more precise measurement of the proton-electron mass ratio.