Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review Letters

Single-Particle Self-Excited Oscillator

Brian D’Urso, Ramon van Handel, Brian Odom, David Hanneke, G. Gabrielse

Published Mar 23, 2005• 34 citations
Publisher

Abstract

Electronic feedback is used to self-excite the axial oscillation of a single electron in a Penning trap. Large, stable, easily detected oscillations arise even in an anharmonic potential. Amplitudes are controlled by adjusting the feedback gain, and frequencies can be made nearly independent of amplitude fluctuations. Quantum jump spectroscopy of a perpendicular cyclotron motion reveals the absolute temperature and amplitude of the self-excited oscillation. The possibility to quickly measure parts per billion frequency shifts could open the way to improved measurements of e(-), e(+), p, and (-)p magnetic moments.

DOI
10.1103/physrevlett.94.113002

Related papers

Cooling and self-excitation of a one-electron oscillator

Brian D’Urso

With a superposition of static electric and magnetic fields, a Penning trap can confine a single electron indefinitely. A weak coupling of the electron to its environment makes the system ideal for precision measurements but renders detection of the electron’s motion difficult. In order to measure fundamental properties of an electron, we employ a Penning trap cooled by a dilution refrigerator. This experimental setup requires extremely low-noise and low-power cryogenic amplifiers for detection of the electron’s axial motion. We design and demonstrate new amplifiers, resulting in a significant decrease of the axial temperature and in an improved signal to noise ratio. We use feedback to cool the axial motion and to self-excite the axial motion for continuous monitoring of the axial frequency. These techniques for cooling and measuring the axial frequency may contribute to an improved measurement of the electron g factor, a more stringent CPT test in leptons, and a more precise measurement of the proton-electron mass ratio.

•Jan 1, 2003•11 citations

Cavity control in a single-electron quantum cyclotron

David Hanneke

A single electron in a quantum cyclotron yields new measurements of the electron magnetic moment, given by g/2 = 1.00115965218073(28)[0.28 ppt], and the fine structure constant, α −1 = 137.035999084(51)[0.37 ppb], both significantly improved from prior results. The static magnetic and electric fields of a Penning trap confine the electron, and a 100 mK dilution refrigerator cools its cyclotron motion to the quantum-mechanical ground state. A quantum nondemolition measurement allows resolution of single cyclotron jumps and spin flips by coupling the cyclotron and spin energies to the frequency of the axial motion, which is self-excited and detected with a cryogenic amplifier. The trap electrodes form a high-Q microwave resonator near the cyclotron frequency; coupling between the cyclotron motion and cavity modes can inhibit spontaneous emission by over 100 timesthe free-space rate and shiftthe cyclotron frequency, a systematic effect that dominated the uncertainties of previous g-value measurements. A cylindrical trap geometry creates cavity modes with analytically calculable couplingsto cyclotron motion. Two independent methods use the cyclotron damping rate of an electron plasma or of the single electron itself as probes of the cavity mode structure and allow the identification ofthe modes by their geometries and couplings, the quantification of an offset between the mode and electrostatic centers, and the reduction of the cavity shift uncertainty to sub-dominant levels. Measuring g at four magnetic fields with cavity shifts spanning thirty times the final g-value uncertainty provides a check on the calculated cavity shifts. Magnetic field fluctuations limit the measurement of g by adding a noise-model dependence to the extraction of the cyclotron and anomaly frequencies from their resonance lines; the relative agreement of two line-splitting methods quantifies a lineshape model uncertainty. New techniques promise to increase field stability, narrow the resonance lines, and accelerate the measurement cycle. The measured g allows tests for physics beyond the Standard Model through searches for its temporal variation and comparisons with a “theoretical” g-value calculated from quantum electrodynamics and an independently measured fine structure constant.

•Jan 1, 2007•0 citations

Quantum jumps between Fock states of an ultracold electron cyclotron oscillator

Steven Peil

Fock states of a oneelectron cyclotron oscillator have been produced and observed nondestructively The states are longlived because spontaneous emission is inhib ited by a factor of using the modied radiation eld of a cylindrical Penning trap Direct nondestructive observation is achieved with a magnetic gradient that is ten times larger than previously possible allowing the states to be resolved with high signaltonoise ratio Quantum jumps up to the n cyclotron level have been observed The potential line broadening from the increased magnetic cou pling is avoided because we have lowered the temperature to which electrons can be cooled by nearly two orders of magnitude to as low as \t mK This is the rst time a trapped elementary particle has been cooled below K At these low temperatures the cyclotron oscillator is completely cooled to its ground state Detection of the electron signal is made possible by a lowpower transistor that was developed in collaboration with condensedmatter colleagues Applications include

•Dec 1, 1999•4 citations

Quantum non demolition measurement of cyclotron excitations in a Penning trap

Irene Marzoli, Paolo Tombesi

The quantum non-demolition measurement of the cyclotron excitations of an electron confined in a Penning trap could be obtained by measuring the resonance frequency of the axial motion, which is coupled to the cyclotron motion through the relativistic shift of the electron mass.

•Jan 1, 1993•0 citations

Single atomic particle at rest in free space

HANS G. DEHMELT

Zero-point level confinement1 in a trap is the quantum-mechanical equivalent of the classical single particle at rest in free space. Such confinement has been demonstrated—by the continuous Stern-Gerlach effect—only for the 150-GHz cyclotron motion in geonium, a single electron permanently confined in a cold Penning trap. Localizing the electron to ≈ 60 μm in the node of a standing wave in the trap cavity approximated free space, but decreased spontaneous emission tenfold. Driving the 60-MHz axial motion on a sideband higher by the ≈ 12-kHz magnetron frequency forced the magnetron motion to absorb the excess photon energy, shrinking its radius to ~ 15μm. Analogous laser cooling has reduced the oscillation amplitude of a Ba+ ion in a Paul rf trap to < 120 nm. As in nuclear magnetic resonance, confinement is now much smaller than the wavelength and sidebands disappear. Quantum jumps to and from an electronic metastable level of Ba+ have been demonstrated. Using In+ or a similar ion, this may make a monoion oscillator optical frequency standard with a 1000-day reproducibility of 10-18 possible.

International Laser Science Conference•Jan 1, 1986•0 citations

1-bit memory using one electron: Parametric oscillations in a Penning trap

Ching-Hsiang Tseng, Daphna G. Enzer, G. Gabrielse +1 more

The parametric oscillation of a single trapped electron is studied and used to measure enhanced spontaneous emission. Hysteresis in this motion provides a 1-bit memory to store information about excitations made with the electron ``in the dark.'' The time dependence and stability criteria for the parametric excitation are examined. The cyclotron motions for one and two electrons are also studied.

Physical Review A•Mar 1, 1999•19 citations
Electronic feedback is used to self-excite the axial oscillation of a single electron in a Penning trap. Large, stable, easily detected oscillations arise even in an anharmonic potential. Amplitudes are controlled by adjusting the feedback gain, and frequencies can be made nearly independent of amplitude fluctuations. Quantum jump spectroscopy of a perpendicular cyclotron motion reveals the absolute temperature and amplitude of the self-excited oscillation. The possibility to quickly measure parts per billion frequency shifts could open the way to improved measurements of e(-), e(+), p, and (-)p magnetic moments.
With a superposition of static electric and magnetic fields, a Penning trap can confine a single electron indefinitely. A weak coupling of the electron to its environment makes the system ideal for precision measurements but renders detection of the electron’s motion difficult. In order to measure fundamental properties of an electron, we employ a Penning trap cooled by a dilution refrigerator. This experimental setup requires extremely low-noise and low-power cryogenic amplifiers for detection of the electron’s axial motion. We design and demonstrate new amplifiers, resulting in a significant decrease of the axial temperature and in an improved signal to noise ratio. We use feedback to cool the axial motion and to self-excite the axial motion for continuous monitoring of the axial frequency. These techniques for cooling and measuring the axial frequency may contribute to an improved measurement of the electron g factor, a more stringent CPT test in leptons, and a more precise measurement of the proton-electron mass ratio.
A single electron in a quantum cyclotron yields new measurements of the electron magnetic moment, given by g/2 = 1.00115965218073(28)[0.28 ppt], and the fine structure constant, α −1 = 137.035999084(51)[0.37 ppb], both significantly improved from prior results. The static magnetic and electric fields of a Penning trap confine the electron, and a 100 mK dilution refrigerator cools its cyclotron motion to the quantum-mechanical ground state. A quantum nondemolition measurement allows resolution of single cyclotron jumps and spin flips by coupling the cyclotron and spin energies to the frequency of the axial motion, which is self-excited and detected with a cryogenic amplifier. The trap electrodes form a high-Q microwave resonator near the cyclotron frequency; coupling between the cyclotron motion and cavity modes can inhibit spontaneous emission by over 100 timesthe free-space rate and shiftthe cyclotron frequency, a systematic effect that dominated the uncertainties of previous g-value measurements. A cylindrical trap geometry creates cavity modes with analytically calculable couplingsto cyclotron motion. Two independent methods use the cyclotron damping rate of an electron plasma or of the single electron itself as probes of the cavity mode structure and allow the identification ofthe modes by their geometries and couplings, the quantification of an offset between the mode and electrostatic centers, and the reduction of the cavity shift uncertainty to sub-dominant levels. Measuring g at four magnetic fields with cavity shifts spanning thirty times the final g-value uncertainty provides a check on the calculated cavity shifts. Magnetic field fluctuations limit the measurement of g by adding a noise-model dependence to the extraction of the cyclotron and anomaly frequencies from their resonance lines; the relative agreement of two line-splitting methods quantifies a lineshape model uncertainty. New techniques promise to increase field stability, narrow the resonance lines, and accelerate the measurement cycle. The measured g allows tests for physics beyond the Standard Model through searches for its temporal variation and comparisons with a “theoretical” g-value calculated from quantum electrodynamics and an independently measured fine structure constant.
Fock states of a oneelectron cyclotron oscillator have been produced and observed nondestructively The states are longlived because spontaneous emission is inhib ited by a factor of using the modied radiation eld of a cylindrical Penning trap Direct nondestructive observation is achieved with a magnetic gradient that is ten times larger than previously possible allowing the states to be resolved with high signaltonoise ratio Quantum jumps up to the n cyclotron level have been observed The potential line broadening from the increased magnetic cou pling is avoided because we have lowered the temperature to which electrons can be cooled by nearly two orders of magnitude to as low as \t mK This is the rst time a trapped elementary particle has been cooled below K At these low temperatures the cyclotron oscillator is completely cooled to its ground state Detection of the electron signal is made possible by a lowpower transistor that was developed in collaboration with condensedmatter colleagues Applications include
Zero-point level confinement1 in a trap is the quantum-mechanical equivalent of the classical single particle at rest in free space. Such confinement has been demonstrated—by the continuous Stern-Gerlach effect—only for the 150-GHz cyclotron motion in geonium, a single electron permanently confined in a cold Penning trap. Localizing the electron to ≈ 60 μm in the node of a standing wave in the trap cavity approximated free space, but decreased spontaneous emission tenfold. Driving the 60-MHz axial motion on a sideband higher by the ≈ 12-kHz magnetron frequency forced the magnetron motion to absorb the excess photon energy, shrinking its radius to ~ 15μm. Analogous laser cooling has reduced the oscillation amplitude of a Ba+ ion in a Paul rf trap to < 120 nm. As in nuclear magnetic resonance, confinement is now much smaller than the wavelength and sidebands disappear. Quantum jumps to and from an electronic metastable level of Ba+ have been demonstrated. Using In+ or a similar ion, this may make a monoion oscillator optical frequency standard with a 1000-day reproducibility of 10-18 possible.