Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Low Temperature Physics

Energy Collection Efficiency of Tungsten Transition-Edge Sensors in the Near-Infrared

Adriana E. Lita, Aaron Miller, Sae Woo Nam

Published Jan 8, 2008• 19 citations
Publisher
DOI
10.1007/s10909-007-9627-z

Related papers

Improving Energy Detection Efficiency of Ti-Based Superconducting Transition-Edge Sensors with Optical Cavity

Y. Geng, Wen Zhang, Peng Li +7 more

Journal of Low Temperature Physics•Feb 13, 2020•13 citations

High count-rate superconducting transition edge sensors for near-IR single photon detection

Faustin Carter, Daniel F. Santavicca, Luigi Frunzio +2 more

Bulletin of the American Physical Society•Mar 23, 2011•0 citations

Performance of photon-number resolving transition-edge sensors with integrated 1550 nm resonant cavities

Danna Rosenberg, Adriana E. Lita, Aaron Miller +2 more

Many quantum-information applications require high-efficiency, low-noise, single-photon detectors that operate at visible and near-infrared wavelengths. The tunable superconducting critical temperature and anomalously low electron-phonon coupling of tungsten make it a suitable material for the fabrication of transition-edge sensors (TESs) that meet these requirements. The quantum efficiency of a typical tungsten TES detector, intrinsically around 15% at 1550 nm, can be increased by placing the tungsten detector in a resonant cavity, but the performance of a device embedded in a cavity has not been tested previously. We demonstrate that the presence of the cavity does not adversely affect the sensitivity or response time, and we report on the device characteristics of a new generation of tungsten TESs with greater than 80% quantum efficiency at 1550 nm.

IEEE Transactions on Applied Superconductivity•Jun 1, 2005•62 citations

High quantum efficiency, Ir-transition edge sensor

Mikihisa Matsuyama, Mamoru Endo, Casper R. Breum +5 more

The Japan Society of Applied Physics•Jul 10, 2019•0 citations

Faster recovery time of a hot-electron transition-edge sensor by use of normal metal heat-sinks

Brice Calkins, Adriana E. Lita, Anna E. Fox +1 more

Transition-edge sensor microcalorimeters with recovery times near 1 μs have become highly desirable in quantum science applications as near-infrared single-photon detectors with photon-number resolving capability. Previously, the recovery times of these devices could be decreased only by changing device material or modifying the superconducting-to-normal transition. We demonstrate a method for improving this speed that uses a normal-metal heat-sink. This demonstration with tungsten devices realizes a factor of 4 decrease in recovery time without significantly affecting energy resolution. Our approach may enable the creation of high-efficiency transition-edge sensors with decay times short enough to operate with 80 MHz pulsed single-photon sources.

Applied Physics Letters•Dec 12, 2011•32 citations

Implications of Weak Link Effects on Thermal Characteristics of Transition-Edge Sensors

Catherine N. Bailey, J. S. Adams, S. R. Bandler +10 more

Journal of Low Temperature Physics•Feb 9, 2012•10 citations
Many quantum-information applications require high-efficiency, low-noise, single-photon detectors that operate at visible and near-infrared wavelengths. The tunable superconducting critical temperature and anomalously low electron-phonon coupling of tungsten make it a suitable material for the fabrication of transition-edge sensors (TESs) that meet these requirements. The quantum efficiency of a typical tungsten TES detector, intrinsically around 15% at 1550 nm, can be increased by placing the tungsten detector in a resonant cavity, but the performance of a device embedded in a cavity has not been tested previously. We demonstrate that the presence of the cavity does not adversely affect the sensitivity or response time, and we report on the device characteristics of a new generation of tungsten TESs with greater than 80% quantum efficiency at 1550 nm.
Transition-edge sensor microcalorimeters with recovery times near 1 μs have become highly desirable in quantum science applications as near-infrared single-photon detectors with photon-number resolving capability. Previously, the recovery times of these devices could be decreased only by changing device material or modifying the superconducting-to-normal transition. We demonstrate a method for improving this speed that uses a normal-metal heat-sink. This demonstration with tungsten devices realizes a factor of 4 decrease in recovery time without significantly affecting energy resolution. Our approach may enable the creation of high-efficiency transition-edge sensors with decay times short enough to operate with 80 MHz pulsed single-photon sources.