Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Pramana

High sensitivity probe absorption technique for time-of-flight measurements on cold atoms

Ashok Kumar Mohapatra, C. S. Unnikrishnan

Published Jun 1, 2006• 3 citations
Publisher
DOI
10.1007/bf02708456

Related papers

Temperature measurement of cold atoms in a cesium magneto-optical trap by means of short-distance time-of-flight absorption spectrum

Tao Geng, 闫树斌 Yan Shubin, Yanhua Wang +4 more

We report the basic idea and experimental demonstration of measuring the temperature of cold cesium atomic cloud confined in a magneto-optical trap (MOT) by analyzing absorption spectrum observed in the short-distance time-of-flight (TOF) method. Compared with the conventional TOF scheme, we measure the temperature of cold atomic cloud in MOT by short-distance TOF method for our small vapor cell. If the cold atomic cloud is released, it will fall and expand due to gravity and its initial velocity distribution. Utilizing a cylindrical resonant probe beam positioned several millimeters beneath the MOT (in this paper, we analyzed the cases for 3mm, 5mm, and 8mm of center-to-center distance between the MOT region and the probe beam, respectively), we can record the short-distance TOF absorption spectrum with a photodiode when cold atoms go through the probe region. Analysis of the short-distance TOF absorption spectrum yields the effective temperature of the cold cloud in MOT.

Acta Physica Sinica•Jan 1, 2005•7 citations

Preparation of cold atoms for precision measurements

R. Cloppenburg, G. Hennig, J. Nellessen +1 more

Springer eBooks•Apr 7, 2008•0 citations

The Error Analyzing and Comparing between Theoretical and Approximate Simulated Formula in Measuring The Temperature of Cold Atoms with Short-distance Time-of-flight Method

Hai Wang

The error analyzing and comparing between theoretical and approximate simulated formula in measuring the temperature of cold atoms with short-distance time-of-flight(TOF) method are reported.The results shows that the approximate simulated formula aqrees well with the theoretical simulated formula when the ratio of the radius of probe to the cold atoms is less than 0.2.When the ratio of the radius of probe to the cold atoms approachs 0.5,the error between the approximate simulated formula with the theoretical simulated formula for TOF absorption signal is significant.

Acta Sinica Quantum Optica•Jan 1, 2006•0 citations

Spectroscopy of Cold, Trapped Atoms

Tomasz Brzozowski, Maria Brzozowska, Jerzy Zachorowski +1 more

Acta Physica Hungarica A) Heavy Ion Physics•Nov 1, 2006•3 citations

A High Sensitivity Modulation Method for Atomic Beam Absorption Spectroscopy

Ch Salomon, H. Metcalf, Alain Aspect +1 more

Springer series in optical sciences/SPringer series in optical sciences•Jan 1, 1987•0 citations

Influence of parameter errors on the temperature measurement of cold atoms via short-distance time-of-flight absorption spectra

He Jun, Wang Jing, Qiu Ying +4 more

The basic model and the experimental measurement method of short-distance time-of-flight absorption spectra for determining the temperature of cold atoms are described. Based on the realization of temperature measurement of cold cesium atoms in a magneto-optical trap,the influences of measurement errors of the three experimental parameters,namely the falling distance h,the initial Gaussian radius σ0 of the cold cloud, and the Gaussian radius σp of probe beam, on the determination of temperature have been analyzed and compared.

Acta Physica Sinica•Jan 1, 2008•0 citations
We report the basic idea and experimental demonstration of measuring the temperature of cold cesium atomic cloud confined in a magneto-optical trap (MOT) by analyzing absorption spectrum observed in the short-distance time-of-flight (TOF) method. Compared with the conventional TOF scheme, we measure the temperature of cold atomic cloud in MOT by short-distance TOF method for our small vapor cell. If the cold atomic cloud is released, it will fall and expand due to gravity and its initial velocity distribution. Utilizing a cylindrical resonant probe beam positioned several millimeters beneath the MOT (in this paper, we analyzed the cases for 3mm, 5mm, and 8mm of center-to-center distance between the MOT region and the probe beam, respectively), we can record the short-distance TOF absorption spectrum with a photodiode when cold atoms go through the probe region. Analysis of the short-distance TOF absorption spectrum yields the effective temperature of the cold cloud in MOT.
The error analyzing and comparing between theoretical and approximate simulated formula in measuring the temperature of cold atoms with short-distance time-of-flight(TOF) method are reported.The results shows that the approximate simulated formula aqrees well with the theoretical simulated formula when the ratio of the radius of probe to the cold atoms is less than 0.2.When the ratio of the radius of probe to the cold atoms approachs 0.5,the error between the approximate simulated formula with the theoretical simulated formula for TOF absorption signal is significant.
The basic model and the experimental measurement method of short-distance time-of-flight absorption spectra for determining the temperature of cold atoms are described. Based on the realization of temperature measurement of cold cesium atoms in a magneto-optical trap,the influences of measurement errors of the three experimental parameters,namely the falling distance h,the initial Gaussian radius σ0 of the cold cloud, and the Gaussian radius σp of probe beam, on the determination of temperature have been analyzed and compared.