Journal of Modern Optics

Ion Oscillation Frequencies in a Combined Trap

David John Bate, Kishan Dholakia, Richard Claude Thompson, D. C. Wilson

Published Feb 1, 1992• 55 citations
Publisher

Abstract

A combined trap is a quadrupole trap to which the fields of both the Paul and the Penning traps are applied. In this paper, equations of motion for ions confined in a combined trap are derived from first principles. The equations of motion are shown to give well-understood solutions for the Paul and Penning traps in the appropriate cases before they are solved to yield the axial and radial oscillation frequencies for ions in a combined trap. The dependence of these oscillation frequencies on the applied fields is investigated.

DOI
10.1080/09500349214550301

Related papers

Ion dynamics in perturbed quadrupole ion traps

G. Horváth, José Luis Hernández‐Pozos, Kishan Dholakia +3 more

We use the results of a Lagrangian formulation of the dynamics of ions in a Penning trap to calculate the motional frequencies of the ions as a function of the trapping parameters. We then add realistic perturbations to the ideal trapping fields in the formalism and deduce the effects of these perturbations on the ion motion. For an ideal trap there exist values of the applied trapping fields that result in a degeneracy in the ion oscillation frequencies associated with different types of motion. We show that this motional frequency degeneracy is lifted by the inclusion of the effect of a tilt of the trap axis with respect to the axis of the applied magnetic field, leading to an ``avoided crossing'' between the oscillation frequencies. We calculate typical ion orbits for trap parameters that give oscillation frequencies near the avoided crossing between the axial and modified cyclotron frequencies. We generalize the analysis to include the motion of ions in a combined (Penning-Paul) trap and perform an experiment to test the predictions of the theory for a degeneracy between the modified cyclotron frequency and the axial frequency for ${\mathrm{Mg}}^{+}$ ions held in a tilted combined trap. The oscillation frequencies are measured for a range of tilt angles using a photon-photon correlation technique. There is good agreement between the experimental results and the theoretical predictions. The method we describe may prove to be a useful means by which trap imperfections can be identified and subsequently removed.

Physical Review A•Mar 1, 1998•28 citations

Photon-correlation detection of ion-oscillation frequencies in quadrupole ion traps

Kishan Dholakia, G. Horváth, D. M. Segal +3 more

We present a method for measuring ion-oscillation frequencies in quadrupole traps (Paul, Penning, and combined traps). The method depends on a statistical analysis of the delays between detected fluorescence photons. We have used the method to verify the oscillation frequencies for magnesium ions in a Penning trap as a function of the dc voltage applied to the trap electrodes. We demonstrate that, as expected, the method measures the space-charge shifted (individual-ion) oscillation frequency and not the frequency at which the ion cloud as a whole moves. However, our data suggest that for most of our operating conditions, the space-charge shift is negligible. We also discuss the effect of the contact potential arising from areas of the trap electrodes that are coated by excess Mg from the atomic beam used. We show that this extra potential shifts the center of the Penning trap and makes it unstable for low values of the applied voltage.

Physical Review A•Jan 1, 1993•30 citations

Ion dynamics and oscillation frequencies in a linear combined trap

T. Nakamura, S. Ohtani, M. Wada +3 more

Ion traps have been pivotal in opening new frontiers for the precision spectroscopy of stable ions. We report on the demonstration of an additional ion trap: the linear combined trap. This device is particularly well suited for trapping ions with unstable nuclei, due to its large range of stability parameters that facilitates external injection online to an accelerator. The motion of an ion in such a linear combined trap is investigated theoretically and experimentally. In the trap ions oscillate harmonically in the radial direction and move nearly harmonically between fixed boundaries along the longitudinal axis. The presence of a homogeneous magnetic field and the applied dc and rf electric fields, lead to a set of coupled Mathieu equations. Their approximate solutions exhibit motional frequencies, which are combinations of shifted macromotion frequencies and the cyclotron frequency. The dependence of these motional frequencies on the applied trapping fields was studied in detail. For the measurements we used small clouds of laser cooled B9e+ ions and crystallized B9e+ ions. The observed oscillation frequencies are compared to both the results of zeroth order analytical solutions and to numerical simulations in which the frequency spectrum was obtained from the ion orbits by using the fast fourier transform formalism. The various motional resonances were experimentally recorded by applying a weak dipole excitation field to one of the trap electrodes, and by simultaneously observing at resonance the changes in the fluorescence intensity. Depending on the detuning of the cooling laser the ions gain energy during the motional excitation process in such a way that they are shifted further in or out of optical resonance by the Doppler effect. This leads to either positive or negative ion motion signals at the various ion oscillation frequencies.

Journal of Applied Physics•Mar 1, 2001•11 citations

The dynamics of laser cooled ions in a quadrupole ion trap

Kishan Dholakia

This thesis describes experimental work performed on laser cooled magnesium ions, confined in a quadrupole ion trap operating in the Penning or the combined mode. Information is gained about the dynamical motion of the ions. This is done by analyzing the time delays between scattered fluorescence photons in the case of small ion clouds (generally less than ten ions). For larger clouds (upwards of 100 ions), a fraction of the ions is "tagged" and a subsequent study made of the time evolution of the fluorescence. We have developed an innovative, non-invasive method for measuring ion oscillation frequencies which is based on analyzing photon-photon correlations present in the emitted ion fluorescence. This technique has been used to measure all three Penning trap frequencies for a wide range of dc voltage. The data have been fitted to theory and we have obtained a global fit of these data to one set of trap parameters. We also demonstrate that our technique enables us to measure space-charge shifted values of the trap resonances. This method has also been applied to the combined trap and we report experimental verification of the predicted trap resonances for a wide range of trapping parameters. These data fit well to theory. This is for all three oscillation frequencies for one set of trap parameters consistent with the data for the Penning trap. \nFurther experiments are reported concerned with the dynamics of larger ion clouds in a Penning trap. A pulsed laser is used to "tag" a small number of the ions in large ion clouds. This removes those ions from the cooling cycle by placing them in a metastable state. Subsequently, we have monitored the time evolution of the fluorescence. By analyzing these data we have been able to determine cloud rotation frequencies for large ensembles of ions.

•Jan 1, 1994•0 citations

Nonlinear Integrable Ion Traps

Sergei Nagaitsev, V. Danilov

Quadrupole ion traps can be transformed into nonlinear traps with integrable motion by adding special electrostatic potentials. This can be done with both stationary potentials (electrostatic plus a uniform magnetic field) and with time-dependent electric potentials. These potentials are chosen such that the single particle Hamilton-Jacobi equations of motion are separable in some coordinate systems. The electrostatic potentials have several free adjustable parameters allowing for a quadrupole trap to be transformed into, for example, a double-well or a toroidal-well system. The particle motion remains regular, non-chaotic, integrable in quadratures, and stable for a wide range of parameters. We present two examples of how to realize such a system in case of a time-independent (the Penning trap) as well as a time-dependent (the Paul trap) configuration.

arXiv:1111.1260•Nov 4, 2011•2 citations

Harmonic linear Paul trap: Stability diagram and effective potentials

Michael Drewsen, A. Brøner

We present the single-particle stability diagram for the radial motion in a linear Paul trap in a situation where the applied axial dc potential gives rise to a harmonic defocusing radial potential. Although most linear Paul trap experiments have been conducted in a regime where this approximation is reasonably valid, the effect of the axial confinement on the stability of the radial motion has not previously been analyzed. The defocusing effect in both radial directions leads to a stability diagram different from that of the two-dimensional quadrupole mass filter, and hence points toward new studies of few ion dynamics. Expressions for the effective or pseudopotentials for one and two charged particles are presented and discussed.

Physical Review A•Sep 11, 2000•87 citations
A combined trap is a quadrupole trap to which the fields of both the Paul and the Penning traps are applied. In this paper, equations of motion for ions confined in a combined trap are derived from first principles. The equations of motion are shown to give well-understood solutions for the Paul and Penning traps in the appropriate cases before they are solved to yield the axial and radial oscillation frequencies for ions in a combined trap. The dependence of these oscillation frequencies on the applied fields is investigated.
We use the results of a Lagrangian formulation of the dynamics of ions in a Penning trap to calculate the motional frequencies of the ions as a function of the trapping parameters. We then add realistic perturbations to the ideal trapping fields in the formalism and deduce the effects of these perturbations on the ion motion. For an ideal trap there exist values of the applied trapping fields that result in a degeneracy in the ion oscillation frequencies associated with different types of motion. We show that this motional frequency degeneracy is lifted by the inclusion of the effect of a tilt of the trap axis with respect to the axis of the applied magnetic field, leading to an ``avoided crossing'' between the oscillation frequencies. We calculate typical ion orbits for trap parameters that give oscillation frequencies near the avoided crossing between the axial and modified cyclotron frequencies. We generalize the analysis to include the motion of ions in a combined (Penning-Paul) trap and perform an experiment to test the predictions of the theory for a degeneracy between the modified cyclotron frequency and the axial frequency for Mg+{\mathrm{Mg}}^{+}Mg+ ions held in a tilted combined trap. The oscillation frequencies are measured for a range of tilt angles using a photon-photon correlation technique. There is good agreement between the experimental results and the theoretical predictions. The method we describe may prove to be a useful means by which trap imperfections can be identified and subsequently removed.
We present a method for measuring ion-oscillation frequencies in quadrupole traps (Paul, Penning, and combined traps). The method depends on a statistical analysis of the delays between detected fluorescence photons. We have used the method to verify the oscillation frequencies for magnesium ions in a Penning trap as a function of the dc voltage applied to the trap electrodes. We demonstrate that, as expected, the method measures the space-charge shifted (individual-ion) oscillation frequency and not the frequency at which the ion cloud as a whole moves. However, our data suggest that for most of our operating conditions, the space-charge shift is negligible. We also discuss the effect of the contact potential arising from areas of the trap electrodes that are coated by excess Mg from the atomic beam used. We show that this extra potential shifts the center of the Penning trap and makes it unstable for low values of the applied voltage.
Ion traps have been pivotal in opening new frontiers for the precision spectroscopy of stable ions. We report on the demonstration of an additional ion trap: the linear combined trap. This device is particularly well suited for trapping ions with unstable nuclei, due to its large range of stability parameters that facilitates external injection online to an accelerator. The motion of an ion in such a linear combined trap is investigated theoretically and experimentally. In the trap ions oscillate harmonically in the radial direction and move nearly harmonically between fixed boundaries along the longitudinal axis. The presence of a homogeneous magnetic field and the applied dc and rf electric fields, lead to a set of coupled Mathieu equations. Their approximate solutions exhibit motional frequencies, which are combinations of shifted macromotion frequencies and the cyclotron frequency. The dependence of these motional frequencies on the applied trapping fields was studied in detail. For the measurements we used small clouds of laser cooled B9e+ ions and crystallized B9e+ ions. The observed oscillation frequencies are compared to both the results of zeroth order analytical solutions and to numerical simulations in which the frequency spectrum was obtained from the ion orbits by using the fast fourier transform formalism. The various motional resonances were experimentally recorded by applying a weak dipole excitation field to one of the trap electrodes, and by simultaneously observing at resonance the changes in the fluorescence intensity. Depending on the detuning of the cooling laser the ions gain energy during the motional excitation process in such a way that they are shifted further in or out of optical resonance by the Doppler effect. This leads to either positive or negative ion motion signals at the various ion oscillation frequencies.
This thesis describes experimental work performed on laser cooled magnesium ions, confined in a quadrupole ion trap operating in the Penning or the combined mode. Information is gained about the dynamical motion of the ions. This is done by analyzing the time delays between scattered fluorescence photons in the case of small ion clouds (generally less than ten ions). For larger clouds (upwards of 100 ions), a fraction of the ions is "tagged" and a subsequent study made of the time evolution of the fluorescence. We have developed an innovative, non-invasive method for measuring ion oscillation frequencies which is based on analyzing photon-photon correlations present in the emitted ion fluorescence. This technique has been used to measure all three Penning trap frequencies for a wide range of dc voltage. The data have been fitted to theory and we have obtained a global fit of these data to one set of trap parameters. We also demonstrate that our technique enables us to measure space-charge shifted values of the trap resonances. This method has also been applied to the combined trap and we report experimental verification of the predicted trap resonances for a wide range of trapping parameters. These data fit well to theory. This is for all three oscillation frequencies for one set of trap parameters consistent with the data for the Penning trap. \nFurther experiments are reported concerned with the dynamics of larger ion clouds in a Penning trap. A pulsed laser is used to "tag" a small number of the ions in large ion clouds. This removes those ions from the cooling cycle by placing them in a metastable state. Subsequently, we have monitored the time evolution of the fluorescence. By analyzing these data we have been able to determine cloud rotation frequencies for large ensembles of ions.
Quadrupole ion traps can be transformed into nonlinear traps with integrable motion by adding special electrostatic potentials. This can be done with both stationary potentials (electrostatic plus a uniform magnetic field) and with time-dependent electric potentials. These potentials are chosen such that the single particle Hamilton-Jacobi equations of motion are separable in some coordinate systems. The electrostatic potentials have several free adjustable parameters allowing for a quadrupole trap to be transformed into, for example, a double-well or a toroidal-well system. The particle motion remains regular, non-chaotic, integrable in quadratures, and stable for a wide range of parameters. We present two examples of how to realize such a system in case of a time-independent (the Penning trap) as well as a time-dependent (the Paul trap) configuration.
We present the single-particle stability diagram for the radial motion in a linear Paul trap in a situation where the applied axial dc potential gives rise to a harmonic defocusing radial potential. Although most linear Paul trap experiments have been conducted in a regime where this approximation is reasonably valid, the effect of the axial confinement on the stability of the radial motion has not previously been analyzed. The defocusing effect in both radial directions leads to a stability diagram different from that of the two-dimensional quadrupole mass filter, and hence points toward new studies of few ion dynamics. Expressions for the effective or pseudopotentials for one and two charged particles are presented and discussed.