IRE Transactions on Electron Devices

Recovery techniques for saturated massers

Günter Wessel

Published Apr 1, 1960• 0 citations
Publisher

Abstract

The practical applicability of Masers is often hindered by saturation effects of the maser material. Any strong signal of the same frequency as the maser signal frequency will cause saturation, thus paralyzing the maser for a period of time which is often too long for the intended application. These difficulties have been overcome by desaturating a four-level ruby maser immediately after the maser has been saturated. The experiment was carried out at a signal frequency of 2.5 KMc using an X-band pump. Full recovery of the amplification capabilities of the maser was achieved.

DOI
10.1109/t-ed.1960.14659

Related papers

Recovery technique for saturated masers

Günter Wessel

The practical application of masers is often hindered by saturation effects of the maser material. Any strong signal frequency (e.g., the transmitter pulse of a radar system leaking into the maser) will cause saturation. This paralyzes the maser for a period of time, too long for most intended applications. In this report, a method is described which has been used in desaturating a four-level ruby maser. The saturation is caused by equalizing the populations of levels one, two, and three of the maser crystal by the leakage of the transmitter pulse, in addition to the action of the maser pump. The application of a desaturation pulse between levels one and four will then desaturate the maser restoring the excess population density between levels two and one. In a cavity maser, full recovery of the amplification capabilities has been achieved within less than 1 msec after the maser has been saturated. Repetition rates up to 120 cps are tolerable.

IRE Transactions on Electron Devices•Oct 1, 1960•2 citations

Maser Operation at Signal Frequencies Higher than Pump Frequency

Frank R. Arams

Methods using harmonic spin coupling for operating solid-state masers with signal frequencies higher than the pump frequency are discussed. Expressions for the population inversion ratios are presented, and the maximum signal-to-pump-frequency ratios are calculated. Experimental data is presented on a ruby maser which is operated using the symmetrical method. Amplification was obtained at signal frequencies from 10,320 to 10,740 Mc, using pump frequencies ranging from 9580 to 9670 Mc. An experiment in which maser operation is obtained simultaneously at two frequencies is described.

IEEE Transactions on Microwave Theory and Techniques•Jan 1, 1961•10 citations

Seesaw Maser Operation

Paul Forrester, W. B. Mims

Cross relaxation between adjacent intervals may be used to secure an advantage in maser operation comparable to that obtained by ``push-pull'' pumping. Equations for the rate of change of populations in a scheme of four levels (A,B,C,D) when AC is pumped and cross relaxation takes place between BC, CD have been formulated, and the steady-state condition corresponding to various assumptions regarding lattice relaxation times is discussed. In an experimental investigation of maser operation based on this scheme and using ruby as the active material, an inversion of 0.9:1 was obtained at a signal frequency of 14.5 kMc when pumping at 24.5 kMc.

Journal of Applied Physics•Feb 1, 1961•3 citations

Cavity Maser Experiments using Ruby at S Band†

W.S.C. Chang, J.C. Cromack, Anthony E.. Siegman

A three-level solid-state maser using ruby has been operated at frequencies near 3000 Mc/s, using a high-efficiency cavity having TEM modes in a rectangular geometry. Two different operating points in the θ = 10° to θ =30 ° region of the ruby spectrum gave maser operation with a pump frequency near 10 500 Mc/s, although the inversion obtained was a. sensitive function of the exact operating point. An operating point at θ = 90°, requiring pumping at 13 500 Mc/s, gave a gain-bandwidth product of better than 50 Mc/s. It was also found possible to pump the 1-4 or ΔM = 3 transition at this same operating point, obtaining 3000 Mc/s amplification with a 23 700 Mc/s pump frequency. Although this mode of operation was not fully explored, it is potentially capable of increasing the gain-bandwidth product by a substantial amount.

Journal of Electronics and Control•Jun 1, 1959•4 citations

Ruby as a Maser Material

Chihiro Kikuchi, John Lambe, George Makhov +1 more

The reasons for the initial choice of ruby as a maser material are outlined and some measurements of the parameters in the spin Hamiltonian and of spin relaxation times are reported. The relative merits of single- and double-pump modes of operation of a four-level maser are discussed and measurements of the oscillator power for the two cases are included.

Journal of Applied Physics•Jul 1, 1959•64 citations

Two-frequency ruby maser

Zh A Arakelyan, I G Karayan, R. М. Мartirosyan +1 more

A description is given of a two-frequency ruby maser capable of amplification at frequencies of 1.3 and 9.4 GHz. The values of the inversion coefficients and gains at these frequencies are given. It is shown that the same configuration can be used to widen the maser band when the energy intervals 1?2 and 3?4 between the levels differ by the ESR line width. Possible applications of such amplifiers are indicated.

Soviet Journal of Quantum Electronics•Dec 31, 1975•1 citation
The practical applicability of Masers is often hindered by saturation effects of the maser material. Any strong signal of the same frequency as the maser signal frequency will cause saturation, thus paralyzing the maser for a period of time which is often too long for the intended application. These difficulties have been overcome by desaturating a four-level ruby maser immediately after the maser has been saturated. The experiment was carried out at a signal frequency of 2.5 KMc using an X-band pump. Full recovery of the amplification capabilities of the maser was achieved.
The practical application of masers is often hindered by saturation effects of the maser material. Any strong signal frequency (e.g., the transmitter pulse of a radar system leaking into the maser) will cause saturation. This paralyzes the maser for a period of time, too long for most intended applications. In this report, a method is described which has been used in desaturating a four-level ruby maser. The saturation is caused by equalizing the populations of levels one, two, and three of the maser crystal by the leakage of the transmitter pulse, in addition to the action of the maser pump. The application of a desaturation pulse between levels one and four will then desaturate the maser restoring the excess population density between levels two and one. In a cavity maser, full recovery of the amplification capabilities has been achieved within less than 1 msec after the maser has been saturated. Repetition rates up to 120 cps are tolerable.
Methods using harmonic spin coupling for operating solid-state masers with signal frequencies higher than the pump frequency are discussed. Expressions for the population inversion ratios are presented, and the maximum signal-to-pump-frequency ratios are calculated. Experimental data is presented on a ruby maser which is operated using the symmetrical method. Amplification was obtained at signal frequencies from 10,320 to 10,740 Mc, using pump frequencies ranging from 9580 to 9670 Mc. An experiment in which maser operation is obtained simultaneously at two frequencies is described.
Cross relaxation between adjacent intervals may be used to secure an advantage in maser operation comparable to that obtained by ``push-pull'' pumping. Equations for the rate of change of populations in a scheme of four levels (A,B,C,D) when AC is pumped and cross relaxation takes place between BC, CD have been formulated, and the steady-state condition corresponding to various assumptions regarding lattice relaxation times is discussed. In an experimental investigation of maser operation based on this scheme and using ruby as the active material, an inversion of 0.9:1 was obtained at a signal frequency of 14.5 kMc when pumping at 24.5 kMc.
A three-level solid-state maser using ruby has been operated at frequencies near 3000 Mc/s, using a high-efficiency cavity having TEM modes in a rectangular geometry. Two different operating points in the θ = 10° to θ =30 ° region of the ruby spectrum gave maser operation with a pump frequency near 10 500 Mc/s, although the inversion obtained was a. sensitive function of the exact operating point. An operating point at θ = 90°, requiring pumping at 13 500 Mc/s, gave a gain-bandwidth product of better than 50 Mc/s. It was also found possible to pump the 1-4 or ΔM = 3 transition at this same operating point, obtaining 3000 Mc/s amplification with a 23 700 Mc/s pump frequency. Although this mode of operation was not fully explored, it is potentially capable of increasing the gain-bandwidth product by a substantial amount.