Journal of Applied Physics

Noise Analysis for Amplifiers with Superconducting Input

V. Radhakrishnan, Vernon Leopold Newhouse

Published Jan 1, 1971• 17 citations
Publisher

Abstract

A method is developed to adapt the conventional definition of the noise temperature to amplifiers with superconducting inputs. In particular this method is applied to a crossed-film cryotron amplifier with a superconducting input to calculate its noise temperature. We then compare it with that of other amplifiers and masers. In addition to the noise temperature, a new criterion is evolved here: to estimate the figure of merit of amplifiers and detectors. This involves a new parameter called herein the action factor, which is the product of the smallest energy measurable by a device, with its smallest possible response time. The action factor and the noise temperature are worked out for the cryotron and a few other amplifiers and detectors for comparison. The advantage of the cryotron amplifier is brought out.

DOI
10.1063/1.1659544

Related papers

Direct spectrum analysis using a threshold detector with application to a superconducting circuit

Grégoire Ithier, Giovanna Tancredi, P. J. Meeson

We introduce a new and quantitative theoretical framework for noise spectral analysis using a threshold detector, which is then applied to a superconducting device: the Josephson bifurcation amplifier. We show that this new framework provides direct access to the environmental noise spectrum with a sensitivity approaching the standard quantum limit of weak continuous measurements. In addition, the accessible frequency range of the spectrum is, in principle, limited only by the ring down time of the resonant mode. This on-chip noise detector is non-dissipative and works with low probing powers, allowing it to be operated at low temperatures ( mK). We exploit this technique for measuring the frequency fluctuations of our device and find a low frequency noise with an amplitude and spectrum compatible with a dielectric origin.

arXiv:1312.3298•New Journal of Physics•May 14, 2014•5 citations

Design and Analysis on a Cryogenic Current Amplifier with a Superconducting Microwave Resonator

Yuma Okazaki, Nobu‐Hisa Kaneko

We propose a new type of cryogenic current amplifiers, in which low-frequency power spectrum of current can be measured through a measurement of microwave response of a superconducting resonant circuit shunted by a series array of Josephson junctions. From numerical analysis on the equivalent circuit, the numerical value of the input-referred current noise of the proposed amplifier is found to be two orders of magnitude lower than the noise floor measured with the conventional cryogenic current amplifiers based on high-electron-mobility transistors or superconducting quantum interference devices. Our proposal can open new avenues for investigating low-temperature solid-state devices that require lower noise and wider bandwidth power spectrum measurements of current.

arXiv:1508.03131•IEEE International Superconductive Electronics Conference (ISEC)•Jul 1, 2015•0 citations

Superconducting microstrip amplifiers with sub-Kelvin noise temperature near 4 GHz

M. P. DeFeo, B. L. T. Plourde

We present measurements of an amplifier operating at 3.8 GHz with 150 MHz of bandwidth based on the microstrip input-coil resonance of a dc superconducting quantum interference device (SQUID) with submicron Josephson junctions. The noise temperature is measured using two methods: comparing the signal-to-noise ratio of the system with and without the SQUID in the amplifier chain, and using a modified Y-factor technique where calibrated narrowband noise is mixed up to the SQUID amplifier operating frequency. With the SQUID cooled to 0.35 K, we observe a minimum system noise temperature of 0.55 ± 0.13 K, dominated by the contribution from the SQUID amplifier.

arXiv:1206.2235•Applied Physics Letters•Jul 30, 2012•11 citations

SIS junction as a microwave noise source

Hirofumi Inoue, Takashi Noguchi, Kotaro Kohno

Cooled low noise amplifier (LNA) is used as the first or second component of receiver system in radio astronomy. It is developed all over the world to improve its noise. Noise temperature is one of the most important parameters of LNA because it governs the observation time. It is usually measured by inputting two reference signal which have different power each other and measuring the responses. For accuracy, the power of these reference signals is required to be close to the noise of the LNA. In the conventional method output of a Avalanche diode is attenuated to 1/100 by a cold attenuator and used as a reference signal. In this method the error caused by the attenuator and the cable between the Avalanche diode and LNA is too large (a few 10 %) and another accurate noise measurement method is required. In this research we propose a new method using Superconductor-Insulator-Superconductor junction (SIS) as a reference signal. When biased, SIS generates small shot noise that is proportional to the bias voltage so it can be used as a reference signal that make an accurate noise measurement possible (a few % error). First, SIS and SIS housing is designed and fabricated for the shot noise to transmit without any loss and reflection. Then, noise temperature of the LNA is measured by using the conventional method and SIS shot noise method and compared. As a result, there was difference and it was shown that the capacitance of SIS is one of the candidate cause.

Journal of Physics Conference Series•Jun 1, 2010•3 citations

Noise sources and dissipation mechanisms of a 120 ℏ SQUID amplifier

P. Falferi, M. Bonaldi, Antonella Cavalleri +6 more

A two-stage superconducting quantum interference device (SQUID), based on a commercial sensor, is strongly coupled to an electrical resonator at 11 kHz with a quality factor Q=600 000 and operated in the temperature range 1.33–4.17 K. From the analysis of the noise generated by this system, the back action noise of the SQUID amplifier is estimated. The minimum noise temperature, calculated from back action and additive noise measurements, is 63 μK at 1.33 K, and corresponds to 120 times the quantum-limited noise temperature. We discuss and experimentally verify a mechanism, which can limit the noise temperature and add losses to the system.

Applied Physics Letters•Feb 10, 2003•10 citations

Superconducting quantum interference device as a near-quantum-limited amplifier at 0.5 GHz

Michael Mück, Jan B. Kycia, John L. Clarke

A dc superconducting quantum interference device (SQUID) with a resonant microstrip input is operated as an amplifier at temperatures down to 20 mK. A second SQUID is used as a postamplifier. Below about 100 mK, the noise temperature is 52±20 mK at 538 MHz, estimated from measurements of signal-to-noise ratio, and 47±10 mK at 519 MHz, estimated from the noise generated by a resonant circuit coupled to the input. The quantum-limited noise temperatures are 26 and 25 mK, respectively. The measured noise temperature is limited by hot electrons generated by the bias current.

Applied Physics Letters•Feb 12, 2001•118 citations
A method is developed to adapt the conventional definition of the noise temperature to amplifiers with superconducting inputs. In particular this method is applied to a crossed-film cryotron amplifier with a superconducting input to calculate its noise temperature. We then compare it with that of other amplifiers and masers. In addition to the noise temperature, a new criterion is evolved here: to estimate the figure of merit of amplifiers and detectors. This involves a new parameter called herein the action factor, which is the product of the smallest energy measurable by a device, with its smallest possible response time. The action factor and the noise temperature are worked out for the cryotron and a few other amplifiers and detectors for comparison. The advantage of the cryotron amplifier is brought out.
We introduce a new and quantitative theoretical framework for noise spectral analysis using a threshold detector, which is then applied to a superconducting device: the Josephson bifurcation amplifier. We show that this new framework provides direct access to the environmental noise spectrum with a sensitivity approaching the standard quantum limit of weak continuous measurements. In addition, the accessible frequency range of the spectrum is, in principle, limited only by the ring down time of the resonant mode. This on-chip noise detector is non-dissipative and works with low probing powers, allowing it to be operated at low temperatures ( mK). We exploit this technique for measuring the frequency fluctuations of our device and find a low frequency noise with an amplitude and spectrum compatible with a dielectric origin.
We propose a new type of cryogenic current amplifiers, in which low-frequency power spectrum of current can be measured through a measurement of microwave response of a superconducting resonant circuit shunted by a series array of Josephson junctions. From numerical analysis on the equivalent circuit, the numerical value of the input-referred current noise of the proposed amplifier is found to be two orders of magnitude lower than the noise floor measured with the conventional cryogenic current amplifiers based on high-electron-mobility transistors or superconducting quantum interference devices. Our proposal can open new avenues for investigating low-temperature solid-state devices that require lower noise and wider bandwidth power spectrum measurements of current.
We present measurements of an amplifier operating at 3.8 GHz with 150 MHz of bandwidth based on the microstrip input-coil resonance of a dc superconducting quantum interference device (SQUID) with submicron Josephson junctions. The noise temperature is measured using two methods: comparing the signal-to-noise ratio of the system with and without the SQUID in the amplifier chain, and using a modified Y-factor technique where calibrated narrowband noise is mixed up to the SQUID amplifier operating frequency. With the SQUID cooled to 0.35 K, we observe a minimum system noise temperature of 0.55 ± 0.13 K, dominated by the contribution from the SQUID amplifier.
Cooled low noise amplifier (LNA) is used as the first or second component of receiver system in radio astronomy. It is developed all over the world to improve its noise. Noise temperature is one of the most important parameters of LNA because it governs the observation time. It is usually measured by inputting two reference signal which have different power each other and measuring the responses. For accuracy, the power of these reference signals is required to be close to the noise of the LNA. In the conventional method output of a Avalanche diode is attenuated to 1/100 by a cold attenuator and used as a reference signal. In this method the error caused by the attenuator and the cable between the Avalanche diode and LNA is too large (a few 10 %) and another accurate noise measurement method is required. In this research we propose a new method using Superconductor-Insulator-Superconductor junction (SIS) as a reference signal. When biased, SIS generates small shot noise that is proportional to the bias voltage so it can be used as a reference signal that make an accurate noise measurement possible (a few % error). First, SIS and SIS housing is designed and fabricated for the shot noise to transmit without any loss and reflection. Then, noise temperature of the LNA is measured by using the conventional method and SIS shot noise method and compared. As a result, there was difference and it was shown that the capacitance of SIS is one of the candidate cause.
A two-stage superconducting quantum interference device (SQUID), based on a commercial sensor, is strongly coupled to an electrical resonator at 11 kHz with a quality factor Q=600 000 and operated in the temperature range 1.33–4.17 K. From the analysis of the noise generated by this system, the back action noise of the SQUID amplifier is estimated. The minimum noise temperature, calculated from back action and additive noise measurements, is 63 μK at 1.33 K, and corresponds to 120 times the quantum-limited noise temperature. We discuss and experimentally verify a mechanism, which can limit the noise temperature and add losses to the system.
A dc superconducting quantum interference device (SQUID) with a resonant microstrip input is operated as an amplifier at temperatures down to 20 mK. A second SQUID is used as a postamplifier. Below about 100 mK, the noise temperature is 52±20 mK at 538 MHz, estimated from measurements of signal-to-noise ratio, and 47±10 mK at 519 MHz, estimated from the noise generated by a resonant circuit coupled to the input. The quantum-limited noise temperatures are 26 and 25 mK, respectively. The measured noise temperature is limited by hot electrons generated by the bias current.