Excess phase noise has been observed in microwave kinetic inductance detectors (MKIDs) which prevents the noise-equivalent power (NEP) of current detectors from reaching theoretical limits. One characteristic of this excess noise is its dependence on the power of the readout signal: the phase noise decreases as the readout power increases. We investigated this power dependence in a variety of devices, varying the substrate (silicon and sapphire), superconductor (aluminum and niobium) and resonator parameters (resonant frequency, quality factor and resonator geometry). We find that the phase noise has a power law dependence on the readout power, and that the exponent is -1/2 in all our devices. We suggest that this phase noise is caused by coupling between the high-Q microwave resonator that forms the sensitive element of the MKID and two-level systems associated with disorder in the dielectric material of the resonator. The physical situation is analogous to the resonance fluorescence in quantum optics, and we are investigating the application of resonance fluorescence theory to MKID phase noise.
Excess phase noise has been observed in microwave kinetic inductance detectors (MKIDs) which prevents the noise-equivalent power (NEP) of current detectors from reaching theoretical limits. One characteristic of this excess noise is its dependence on the power of the readout signal: the phase noise decreases as the readout power increases. We investigated this power dependence in a variety of devices, varying the substrate (silicon and sapphire), superconductor (aluminum and niobium) and resonator parameters (resonant frequency, quality factor and resonator geometry). We find that the phase noise has a power law dependence on the readout power, and that the exponent is -1/2 in all our devices. We suggest that this phase noise is caused by coupling between the high-Q microwave resonator that forms the sensitive element of the MKID and two-level systems associated with disorder in the dielectric material of the resonator. The physical situation is analogous to the resonance fluorescence in quantum optics, and we are investigating the application of resonance fluorescence theory to MKID phase noise.
Microwave Kinetic Inductance Detectors (MKIDs) are extremely sensitive radiation detectors based on superconducting resonators that can be combined in large arrays on a single readout line within a limited frequency bandwidth. This makes MKIDs ideal detectors for the ultimate far-infrared observatory: a future space-based actively cooled telescope with its performance solely limited by the low universe background radiation. However, to reach these detector requirements, state-of-the-art MKIDs still need a order of magnitude improvement in device sensitivity. In this work, the MKID sensitivity is improved by reducing the aluminium volume that absorbs pair-breaking radiation into quasiparticle excitations, while making sure all radiation is still absorbed. Furthermore, a key requirement is sufficient reduction of excess noise as to keep the device intrinsically limited by thermally driven random fluctuations in the number of quasiparticles in absence of radiation, or Generation-Recombination (G-R) noise. To this end, a model is developed that describes the noise contributions as function of device geometry, readout power, material properties and radiation power. Subsequently, a realistic MKID design is presented and tested that reduces excess noise and maximises the sensitivity, expressed as Noise Equivalent Power (NEP). At high temperatures, good overall agreement is found between the measured noise spectra and the model. At low temperature T = 120 mK, the measurement results give an optical NEP similar to current state-of-the-art MKIDs. The NEP is not as low as expected due to short quasiparticle lifetimes, an unexpected decrease in the G-R noise level and a very high excess noise attributed to Two-Level Systems (TLS) noise that starts to dominate the already low G-R noise spectrum at low temperatures. Possibly, the quick quasiparticle lifetime saturation and noise level drop are caused by a strong readout power effect, as the readout power is known to create excess quasiparticles and to cause a strongly non-thermal electron energy distribution in the aluminium strip of the MKID. However, the exact microscopic details of these effects are unknown and not studied in this project. Based on the current chip design, a straightforward way to improve device performance and study the readout power effect in more detail is a reduction of the high TLS noise levels, which is possibly fabrication related. This would allow an unobstructed view of the G-R noise spectrum at low temperatures, thereby allowing both a study of the readout power effect on the quasiparticle system, and ultimately achieving the improvement in NEP needed reach the detector requirements for the ultimate space-based far-infrared observatory.
Microwave kinetic inductance detectors (MKIDs) are generally read out with microwave readout tones of high enough amplitude to adequately suppress the noise contribution of the first-stage amplifier. At high readout power, the detector's resonant frequency is altered as a result of the dependence of the kinetic inductance on the internally circulating microwave current. With the tone placed below the resonant frequency, the nonlinear frequency shift results in a positive feedback effect that can significantly enhance the responsivity of the detector, to both optical and microwave power. We report a factor of 10 enhancement in optical response by tuning the readout power and frequency to close to the resonator's bifurcation point. A corresponding decrease in the bandwidth of the resonator is observed under these conditions. We show that the strength of the feedback effect can be easily selected by adjusting the excitation, and provide a map of possible operational states to do so. Operation of MKIDs in this mode could be used to improve sensitivity when non-intrinsic noise sources are significant.
Abstract A microwave kinetic inductance detector (MKID) is a cutting-edge superconducting detector. It comprises a resonator circuit constructed with a superconducting film on a dielectric substrate. To expand its field of application, it is important to establish a method to suppress the two-level system (TLS) noise that is caused by the electric fluctuations between the two energy states at the surface of the substrate. The electric field density can be decreased by expanding the strip width (S) and gap width from the ground plane (W) in the MKID circuit, allowing the suppression of TLS noise. However, this effect has not yet been confirmed for MKIDs made with niobium films on silicon substrates. In this study, we demonstrate its effectiveness for such MKIDs. We expanded the dimension of the circuit from (S, W) = (3.00 μm, 4.00 μm) to (S, W) = (5.00 μm, 23.7 μm), and achieved an increased suppression of 5.5 dB in TLS noise.
Noise performance is one of the most crucial aspects of any detector. Superconducting Microwave Kinetic Inductance Detectors (MKIDs) have an “excess” frequency noise that shows up as a small time dependent jitter of the resonance frequency characterized by the frequency noise power spectrum measured in units of Hz2/Hz. Recent studies have shown that this noise almost certainly originates from a surface layer of two‐level system (TLS) defects on the metallization or substrate. Fluctuation of these TLSs introduces noise in the resonator due to coupling of the TLS electric dipole moments to the resonator’s electric field. Motivated by a semi‐empirical quantitative theory of this noise mechanism, we have designed and tested new resonator geometries in which the high‐field “capacitive” portion of the CPW resonator is replaced by an interdigitated capacitor (IDC) structure with 10–20 μm electrode spacing, as compared to the 2 μm spacing used for our more conventional CPW resonators. Measurements show that this new IDC design has dramatically lower TLS noise, currently by about a factor of ∼29 in terms of the frequency noise power spectrum, corresponding to an improvement of about a factor of 29 in NEP. These new devices are replacing the CPW resonators in our next design iteration in progress for MKIDCam. Opportunities and prospects for future reduction of the TLS noise will be discussed.
Microwave kinetic inductance detectors (MKID) are superconducting broadband direct detectors. If a superconducting thin film patterned into a resonator is illuminated with photons, Cooper pairs break up and the kinetic inductance of the film changes. This shifts the resonance frequency downwards and the dissipation of the resonator increases, which can be detected in the phase and amplitude of a transmitted signal. \n \nIn this thesis, a waveguide coupled MKID is designed and simulated. 350 GHz radiation is coupled into a copper waveguide via a horn antenna. A waveguide probe leads the signal onto a 9 µm silicon membrane where it is absorbed in a 40 nm superconducting aluminum film which is the inductive part of a superconducting resonator. The capacitor of the resonator is made of niobium. Two versions of the device are developed, a transmission line resonator and a lumped element resonator design. The new design will enable an accurate understanding of the optical sensitivity of MKIDs and allow comparison of different resonator materials. Since two different resonator types are used, the direct comparison of transmission line and lumped resonators will also be possible. \n \nA measurement setup is developed including an ADR cryostat to cool MKID devices down to below 40 mK. An analog readout system using either a vector network analyzer or an IQ mixer is designed and built. The necessary software to control the ADR, the temperature monitoring, the readout signal generation and detection and the signal acquisition of the setup is also developed. \n \nThe waveguide coupled MKID design is fabricated in our in-house microfabrication laboratory and measured in the new setup. In my measurements, the devices do not show a resonance feature. The VNA and DC measurements are analyzed to determine a plausible hypothesis of the failure. The devices are diagnosed for critical issues during fabrication which will be addressed in a future iteration. \n \nTo verify the measurement setup, a test device of the IRAM NIKA 2 MKID camera is measured and the complete analysis pipeline is exercised. The quasi-particle lifetime in the aluminum thin films is measured and a dark and optical noise equivalent power are determined. The results are within the uncertainty comparable to measurements of IRAM themselves. \n \nA test chip designed in my master thesis that contains eight NbTiN resonators is measured in the new setup and non-linear effects under strong readout power are studied. Parametric amplification and oscillation of a resonator are shown qualitatively.
Detectors employing superconducting microwave kinetic inductance detectors (MKIDs) can be read out by measuring changes in either the resonator frequency or dissipation. We will discuss the pros and cons of both methods, in particular, the readout method strategies being explored for the Multiwavelength Sub/millimeter Inductance Camera (MUSIC) to be commissioned at the CSO in 2010. As predicted theoretically and observed experimentally, the frequency responsivity is larger than the dissipation responsivity, by a factor of 2-4 under typical conditions. In the absence of any other noise contributions, it should be easier to overcome amplifier noise by simply using frequency readout. The resonators, however, exhibit excess frequency noise which has been ascribed to a surface distribution of two-level fluctuators sensitive to specific device geometries and fabrication techniques. Impressive dark noise performance has been achieved using modified resonator geometries employing interdigitated capacitors (IDCs). To date, our noise measurement and modeling efforts have assumed an onresonance readout, with the carrier power set well below the nonlinear regime. Several experimental indicators suggested to us that the optimal readout technique may in fact require a higher readout power, with the carrier tuned somewhat off resonance, and that a careful systematic study of the optimal readout conditions was needed. We will present the results of such a study, and discuss the optimum readout conditions as well as the performance that can be achieved relative to BLIP.