The fidelity of postselecting devices based on direct photon number detection can be significantly improved by insertion of a phase-insensitive optical amplifier in front of the detector. The scheme is simple, and the cost to the probability of obtaining the appropriate detector outcome is low.
We study the correspondence between classical and quantum measurements on a harmonic oscillator that describes a one-mode bosonic field with annihilation and creation operators a and a† with commutation [a, a†]=1. We connect the quantum measurement of an observable Ô=Ô (a, a†) of the field with the possibility of amplifying the observable Ô ideally through a quantum amplifier which achieves the Heisenberg-picture evolution Ô→ gÔ, where g is the gain of the amplifier. The "classical" measurement of Ô corresponds to the joint measurement of the position [Formula: see text] and momentum [Formula: see text] of the harmonic oscillator, with following evaluation of a function [Formula: see text] of the outcome α=q+ip. For the electromagnetic field the joint measurement is achieved by a heterodyne detector. The quantum measurement of Ô is obtained by preamplifying the heterodyne detector through an ideal amplifier of Ô and rescaling the outcome by the gain g. We give a general criterion which states when this preamplified heterodyne detection scheme approaches the ideal quantum measurement of Ô in the limit of infinite gain. We show that this criterion is satisfied and the ideal measurement is achieved for the case of the photon number operator a† a and for the quadrature [Formula: see text], where one measures the functions [Formula: see text] and [Formula: see text] of the field, respectively. For the photon number operator a† a the amplification scheme also achieves the transition from the continuous spectrum |α|2∈ℝ to the discrete one n∈ℕ of the operator a† a. Moreover, for both operators a† a and [Formula: see text] the method is robust to nonunit quantum efficiency of the heterodyne detector. On the other hand, we show that the preamplified heterodyne detection scheme does not work for arbitrary observable of the field. As a counterexample, we prove that the simple quadratic function of the field [Formula: see text] has no corresponding polynomial function [Formula: see text] — including the obvious choice f= Im (α2) — that allows the measurement of [Formula: see text] through the preamplified heterodyne measurement scheme.
We present a scheme for non-deterministically approximating photon number resolving detectors using non-discriminating detectors. The model is simple in construction and employs very few physical resources. Despite its non-determinism, the proposal may nonetheless be suitable for use in some quantum optics experiments in which non-determinism can be tolerated. We analyse the detection scheme in the context of an optical implementation of the controlled-NOT gate, an inherently non-deterministic device. This allows the gate's success probability to be traded away for improved gate fidelity, assuming high efficiency detectors. The scheme is compared to two other proposals, both deterministic, for approximating discriminating detectors using non-discriminating detectors: the cascade and time division multiplexing schemes.