Journal of the Optical Society of America B

Optical back-action-evading amplifiers

Bernard Yurke

Published May 1, 1985• 149 citations
Publisher

Abstract

A variety of optical back-action-evading amplification schemes are presented. Such amplifiers allow one to measure the amplitude of one component of an optical field mode without disturbing that component.
DOI
10.1364/josab.2.000732

Related papers

Back action evading measurements of a classical signal involving a dichromatic probe

Andrey B. Matsko

Optical and Quantum Sensing and Precision Metrology II•Mar 8, 2023•0 citations

Broadband quantum back action evading measurements of a resonant force

Sergey P. Vyatchanin, Andrey B. Matsko

Physics Letters A•Nov 19, 2021•0 citations

Advanced implementations of phase sensitive amplifiers

Francesca R. Parmigiani, Graham Hesketh, Kyle R. H. Bottrill +4 more

We review our recent results on different configurations of phase sensitive amplifiers that achieve all-optical phase regeneration and optical phase quantization at low nonlinear phase shifts.

IEEE/LEOS Summer Topical Meetings•Jul 1, 2014•0 citations

Back-action-evading measurement of optical fields with the use of a four-wave mixer

Bernard Yurke, L. R. Corruccini

Recent investigations on the ultimate sensitivity of gravitational-wave detectors have led to a new measurement strategy known as "back-action evasion" which allows one to measure precisely one component of an oscillator's motion without disturbing that component. This detection strategy can be carried out on electromagnetic field modes as well. Here a scheme, using a degenerate four-wave mixer, is presented for carrying out back-action-evading measurements on optical field modes.

Physical Review A•Aug 1, 1984•8 citations

Phase-Sensitive Detection and the Back-Action Evasion of Amplifier Force Noise (Measurement Theory, Transducers, Antenna, Gravitational Radiation, Accelerometer).

Gary W. Spetz

Limitations on the sensitivity for detecting a weak classical force acting on a harmonic oscillator are imposed by the quantum mechanical properties associated with a "standard" amplitude-and-phase measurement and, classically, by the back reaction noise associated with the finite noise temperature of the amplifier used to process the measurement. These are known as the "standard quantum limit" and the "standard amplifier limit", respectively. We present the theoretical motivation behind the quest to circumvent these limits, and examine a single-transducer back-action evading measurement scheme designed to perform a phase-sensitive coupling to the oscillator, with the concomitant circumvention of the standard amplifier limit via the "squeezing" of amplifier back reaction noise. The applicability of squeezing in the detection of gravitational radiation is explored via the dependence of detection sensitivity on the physical temperature and quality factor of the resonant-bar gravitational radiation antenna, on the noise temperature of the amplifier, and on the squeezing factor of the back-action evading measurement; the success of back-action evasion in improving upon the optimum amplitude-and-phase detection sensitivities depends critically upon these parameters. Using the LSU superconducting dual-cavity accelerometer as a test platform, we present direct evidence for the establishment of a phase-sensitive coupling to an oscillator, along with a variety of indirect corroborating evidence. This data indicates that our phase-sensitive measurement scheme is indeed more sensitive to one component of the oscillator than to the other component. We also present the first evidence for the existence of back-action evasion of amplifier back reaction noise. We show theoretical expectations and experimental results for the dependence of squeezing on: input signal phases, amplitudes, and frequencies; amplifier back reaction levels; background noise; mechanical oscillator frequency; and coherent carrier contribution at the cavity resonance frequency. Squeezing factors of up to fifteen were achieved by our back-action evading measurement scheme.

Civil War Book Review•Jan 1, 1985•0 citations

Using an Optical Parametric Amplifier as a Noiseless Attenuator

R. A. Brewster, J. D. Franson

Bulletin of the American Physical Society•Mar 8, 2018•0 citations
Limitations on the sensitivity for detecting a weak classical force acting on a harmonic oscillator are imposed by the quantum mechanical properties associated with a "standard" amplitude-and-phase measurement and, classically, by the back reaction noise associated with the finite noise temperature of the amplifier used to process the measurement. These are known as the "standard quantum limit" and the "standard amplifier limit", respectively. We present the theoretical motivation behind the quest to circumvent these limits, and examine a single-transducer back-action evading measurement scheme designed to perform a phase-sensitive coupling to the oscillator, with the concomitant circumvention of the standard amplifier limit via the "squeezing" of amplifier back reaction noise. The applicability of squeezing in the detection of gravitational radiation is explored via the dependence of detection sensitivity on the physical temperature and quality factor of the resonant-bar gravitational radiation antenna, on the noise temperature of the amplifier, and on the squeezing factor of the back-action evading measurement; the success of back-action evasion in improving upon the optimum amplitude-and-phase detection sensitivities depends critically upon these parameters. Using the LSU superconducting dual-cavity accelerometer as a test platform, we present direct evidence for the establishment of a phase-sensitive coupling to an oscillator, along with a variety of indirect corroborating evidence. This data indicates that our phase-sensitive measurement scheme is indeed more sensitive to one component of the oscillator than to the other component. We also present the first evidence for the existence of back-action evasion of amplifier back reaction noise. We show theoretical expectations and experimental results for the dependence of squeezing on: input signal phases, amplitudes, and frequencies; amplifier back reaction levels; background noise; mechanical oscillator frequency; and coherent carrier contribution at the cavity resonance frequency. Squeezing factors of up to fifteen were achieved by our back-action evading measurement scheme.