In quantum mechanics, the act of measurement perturbs the system by adding noise that usually contaminates subsequent measurements of the observable in question.
We show that the two-level systems (TLS) in lithographic superconducting circuits act as a power-dependent dielectric leading to non-linear responses in a parametrically coupled electromechanical system. Driven TLS shift the microwave resonance frequency and modulate the mechanical resonance through the optical spring effect. By pumping with two tones in a back-action evading measurement, these effects produce a mechanical parametric instability which limits single quadrature imprecision to 1.4 xzp. The microwave resonator noise is also consistent to a TLS-noise model. These observations suggest design strategies for minimizing TLS effects to improve ground-state cooling and quantum non-demolition measurements of motion.
The high-sensitivity quantum detection of a resonant classical force acting on a quantum harmonic oscillator can be significantly improved by employing a resonant optical parametric transducer. This technique leverages the unique properties of parametric interactions to enhance the response of the measurement system while maintaining quantum-limited performance. We demonstrate that such a configuration not only enables quantum back-action evading (BAE) measurements, surpassing the Standard Quantum Limit (SQL) of sensitivity, it also provides a mechanism for noiseless amplification of the classical signal. The key to this enhancement lies in the ability of the parametric transducer to generate and separately measure the upper and lower modulation sidebands induced by the external force. By decoupling and analyzing these sidebands independently, the system becomes capable of amplifying the signal without introducing additional noise, effectively circumventing quantum measurement constraints.