Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Communications

Transverse relaxation of cesium vapour in a “strong” resonance radio frequency field

Wojciech Skubiszak, K. Rosiński

Published Oct 1, 1977• 2 citations
Publisher
DOI
10.1016/0030-4018(77)90124-9

Related papers

Generation and control of high-order harmonics in a cesium-atom magnetic-resonance system under strong radio-frequency driving

Ao-dong Xie, Xu‐xing Geng, Wangwang Tang +6 more

Physical Review A•Jul 9, 2026•0 citations

⇄Sz↩ and ⇄S+↩ relaxation in optically pumped cesium vapour

A. Sieradzan, Jozef Dresner, K. Rosiński

Optics Communications•Apr 1, 1976•5 citations

Investigation on the methods to extend the transverse relaxation time of polarized alkali atoms

Yang-Ying Fu, Jie Yuan

In order to improve the sensitivity of radio-frequency atomic magnetometer, two methods to extend the transverse relaxation time of polarized alkali atoms are investigated. One way is the application of a non-relaxing coating, another way is the introduction of buffer gas into cell. A theory relaxation model is built, and the dependences of transverse relaxation time on buffer gas pressure, laser power, cell temperature, and magnetic-field gradient are obtained. The measurements of transverse relaxation time are carried out in a cesium atomic radio-frequency magnetometer. The optical experiment conditions which yield the highest sensitivity are determined in experiments. Experiments results indicate that the optimal pressure for neon is 200 Torr. The experimental results are in agreement with the theoretical ones. An ultimate sensitivity of 100 fT/Hz1/2 of the cesium atomic radio-frequency magnetometer has been achieved. This study helps further optimization of the cell performance and the sensitivity of radio-frequency atomic magnetometer.

National Conference on Laser Technology and Optoelectronics (LTO)•May 17, 2019•0 citations

The Transport of Resonance Radiation in Cesium Vapor.

Felix T. Ullrich

•Jan 1, 1970•0 citations

Light narrowing of cesium magnetic-resonance lines in a radio-frequency atomic magnetometer

Y. Fu, Xiaohu Liu, Jie Yuan

The magnetic-resonance lines of alkali atoms are broadened considerably by the spin-exchange collisions for a radio-frequency magnetometer operating at high temperature. The resonance linewidths of cesium atoms are derived by solving the relaxation equations. When spin-exchange relaxation dominates, a light narrowing effect is predicted. For the cesium atomic radio-frequency magnetometer operates at high temperature, a remarkable narrowing of the cesium magnetic-resonance lines are observed by increasing the pump power. The Cs-Cs spin-exchange relaxation is partially suppressed by light narrowing. This study helps to expand the applications of radio-frequency magnetometers in the high-sensitivity radio-frequency magnetic-field detection.

AIP Advances•Jan 1, 2019•10 citations

Transverse relaxation in two-level Fermi liquids and gases

Karen A. Musaelian, A. E. Meyerovich

Journal of Low Temperature Physics•Nov 1, 1992•3 citations
In order to improve the sensitivity of radio-frequency atomic magnetometer, two methods to extend the transverse relaxation time of polarized alkali atoms are investigated. One way is the application of a non-relaxing coating, another way is the introduction of buffer gas into cell. A theory relaxation model is built, and the dependences of transverse relaxation time on buffer gas pressure, laser power, cell temperature, and magnetic-field gradient are obtained. The measurements of transverse relaxation time are carried out in a cesium atomic radio-frequency magnetometer. The optical experiment conditions which yield the highest sensitivity are determined in experiments. Experiments results indicate that the optimal pressure for neon is 200 Torr. The experimental results are in agreement with the theoretical ones. An ultimate sensitivity of 100 fT/Hz1/2 of the cesium atomic radio-frequency magnetometer has been achieved. This study helps further optimization of the cell performance and the sensitivity of radio-frequency atomic magnetometer.
The magnetic-resonance lines of alkali atoms are broadened considerably by the spin-exchange collisions for a radio-frequency magnetometer operating at high temperature. The resonance linewidths of cesium atoms are derived by solving the relaxation equations. When spin-exchange relaxation dominates, a light narrowing effect is predicted. For the cesium atomic radio-frequency magnetometer operates at high temperature, a remarkable narrowing of the cesium magnetic-resonance lines are observed by increasing the pump power. The Cs-Cs spin-exchange relaxation is partially suppressed by light narrowing. This study helps to expand the applications of radio-frequency magnetometers in the high-sensitivity radio-frequency magnetic-field detection.