National Conference on Laser Technology and Optoelectronics (LTO)

Investigation on the methods to extend the transverse relaxation time of polarized alkali atoms

Yang-Ying Fu, Jie Yuan

Published May 17, 2019• 0 citations
Publisher

Abstract

In order to improve the sensitivity of radio-frequency atomic magnetometer, two methods to extend the transverse relaxation time of polarized alkali atoms are investigated. One way is the application of a non-relaxing coating, another way is the introduction of buffer gas into cell. A theory relaxation model is built, and the dependences of transverse relaxation time on buffer gas pressure, laser power, cell temperature, and magnetic-field gradient are obtained. The measurements of transverse relaxation time are carried out in a cesium atomic radio-frequency magnetometer. The optical experiment conditions which yield the highest sensitivity are determined in experiments. Experiments results indicate that the optimal pressure for neon is 200 Torr. The experimental results are in agreement with the theoretical ones. An ultimate sensitivity of 100 fT/Hz1/2 of the cesium atomic radio-frequency magnetometer has been achieved. This study helps further optimization of the cell performance and the sensitivity of radio-frequency atomic magnetometer.

DOI
10.1117/12.2532465

Related papers

Intrinsic transverse relaxation mechanisms of polarized alkali atoms enclosed in radio-frequency magnetometer cell*

Yang-Ying Fu, Jie Yuan

The intrinsic transverse relaxation mechanisms of polarized alkali atoms enclosed in the radio-frequency magnetometer cell are investigated. The intrinsic transverse relaxation rate of cesium atoms as a function of cell temperature is obtained. The absorption of alkali atoms by the glass wall and the reservoir effect are the main error factors which contribute to the disagreements between theory and experiments. A modified relaxation model is presented, in which both the absorption of alkali atoms by the glass wall and the reservoir effect are included. This study provides a more accurate description of the intrinsic transverse relaxation mechanisms of polarized alkali atoms, and enlightens the optimization of the cell design.

Chinese Physics B•Jul 24, 2019•8 citations

Buffer Gas Pressure Optimization for Atomic Spin Relaxation Suppression in Ultra-High-Sensitivity SERF Magnetometers

Siran Li, X.-G. Lu, Yinghui Zhang +3 more

Optically pumped magnetometers (OPM) are core quantum payloads for geomagnetic remote sensing. Among them, the spin-exchange relaxation-free (SERF) OPM with aT-level ultimate sensitivity stands as mainstream. While enlarging the alkali-metal vapor cell of the SERF OPM enhances sensitivity, it triggers complex atomic spin relaxation, notably intensified magnetic field gradient relaxation. To address the dilemma of atomic spin relaxation regulation and the engineering requirements of ultra-high-sensitivity SERF magnetometers, this paper constructs an analytical model of the total relaxation rate that comprehensively considers wall-collision relaxation, spin-destruction collision relaxation, and longitudinal/transverse magnetic field gradient relaxation, etc. The analytical relationship between buffer gas pressure and total relaxation rate for a commonly used spherical vapor cell is derived, revealing the intrinsic correlation among cell size, atomic spin relaxation, and optimal pressure. Based on the theoretical model, the filling parameters of the vapor cell are optimized, and experimental measurements are carried out. The theoretical relaxation results are highly consistent with the experimental ones, realizing the precise optimization of buffer gas pressure. The optimization method proposed in this paper provides a theoretical basis and parameter guidance for the engineering preparation of alkali-metal vapor cells for high-sensitivity SERF magnetometers in remote sensing applications.

Photonics•Jun 1, 2026•0 citations

The influence of longitudinal magnetic-field gradient on the transverse relaxation rate of cesium atoms

Y. Fu, Jiayue Yuan

Reducing the transverse relaxation rate of alkali atoms is crucial to improve the sensitivity of the magnetometers. In a perturbative treatment of the effects of the magnetic-field gradients, the transverse relaxation rates of alkali atoms are predicted to be proportional to the square of the longitudinal magnetic-field gradient. The theoretical predictions are confirmed in our experiments. The magnetic-field gradients in the vapor cell are measured by experiments. The magnetic-field gradient in the cell is suppressed drastically through compensating it with the compensation coils. Experimental results show that suppressing the magnetic-field gradient can reduce the transverse relaxation rate of alkali atoms significantly. This study contributes to the development of ultra-high sensitivity alkali atomic magnetometers.

AIP Advances•Nov 1, 2017•9 citations

Influence of Buffer-Gas Pressure Inside Micro Alkali Vapor Cells on the Performance of Chip-Scale SERF Magnetometers

Lei Wu, Jintang Shang, Yu Ji +2 more

Spin-exchange-relaxation-free (SERF) optical atomic magnetometers are facing the challenges of dramatic decrease of sensitivity when the alkali vapor cells become small. This paper focuses on the sensitivity improvement of the chip-scale atomic magnetometer (CSAM) by changing buffer-gas pressures inside the microfabricated vapor cells. The rubidium vapor cells with three different buffer-gas pressures were tested in the SERF magnetometer. The influences of vapor cell temperature and pumping laser power on the device sensitivity are also characterized for further optimization. Results show that the three atomic vapor cells, with N2buffer-gas pressure of 0.20, 0.88, and 2.35 amg, have sensitivities of 900, 500, and 150 fT/Hz1/2, respectively. Results indicated that when the alkali vapor cells continue to be smaller, high buffer-gas pressure would provide an effective way to reduce the wall collision and improve the performance of CSAMs.

IEEE Transactions on Components Packaging and Manufacturing Technology•Dec 21, 2017•18 citations

Study of resonance curve width in Cs vapor magnetometer

Sun Weimin

A new magnetometer with Cs vapor in the spin exchange relaxation free(SERF) regime is described.Cs has a higher saturated vapor pressure than other alkali metals;so cesium SERF magnetometer is particularly attractive in applications that require lower power dissipation.Four factors affect atomic transverse relaxations in the SERF magnetometer,including collisions and diffusions among Cs,N2 and He,laser pumping and detecting processes;the buffer gas pressure of He that affects the relaxation is calculated and discussed emphatically in theory at 105 ℃,the result shows that the optimum buffer gas pressure is 350×133.3 Pa.Under the optimum pressure,the polarized spectrum linewidth as the function of the cell temperature is discussed briefly.It is found the least linewidth is only 3.7 Hz corresponding to the electric spin relaxation rate of 278 s-1 at 105 ℃.The result provides a help to increase the sensitivity of the magnetometer with Cs vapor.

Journal of Optoelectronics·laser•Jan 1, 2010•0 citations

Three techniques for measuring the transverse relaxation time of cesium atoms

Mengmeng Wei, Wenbin Yu, Min Zhou +3 more

The transverse relaxation time (T2) is an important indicator to determine the fundamental sensitivity limit of alkali-metal atomic magnetometers. We propose a method based on the principle of longitudinal field modulation that obtains T2 by scanning the transverse static magnetic field. The previous technique of extracting T2 from the linewidth of the modulation frequency and the traditional magnetic-resonance-broadening-fitting method are also described. The T2 measurements of Cesium (Cs) atoms are carried out through these three methods, whose operating environments are applicable to different atomic magnetometers, respectively. The method that we propose can be used for obtaining the T2 of Cs atoms as well as detecting the transverse static magnetic field and is customized for the study of the Cs–Xenon ensemble for the construction of nuclear magnetic resonance gyroscopes. Moreover, the relationship between the limit sensitivities and cell temperatures is further studied in the experiment.

AIP Advances•Mar 1, 2023•4 citations
In order to improve the sensitivity of radio-frequency atomic magnetometer, two methods to extend the transverse relaxation time of polarized alkali atoms are investigated. One way is the application of a non-relaxing coating, another way is the introduction of buffer gas into cell. A theory relaxation model is built, and the dependences of transverse relaxation time on buffer gas pressure, laser power, cell temperature, and magnetic-field gradient are obtained. The measurements of transverse relaxation time are carried out in a cesium atomic radio-frequency magnetometer. The optical experiment conditions which yield the highest sensitivity are determined in experiments. Experiments results indicate that the optimal pressure for neon is 200 Torr. The experimental results are in agreement with the theoretical ones. An ultimate sensitivity of 100 fT/Hz1/2 of the cesium atomic radio-frequency magnetometer has been achieved. This study helps further optimization of the cell performance and the sensitivity of radio-frequency atomic magnetometer.
The intrinsic transverse relaxation mechanisms of polarized alkali atoms enclosed in the radio-frequency magnetometer cell are investigated. The intrinsic transverse relaxation rate of cesium atoms as a function of cell temperature is obtained. The absorption of alkali atoms by the glass wall and the reservoir effect are the main error factors which contribute to the disagreements between theory and experiments. A modified relaxation model is presented, in which both the absorption of alkali atoms by the glass wall and the reservoir effect are included. This study provides a more accurate description of the intrinsic transverse relaxation mechanisms of polarized alkali atoms, and enlightens the optimization of the cell design.
Optically pumped magnetometers (OPM) are core quantum payloads for geomagnetic remote sensing. Among them, the spin-exchange relaxation-free (SERF) OPM with aT-level ultimate sensitivity stands as mainstream. While enlarging the alkali-metal vapor cell of the SERF OPM enhances sensitivity, it triggers complex atomic spin relaxation, notably intensified magnetic field gradient relaxation. To address the dilemma of atomic spin relaxation regulation and the engineering requirements of ultra-high-sensitivity SERF magnetometers, this paper constructs an analytical model of the total relaxation rate that comprehensively considers wall-collision relaxation, spin-destruction collision relaxation, and longitudinal/transverse magnetic field gradient relaxation, etc. The analytical relationship between buffer gas pressure and total relaxation rate for a commonly used spherical vapor cell is derived, revealing the intrinsic correlation among cell size, atomic spin relaxation, and optimal pressure. Based on the theoretical model, the filling parameters of the vapor cell are optimized, and experimental measurements are carried out. The theoretical relaxation results are highly consistent with the experimental ones, realizing the precise optimization of buffer gas pressure. The optimization method proposed in this paper provides a theoretical basis and parameter guidance for the engineering preparation of alkali-metal vapor cells for high-sensitivity SERF magnetometers in remote sensing applications.
Reducing the transverse relaxation rate of alkali atoms is crucial to improve the sensitivity of the magnetometers. In a perturbative treatment of the effects of the magnetic-field gradients, the transverse relaxation rates of alkali atoms are predicted to be proportional to the square of the longitudinal magnetic-field gradient. The theoretical predictions are confirmed in our experiments. The magnetic-field gradients in the vapor cell are measured by experiments. The magnetic-field gradient in the cell is suppressed drastically through compensating it with the compensation coils. Experimental results show that suppressing the magnetic-field gradient can reduce the transverse relaxation rate of alkali atoms significantly. This study contributes to the development of ultra-high sensitivity alkali atomic magnetometers.
Spin-exchange-relaxation-free (SERF) optical atomic magnetometers are facing the challenges of dramatic decrease of sensitivity when the alkali vapor cells become small. This paper focuses on the sensitivity improvement of the chip-scale atomic magnetometer (CSAM) by changing buffer-gas pressures inside the microfabricated vapor cells. The rubidium vapor cells with three different buffer-gas pressures were tested in the SERF magnetometer. The influences of vapor cell temperature and pumping laser power on the device sensitivity are also characterized for further optimization. Results show that the three atomic vapor cells, with N2buffer-gas pressure of 0.20, 0.88, and 2.35 amg, have sensitivities of 900, 500, and 150 fT/Hz1/2, respectively. Results indicated that when the alkali vapor cells continue to be smaller, high buffer-gas pressure would provide an effective way to reduce the wall collision and improve the performance of CSAMs.
A new magnetometer with Cs vapor in the spin exchange relaxation free(SERF) regime is described.Cs has a higher saturated vapor pressure than other alkali metals;so cesium SERF magnetometer is particularly attractive in applications that require lower power dissipation.Four factors affect atomic transverse relaxations in the SERF magnetometer,including collisions and diffusions among Cs,N2 and He,laser pumping and detecting processes;the buffer gas pressure of He that affects the relaxation is calculated and discussed emphatically in theory at 105 ℃,the result shows that the optimum buffer gas pressure is 350×133.3 Pa.Under the optimum pressure,the polarized spectrum linewidth as the function of the cell temperature is discussed briefly.It is found the least linewidth is only 3.7 Hz corresponding to the electric spin relaxation rate of 278 s-1 at 105 ℃.The result provides a help to increase the sensitivity of the magnetometer with Cs vapor.
The transverse relaxation time (T2) is an important indicator to determine the fundamental sensitivity limit of alkali-metal atomic magnetometers. We propose a method based on the principle of longitudinal field modulation that obtains T2 by scanning the transverse static magnetic field. The previous technique of extracting T2 from the linewidth of the modulation frequency and the traditional magnetic-resonance-broadening-fitting method are also described. The T2 measurements of Cesium (Cs) atoms are carried out through these three methods, whose operating environments are applicable to different atomic magnetometers, respectively. The method that we propose can be used for obtaining the T2 of Cs atoms as well as detecting the transverse static magnetic field and is customized for the study of the Cs–Xenon ensemble for the construction of nuclear magnetic resonance gyroscopes. Moreover, the relationship between the limit sensitivities and cell temperatures is further studied in the experiment.