Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Photonics

Buffer Gas Pressure Optimization for Atomic Spin Relaxation Suppression in Ultra-High-Sensitivity SERF Magnetometers

Siran Li, X.-G. Lu, Yinghui Zhang, Yafang Zou, Yanning Ma, Li Cao

Published Jun 1, 2026• 0 citations
Publisher

Abstract

Optically pumped magnetometers (OPM) are core quantum payloads for geomagnetic remote sensing. Among them, the spin-exchange relaxation-free (SERF) OPM with aT-level ultimate sensitivity stands as mainstream. While enlarging the alkali-metal vapor cell of the SERF OPM enhances sensitivity, it triggers complex atomic spin relaxation, notably intensified magnetic field gradient relaxation. To address the dilemma of atomic spin relaxation regulation and the engineering requirements of ultra-high-sensitivity SERF magnetometers, this paper constructs an analytical model of the total relaxation rate that comprehensively considers wall-collision relaxation, spin-destruction collision relaxation, and longitudinal/transverse magnetic field gradient relaxation, etc. The analytical relationship between buffer gas pressure and total relaxation rate for a commonly used spherical vapor cell is derived, revealing the intrinsic correlation among cell size, atomic spin relaxation, and optimal pressure. Based on the theoretical model, the filling parameters of the vapor cell are optimized, and experimental measurements are carried out. The theoretical relaxation results are highly consistent with the experimental ones, realizing the precise optimization of buffer gas pressure. The optimization method proposed in this paper provides a theoretical basis and parameter guidance for the engineering preparation of alkali-metal vapor cells for high-sensitivity SERF magnetometers in remote sensing applications.

DOI
10.3390/photonics13060546

Related papers

Influence of Buffer-Gas Pressure Inside Micro Alkali Vapor Cells on the Performance of Chip-Scale SERF Magnetometers

Lei Wu, Jintang Shang, Yu Ji +2 more

Spin-exchange-relaxation-free (SERF) optical atomic magnetometers are facing the challenges of dramatic decrease of sensitivity when the alkali vapor cells become small. This paper focuses on the sensitivity improvement of the chip-scale atomic magnetometer (CSAM) by changing buffer-gas pressures inside the microfabricated vapor cells. The rubidium vapor cells with three different buffer-gas pressures were tested in the SERF magnetometer. The influences of vapor cell temperature and pumping laser power on the device sensitivity are also characterized for further optimization. Results show that the three atomic vapor cells, with N2buffer-gas pressure of 0.20, 0.88, and 2.35 amg, have sensitivities of 900, 500, and 150 fT/Hz1/2, respectively. Results indicated that when the alkali vapor cells continue to be smaller, high buffer-gas pressure would provide an effective way to reduce the wall collision and improve the performance of CSAMs.

IEEE Transactions on Components Packaging and Manufacturing Technology•Dec 21, 2017•18 citations

Optimized gas pressure of an Rb vapor cell in a single-beam SERF magnetometer

Yaxiang Wang, Ge Jin, Junjian Tang +4 more

We present a theoretical and experimental study of a single-beam spin-exchange relaxation-free magnetometer in 87Rb vapor cells under different nitrogen gas pressures. The spin relaxation rate is a key component to limit the magnetic sensitivity, and the zero-field resonance method was used to measure the spin relaxation rates of different alkali metal cells. Simultaneously, in a single-beam spin-exchange-relaxation-free (SERF) magnetometer, we demonstrated that the fundamental magnetic field sensitivity was also limited by the pumping light intensity. Based on our theoretical analysis and experimental results, we determined the optimal pumping light intensity and optimal gas pressure. We experimentally demonstrated that the magnetic field sensitivity was 8.89 fT / Hz in the single-beam configuration, with an active measurement volume of 3 × 3 × 3~mm3.

Optics Express•Dec 15, 2021•42 citations

Study of resonance curve width in Cs vapor magnetometer

Sun Weimin

A new magnetometer with Cs vapor in the spin exchange relaxation free(SERF) regime is described.Cs has a higher saturated vapor pressure than other alkali metals;so cesium SERF magnetometer is particularly attractive in applications that require lower power dissipation.Four factors affect atomic transverse relaxations in the SERF magnetometer,including collisions and diffusions among Cs,N2 and He,laser pumping and detecting processes;the buffer gas pressure of He that affects the relaxation is calculated and discussed emphatically in theory at 105 ℃,the result shows that the optimum buffer gas pressure is 350×133.3 Pa.Under the optimum pressure,the polarized spectrum linewidth as the function of the cell temperature is discussed briefly.It is found the least linewidth is only 3.7 Hz corresponding to the electric spin relaxation rate of 278 s-1 at 105 ℃.The result provides a help to increase the sensitivity of the magnetometer with Cs vapor.

Journal of Optoelectronics·laser•Jan 1, 2010•0 citations

Optimizing longitudinal spin relaxation in miniaturized optically pumped magnetometers

A. McWilliam, S. Dyer, Dominic Hunter +7 more

The microfabrication of cesium vapor cells for optically pumped magnetometry relies on optimization of buffer gas pressure in order to maximize atomic coherence time and sensitivity to external magnetic signals. We demonstrate post-bond nitrogen buffer gas pressure tuning through localized heating of an integrated micropill dispenser. We characterize the variation in the intrinsic longitudinal relaxation rate, γ 10 , and magnetic sensitivity, as a function of the resulting nitrogen buffer gas pressure. Measurements are conducted by employing an optically pumped magnetometer operating in a free-induction-decay configuration. γ 10 is extracted across a range of nitrogen pressures between 60 and 700 torr, measuring a minimum of 140 Hz at 115 torr. In addition, we achieve sensitivities as low as 130 fT / Hz at a bias field amplitude of about 50 μ T . With the optimal nitrogen buffer gas pressure now quantified and achievable post-fabrication, these mass-producible cells can be tailored to suit a variety of sensing applications, ensuring peak magnetometer performance. Published by the American Physical Society 2024

arXiv:2406.19178•Physical Review Applied•Dec 5, 2024•9 citations

Coating-Enabled Buffer-Gas-Free Vapor Cell: A New Sensor Architecture for Single-Beam SERF Magnetometers

Yi-an Xu, Yuhao Wang, Jiaxin Liu +5 more

Alkali metal vapor cells are fundamental components in quantum sensors, and their relaxation characteristics critically influence both sensitivity and system stability. In Spin-Exchange Relaxation-Free (SERF) atomic magnetometers, although spin-exchange collisions are effectively suppressed, wall-collision-induced relaxation remains the primary limiting factor. A coating-enabled buffer-gas-free vapor cell (CBF-VC) is proposed as a novel sensor unit, realized through multilayer octadecyltrichlorosilane (OTS) selfassembled molecular coatings. The CBF-VC is integrated into a single-beam SERF atomic magnetometer, and experimental validation is conducted. The results indicate a significant extension of the wall collision relaxation time from 40.19 ms. This extended relaxation time directly enhances the magnetometer sensitivity by 48%, confirming the feasibility of CBF-VCs as a measurement-oriented vapor cell architecture. The findings demonstrate not only the effectiveness of anti-relaxation coatings, but also a new instrumentation pathway for advancing next-generation quantum sensing.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2026•0 citations

The Characterization of Atomic Vapor Cells for High-Sensitivity Magnetic Field Measurements in SERF Regime

Murat Salim Karabinaoğlu, Berfin Muhlise Caklı, Mehmet Hüseyin Sevim

Nowadays, quantum sensor research is a very interesting and popular topic. High-sensitivity magnetic field measurements using quantum sensors have evolved into the most sensitive magnetic field sensor category today with the invention of atomic magnetometers operating in the spin-exchange relaxation-free (SERF) regime. This letter was prepared to investigate the magnetic field sensitivity changes depending on the buffer gas, temperature, and laser intensity using indigenously produced atomic vapor cells. In addition, the aim was to determine the optimum operating conditions of the atomic magnetometer operating in the SERF regime. As a result, the resonance linewidth and signal-to-noise ratio were measured, and the minimum detectable magnetic field was calculated. According to the obtained results, the lowest magnetic field for Cells I–III was measured as 5.12, 4.21, and 4.81 pT, respectively. The lowest magnetic field of all conditions was obtained in vapor cell (Cell-II) at 100 °C with 5 mW laser intensity. As a result, it has been experimentally proven that under the same conditions, increasing the buffer gas pressure in vapor cells can narrow the resonance linewidth, and the magnetic field sensitivity can be improved by increasing the laser intensity applied to the vapor cells.

IEEE Sensors Letters•Feb 24, 2025•5 citations
Optically pumped magnetometers (OPM) are core quantum payloads for geomagnetic remote sensing. Among them, the spin-exchange relaxation-free (SERF) OPM with aT-level ultimate sensitivity stands as mainstream. While enlarging the alkali-metal vapor cell of the SERF OPM enhances sensitivity, it triggers complex atomic spin relaxation, notably intensified magnetic field gradient relaxation. To address the dilemma of atomic spin relaxation regulation and the engineering requirements of ultra-high-sensitivity SERF magnetometers, this paper constructs an analytical model of the total relaxation rate that comprehensively considers wall-collision relaxation, spin-destruction collision relaxation, and longitudinal/transverse magnetic field gradient relaxation, etc. The analytical relationship between buffer gas pressure and total relaxation rate for a commonly used spherical vapor cell is derived, revealing the intrinsic correlation among cell size, atomic spin relaxation, and optimal pressure. Based on the theoretical model, the filling parameters of the vapor cell are optimized, and experimental measurements are carried out. The theoretical relaxation results are highly consistent with the experimental ones, realizing the precise optimization of buffer gas pressure. The optimization method proposed in this paper provides a theoretical basis and parameter guidance for the engineering preparation of alkali-metal vapor cells for high-sensitivity SERF magnetometers in remote sensing applications.
Spin-exchange-relaxation-free (SERF) optical atomic magnetometers are facing the challenges of dramatic decrease of sensitivity when the alkali vapor cells become small. This paper focuses on the sensitivity improvement of the chip-scale atomic magnetometer (CSAM) by changing buffer-gas pressures inside the microfabricated vapor cells. The rubidium vapor cells with three different buffer-gas pressures were tested in the SERF magnetometer. The influences of vapor cell temperature and pumping laser power on the device sensitivity are also characterized for further optimization. Results show that the three atomic vapor cells, with N2buffer-gas pressure of 0.20, 0.88, and 2.35 amg, have sensitivities of 900, 500, and 150 fT/Hz1/2, respectively. Results indicated that when the alkali vapor cells continue to be smaller, high buffer-gas pressure would provide an effective way to reduce the wall collision and improve the performance of CSAMs.
We present a theoretical and experimental study of a single-beam spin-exchange relaxation-free magnetometer in 87Rb vapor cells under different nitrogen gas pressures. The spin relaxation rate is a key component to limit the magnetic sensitivity, and the zero-field resonance method was used to measure the spin relaxation rates of different alkali metal cells. Simultaneously, in a single-beam spin-exchange-relaxation-free (SERF) magnetometer, we demonstrated that the fundamental magnetic field sensitivity was also limited by the pumping light intensity. Based on our theoretical analysis and experimental results, we determined the optimal pumping light intensity and optimal gas pressure. We experimentally demonstrated that the magnetic field sensitivity was 8.89 fT / Hz in the single-beam configuration, with an active measurement volume of 3 × 3 × 3~mm3.
A new magnetometer with Cs vapor in the spin exchange relaxation free(SERF) regime is described.Cs has a higher saturated vapor pressure than other alkali metals;so cesium SERF magnetometer is particularly attractive in applications that require lower power dissipation.Four factors affect atomic transverse relaxations in the SERF magnetometer,including collisions and diffusions among Cs,N2 and He,laser pumping and detecting processes;the buffer gas pressure of He that affects the relaxation is calculated and discussed emphatically in theory at 105 ℃,the result shows that the optimum buffer gas pressure is 350×133.3 Pa.Under the optimum pressure,the polarized spectrum linewidth as the function of the cell temperature is discussed briefly.It is found the least linewidth is only 3.7 Hz corresponding to the electric spin relaxation rate of 278 s-1 at 105 ℃.The result provides a help to increase the sensitivity of the magnetometer with Cs vapor.
The microfabrication of cesium vapor cells for optically pumped magnetometry relies on optimization of buffer gas pressure in order to maximize atomic coherence time and sensitivity to external magnetic signals. We demonstrate post-bond nitrogen buffer gas pressure tuning through localized heating of an integrated micropill dispenser. We characterize the variation in the intrinsic longitudinal relaxation rate, γ 10 , and magnetic sensitivity, as a function of the resulting nitrogen buffer gas pressure. Measurements are conducted by employing an optically pumped magnetometer operating in a free-induction-decay configuration. γ 10 is extracted across a range of nitrogen pressures between 60 and 700 torr, measuring a minimum of 140 Hz at 115 torr. In addition, we achieve sensitivities as low as 130 fT / Hz at a bias field amplitude of about 50 μ T . With the optimal nitrogen buffer gas pressure now quantified and achievable post-fabrication, these mass-producible cells can be tailored to suit a variety of sensing applications, ensuring peak magnetometer performance. Published by the American Physical Society 2024
Alkali metal vapor cells are fundamental components in quantum sensors, and their relaxation characteristics critically influence both sensitivity and system stability. In Spin-Exchange Relaxation-Free (SERF) atomic magnetometers, although spin-exchange collisions are effectively suppressed, wall-collision-induced relaxation remains the primary limiting factor. A coating-enabled buffer-gas-free vapor cell (CBF-VC) is proposed as a novel sensor unit, realized through multilayer octadecyltrichlorosilane (OTS) selfassembled molecular coatings. The CBF-VC is integrated into a single-beam SERF atomic magnetometer, and experimental validation is conducted. The results indicate a significant extension of the wall collision relaxation time from 40.19 ms. This extended relaxation time directly enhances the magnetometer sensitivity by 48%, confirming the feasibility of CBF-VCs as a measurement-oriented vapor cell architecture. The findings demonstrate not only the effectiveness of anti-relaxation coatings, but also a new instrumentation pathway for advancing next-generation quantum sensing.
Nowadays, quantum sensor research is a very interesting and popular topic. High-sensitivity magnetic field measurements using quantum sensors have evolved into the most sensitive magnetic field sensor category today with the invention of atomic magnetometers operating in the spin-exchange relaxation-free (SERF) regime. This letter was prepared to investigate the magnetic field sensitivity changes depending on the buffer gas, temperature, and laser intensity using indigenously produced atomic vapor cells. In addition, the aim was to determine the optimum operating conditions of the atomic magnetometer operating in the SERF regime. As a result, the resonance linewidth and signal-to-noise ratio were measured, and the minimum detectable magnetic field was calculated. According to the obtained results, the lowest magnetic field for Cells I–III was measured as 5.12, 4.21, and 4.81 pT, respectively. The lowest magnetic field of all conditions was obtained in vapor cell (Cell-II) at 100 °C with 5 mW laser intensity. As a result, it has been experimentally proven that under the same conditions, increasing the buffer gas pressure in vapor cells can narrow the resonance linewidth, and the magnetic field sensitivity can be improved by increasing the laser intensity applied to the vapor cells.