We have demonstrated a new technique for detecting ultracold atoms. A balanced detection technique was used to reduce laser-induced detection noise in conjunction with modulation-transfer spectroscopy to distinguish cold atoms from a thermal cloud. Using this technique, we have achieved signal-to-noise ratios in excess of 2000:1.
We have demonstrated a new technique for fluorescence detection of ultracold atoms. Fluorescence from two spatially separated clouds of ultracold atoms illuminated by a mutual probe laser was imaged onto opposite quadrants of a position-sensitive detector. The populations in the two separated atomic clouds were measured by integrating the quadrant detector photocurrents. Simultaneous detection of the populations of the two atomic clouds was used to reduce noise caused by fluctuations in detection laser amplitude and frequency. Using this technique we observed quantum projection noise limited detection signal-to-noise ratios exceeding 2000:1. To demonstrate the application of our highly Sensitive detection we compared two atomic clocks with interrogation times of only 80 ms to obtain a relative frequency stability of 1x 10(exp -13) Tau (exp -1/2) where TAU is the integration time in seconds.
Resonant frequency modulation spectroscopy has been previously used as a highly sensitive method for measuring the output of cold atom interferometers. Using a detailed model that accounts for optical saturation, laser intensities and atomic densities that vary spatially, and radiation pressure on the atoms, we theoretically investigate under what parameter regimes the optimum signal-to-noise ratio is found under experimentally realistic conditions. We compare this technique to the standard method of fluorescence imaging and find that it outperforms fluorescence imaging for compact interferometers using condensed atomic sources or where the photon collection efficiency is limited. However, we find that fluorescence imaging is likely to be the preferred method when using squeezed atomic sources due to limited atom number.
All optical techniques used to probe the properties of Bose-Einstein condensates have been based on dispersion and absorption that can be described by a two-level atom. Both phenomena lead to spontaneous emission that is destructive at the low energies involved with ultracold atomic systems. Recently, both were shown to lead to the same limit to the signal to noise ratio for a given destruction. We develop a new method for calculating the phase shift of a laser beam and show that no single-pass optical technique using classical light and a three-level atom can exceed this limit. This puts significant restrictions on potential nondestructive measurement schemes.
The sharpening of atomic energy levels with decreasing temperature is the motivation for using atoms cooled to just a fraction above absolute zero as the detection medium for metrological applications. Ultracold atom “fountains” already have been used in atomic clocks and in gravimeters and gravity gradiometers. However, the cooling process provides a thermal cloud of warmer atoms that surround the cold-atom core, and as detection of the atoms usually relies on monitoring fluorescence or absorption transitions between energy levels, these thermal atoms broaden the spectra and reduce sensitivity.