Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Letters

Low-noise simultaneous fluorescence detection of two atomic states

Grant W. Biedermann, Xiaojing Wu, Louis Deslauriers, Ken Takase, Mark A. Kasevich

Published Jan 29, 2009• 55 citations
Publisher

Abstract

We demonstrate a new simultaneous normalized detection technique for fluorescence detection of ultracold atoms in a superposition of ground-state hyperfine levels. Using this technique we observe atom shot-noise limited detection signal-to-noise ratios in excess of 7800:1 per shot and 14400:1 in 1 s.
DOI
10.1364/ol.34.000347

Related papers

Low Noise Simultaneous Fluorescence Detection of Two Atomic States (PREPRINT)

M. Cashen, Fixler, J. B., Grant W. Biedermann +1 more

We have demonstrated a new technique for fluorescence detection of ultracold atoms. Fluorescence from two spatially separated clouds of ultracold atoms illuminated by a mutual probe laser was imaged onto opposite quadrants of a position-sensitive detector. The populations in the two separated atomic clouds were measured by integrating the quadrant detector photocurrents. Simultaneous detection of the populations of the two atomic clouds was used to reduce noise caused by fluctuations in detection laser amplitude and frequency. Using this technique we observed quantum projection noise limited detection signal-to-noise ratios exceeding 2000:1. To demonstrate the application of our highly Sensitive detection we compared two atomic clocks with interrogation times of only 80 ms to obtain a relative frequency stability of 1x 10(exp -13) Tau (exp -1/2) where TAU is the integration time in seconds.

•Apr 5, 2006•0 citations

Low-noise detection of ultracold atoms

J. M. McGuirk, G. T. Foster, J. B. Fixler +1 more

We have demonstrated a new technique for detecting ultracold atoms. A balanced detection technique was used to reduce laser-induced detection noise in conjunction with modulation-transfer spectroscopy to distinguish cold atoms from a thermal cloud. Using this technique, we have achieved signal-to-noise ratios in excess of 2000:1.

Optics Letters•Mar 15, 2001•30 citations

Fluorescence detection at the atom shot noise limit for atom interferometry

E Rocco, R N Palmer, T. Valenzuela +3 more

Atom interferometers (AIs) are promising tools for precision measurement with applications ranging from geophysical exploration and tests of the equivalence principle of general relativity to the detection of gravitational waves. Their optimal sensitivity is ultimately limited by their detection noise. We review resonant and near-resonant methods to detect the atom number of the interferometer outputs, and we theoretically analyze the relative influence of various scheme dependent noise sources and the technical challenges affecting the detection. We show that for the typical conditions under which an AI operates, simultaneous fluorescence detection with a charge-coupled device sensor is the optimal imaging scheme. We extract the laser beam parameters such as detuning, intensity, and duration required for reaching the atom shot noise limit.

arXiv:1404.7117•New Journal of Physics•Sep 25, 2014•49 citations

Sub-atom shot noise Faraday imaging of ultracold atom clouds

M A Kristensen, Miroslav Gajdacz, P L Pedersen +4 more

We demonstrate that a dispersive imaging technique based on the Faraday effect can measure the atom number in a large, ultracold atom cloud with a precision below the atom shot noise level. The minimally destructive character of the technique allows us to take multiple images of the same cloud, which enables sub-atom shot noise measurement precision of the atom number and allows for an in situ determination of the measurement precision. We have developed a noise model that quantitatively describes the noise contributions due to photon shot noise in the detected light and the noise associated with single atom loss. This model contains no free parameters and is calculated through an analysis of the fluctuations in the acquired images. For clouds containing N ∼ 5 × 10 6 atoms, we achieve a precision more than a factor of two below the atom shot noise level.

arXiv:1608.06814•Journal of Physics B Atomic Molecular and Optical Physics•Jan 17, 2017•33 citations

原子干涉仪的竖直荧光探测方案

戴怡瑾 Dai Yijin, 王春唯 Wang Chunwei, 李鑫 Li Xin +4 more

Objective In recent years, with advancements in cold atom physics and relevant experimental techniques, cold atom interferometry has emerged as an important tool, finding widespread applications in precision measurements and fundamental physics research. Research on high-precision and portable atomic interferometers has become very popular. In precision measurement experiments, the system miniaturization requires the downsizing of the vacuum chamber. A vertical fluorescence scheme for different atomic ground states can cancel the additional detection zones in traditional parallel detection schemes and achieve miniaturization of the vacuum chamber for the interferometers. This detection scheme is based on the sequence detection of atoms in distinctive states, where the atoms absorb energy from the detection beams, resulting in atomic temperature increase and subsequently detection efficiency decrease. Otherwise, the detection noise and the signal-to-noise ratio (SNR) should be evaluated to improve measurement precision. We hope that our scheme can optimize SNR and reduce the main detection noise. Methods Our study is based on sequence fluorescence detection, and the noise sources include the shot noise, the circuit noise, the intensity, and the frequency noise of the detection beams. Compared to traditional parallel detection schemes, the vertical detection scheme is greatly affected by shot noise. In this scheme, the atoms in the F=2 state and the total atoms are detected sequentially. The proportion of F=2 atoms in the total number of atoms is employed to represent the signal. This method is called normalized detection, whose application can reduce the shot noise in the signal. Furthermore, based on theoretical analysis, adjusting various parameters of the detection beams can minimize the detection shot noise, thereby optimizing SNR. Specifically, the atoms absorb energy from the detection beams, causing atomic temperature increase and subsequently detection efficiency degradation. Additionally, due to the presence of detuning in the detection beams, the sequence detection may result in the occurrence of non-closed transitions, which enhances the shot noise during the detection process. Our study evaluates the influence of detection beam frequency and duration. Results and Discussions The scan of the detection frequency after the first detection pulse is applied is shown in Fig. 2. With the detection time extended to 0.5 ms, the resonance spectrum obtained from the scan splits from a Gaussian-type resonance peak into two distinct peaks. An additional sideband can be observed as the vertically polarized vertical detection beams interact with the atoms, forming 1D molasses. Additionally, the resonance frequency shifts approximately 2 MHz compared to the resonance frequency during 0.5 ms detection duration. This requires shortening the duration of the detection beams to optimize the signal. On the other side, for the detection process, the fluctuation in the number of atoms falling into the dark state is also a major shot noise source. The influence of such fluctuations on the SNR can be assessed by theoretical calculations. When the detection duration is longer than the minimum detection duration, an optimized SNR is achieved. In the experiment, the standard deviation of detection is measured, and an optimal range of detection duration exists. Additionally, conducting detection within this range can achieve optimized detection results. Conclusions Generally, we provide a basic framework for a vertical detection scheme, utilizing fluorescence detection with detection beams in the vertical direction. Traditional detection schemes require two horizontal probe beams, necessitating additional areas and windows within the vacuum chamber for state detection of atoms, which is not conducive to the miniaturization of the atomic interferometer system as a whole. By adopting this vertical scheme, we successfully reduce the volume of the vacuum chamber and eliminate the extra detection areas provided by traditional horizontal detection schemes. We optimize the detection sequence, shorten the detection time, and achieve a normalized standard deviation of 0.014. Furthermore, our study measures the ratio of atoms participating in the cyclic transition in the experiment, and the SNR calculation helps us estimate the noise caused by non-closed transitions during the detection. Under the application of sequential detection in the experiment, fluctuations in the SNR are observed when the laser intensity, frequency, and duration change due to the loss caused by atoms participating in non-closed transitions. In this case, the optimal combination of the atomic cycling rate and detection time obtained via analysis reduces shot noise and optimizes the measurement precision. Additionally, eliminating extra noise such as circuit noise and noise caused by changes in the intensity and frequency of the probe beams can enhance the SNR. In future work, we will focus on further improving this detection scheme and exploring its applications in advanced cold atom experiments.

Acta Optica Sinica•Jan 1, 2025•1 citation

Number-resolved preparation of mesoscopic atomic ensembles

Andreas Hüper, Cebrail Pür, M Hetzel +7 more

The analysis of entangled atomic ensembles and their application for interferometry beyond the standard quantum limit requires an accurate determination of the number of atoms. We present an accurate fluorescence detection technique for atoms that is fully integrated into an experimental apparatus for the production of many-particle entangled quantum states. Number-resolved fluorescence measurements with single-atom accuracy for 1 up to 30 atoms are presented. According to our noise analysis, we extrapolate that the single-atom accuracy extends to a limiting atom number of 390(20) atoms. We utilize the accurate atom number detection for a number stabilization of the laser-cooled atomic ensemble. For a target ensemble size of 7 atoms prepared on demand, we achieve a 92(2)% preparation fidelity and reach number fluctuations 18(1) dB below the shot noise level using real-time feedback on the magneto-optical trap.

arXiv:1912.05689•New Journal of Physics•Nov 1, 2021•13 citations
We have demonstrated a new technique for fluorescence detection of ultracold atoms. Fluorescence from two spatially separated clouds of ultracold atoms illuminated by a mutual probe laser was imaged onto opposite quadrants of a position-sensitive detector. The populations in the two separated atomic clouds were measured by integrating the quadrant detector photocurrents. Simultaneous detection of the populations of the two atomic clouds was used to reduce noise caused by fluctuations in detection laser amplitude and frequency. Using this technique we observed quantum projection noise limited detection signal-to-noise ratios exceeding 2000:1. To demonstrate the application of our highly Sensitive detection we compared two atomic clocks with interrogation times of only 80 ms to obtain a relative frequency stability of 1x 10(exp -13) Tau (exp -1/2) where TAU is the integration time in seconds.
Atom interferometers (AIs) are promising tools for precision measurement with applications ranging from geophysical exploration and tests of the equivalence principle of general relativity to the detection of gravitational waves. Their optimal sensitivity is ultimately limited by their detection noise. We review resonant and near-resonant methods to detect the atom number of the interferometer outputs, and we theoretically analyze the relative influence of various scheme dependent noise sources and the technical challenges affecting the detection. We show that for the typical conditions under which an AI operates, simultaneous fluorescence detection with a charge-coupled device sensor is the optimal imaging scheme. We extract the laser beam parameters such as detuning, intensity, and duration required for reaching the atom shot noise limit.
We demonstrate that a dispersive imaging technique based on the Faraday effect can measure the atom number in a large, ultracold atom cloud with a precision below the atom shot noise level. The minimally destructive character of the technique allows us to take multiple images of the same cloud, which enables sub-atom shot noise measurement precision of the atom number and allows for an in situ determination of the measurement precision. We have developed a noise model that quantitatively describes the noise contributions due to photon shot noise in the detected light and the noise associated with single atom loss. This model contains no free parameters and is calculated through an analysis of the fluctuations in the acquired images. For clouds containing N ∼ 5 × 10 6 atoms, we achieve a precision more than a factor of two below the atom shot noise level.
Objective In recent years, with advancements in cold atom physics and relevant experimental techniques, cold atom interferometry has emerged as an important tool, finding widespread applications in precision measurements and fundamental physics research. Research on high-precision and portable atomic interferometers has become very popular. In precision measurement experiments, the system miniaturization requires the downsizing of the vacuum chamber. A vertical fluorescence scheme for different atomic ground states can cancel the additional detection zones in traditional parallel detection schemes and achieve miniaturization of the vacuum chamber for the interferometers. This detection scheme is based on the sequence detection of atoms in distinctive states, where the atoms absorb energy from the detection beams, resulting in atomic temperature increase and subsequently detection efficiency decrease. Otherwise, the detection noise and the signal-to-noise ratio (SNR) should be evaluated to improve measurement precision. We hope that our scheme can optimize SNR and reduce the main detection noise. Methods Our study is based on sequence fluorescence detection, and the noise sources include the shot noise, the circuit noise, the intensity, and the frequency noise of the detection beams. Compared to traditional parallel detection schemes, the vertical detection scheme is greatly affected by shot noise. In this scheme, the atoms in the F=2 state and the total atoms are detected sequentially. The proportion of F=2 atoms in the total number of atoms is employed to represent the signal. This method is called normalized detection, whose application can reduce the shot noise in the signal. Furthermore, based on theoretical analysis, adjusting various parameters of the detection beams can minimize the detection shot noise, thereby optimizing SNR. Specifically, the atoms absorb energy from the detection beams, causing atomic temperature increase and subsequently detection efficiency degradation. Additionally, due to the presence of detuning in the detection beams, the sequence detection may result in the occurrence of non-closed transitions, which enhances the shot noise during the detection process. Our study evaluates the influence of detection beam frequency and duration. Results and Discussions The scan of the detection frequency after the first detection pulse is applied is shown in Fig. 2. With the detection time extended to 0.5 ms, the resonance spectrum obtained from the scan splits from a Gaussian-type resonance peak into two distinct peaks. An additional sideband can be observed as the vertically polarized vertical detection beams interact with the atoms, forming 1D molasses. Additionally, the resonance frequency shifts approximately 2 MHz compared to the resonance frequency during 0.5 ms detection duration. This requires shortening the duration of the detection beams to optimize the signal. On the other side, for the detection process, the fluctuation in the number of atoms falling into the dark state is also a major shot noise source. The influence of such fluctuations on the SNR can be assessed by theoretical calculations. When the detection duration is longer than the minimum detection duration, an optimized SNR is achieved. In the experiment, the standard deviation of detection is measured, and an optimal range of detection duration exists. Additionally, conducting detection within this range can achieve optimized detection results. Conclusions Generally, we provide a basic framework for a vertical detection scheme, utilizing fluorescence detection with detection beams in the vertical direction. Traditional detection schemes require two horizontal probe beams, necessitating additional areas and windows within the vacuum chamber for state detection of atoms, which is not conducive to the miniaturization of the atomic interferometer system as a whole. By adopting this vertical scheme, we successfully reduce the volume of the vacuum chamber and eliminate the extra detection areas provided by traditional horizontal detection schemes. We optimize the detection sequence, shorten the detection time, and achieve a normalized standard deviation of 0.014. Furthermore, our study measures the ratio of atoms participating in the cyclic transition in the experiment, and the SNR calculation helps us estimate the noise caused by non-closed transitions during the detection. Under the application of sequential detection in the experiment, fluctuations in the SNR are observed when the laser intensity, frequency, and duration change due to the loss caused by atoms participating in non-closed transitions. In this case, the optimal combination of the atomic cycling rate and detection time obtained via analysis reduces shot noise and optimizes the measurement precision. Additionally, eliminating extra noise such as circuit noise and noise caused by changes in the intensity and frequency of the probe beams can enhance the SNR. In future work, we will focus on further improving this detection scheme and exploring its applications in advanced cold atom experiments.
The analysis of entangled atomic ensembles and their application for interferometry beyond the standard quantum limit requires an accurate determination of the number of atoms. We present an accurate fluorescence detection technique for atoms that is fully integrated into an experimental apparatus for the production of many-particle entangled quantum states. Number-resolved fluorescence measurements with single-atom accuracy for 1 up to 30 atoms are presented. According to our noise analysis, we extrapolate that the single-atom accuracy extends to a limiting atom number of 390(20) atoms. We utilize the accurate atom number detection for a number stabilization of the laser-cooled atomic ensemble. For a target ensemble size of 7 atoms prepared on demand, we achieve a 92(2)% preparation fidelity and reach number fluctuations 18(1) dB below the shot noise level using real-time feedback on the magneto-optical trap.