Applied Physics Letters

Two-stage amplifier based on a double relaxation oscillation superconducting quantum interference device

M. Podt, Michiel J. van Duuren, A.W. Hamster, J. Flokstra, Horst Rogalla

Published Oct 11, 1999• 25 citations
Publisher

Abstract

A low-noise single-chip two-stage superconducting quantum interference device (SQUID) system with a double relaxation oscillation SQUID as the second stage has been realized. The system was operated in a direct voltage readout mode, with a closed loop bandwidth up to 1 MHz. Operated at 4.2 K, the white flux noise measured in flux locked loop was 1.3 μΦ0/√Hz, corresponding to an energy sensitivity of ε≈27h. Owing to the large flux-to-voltage transfer of up to 3.6 mV/Φ0, the room-temperature preamplifier noise did not dominate the overall flux noise.

DOI
10.1063/1.125001

Related papers

Low-noise SQUIDs with large transfer - two stage SQUIDs based on DROSs

M. Podt, Jakob Flokstra, Horst Rogalla

We have realized a two-stage integrated superconducting quantum interference device (SQUID) system with a closed loop bandwidth of 2.5 MHz, operated in a direct voltage readout mode. The corresponding flux slew rate was 1.3×105 Φ0/s and the measured white flux noise was 1.3 μΦ0/√Hz at 4.2 K. The system is based on a conventional dc SQUID with a double relaxation oscillation SQUID (DROS) as the second stage. Because of the large flux-to-voltage transfer, the sensitivity of the system is completely determined by the sensor SQUID and not by the DROS or the room-temperature preamplifier. Decreasing the Josephson junction area enables a further improvement of the sensitivity of the two-stage SQUID systems.

•Aug 26, 2001•0 citations

Dynamic performance of single-stage SQUID current amplifier with varying device parameters

Jin‐Mok Kim, Yong‐Ho Lee, Hyukchan Kwon +1 more

We have fabricated a single-stage superconducting quantum interference device (SQUID) current amplifier for detecting pulse outputs of a superconducting microcalorimeter. The current amplifier is made of a double relaxation oscillation SQUID (DROS) that provides a high flux-to-voltage transfer of about 1mV//spl Phi//sub 0/ and a large modulation depth of 80 /spl mu/V. Due to the high flux-to-voltage transfer, the voltage output of the DROS is measured directly with a room-temperature dc preamplifier. The bandwidth of the current amplifier is measured to be 1.2 MHz. Typical noise of the DROS current amplifier is about 6 pA//spl radic/Hz.

IEEE Transactions on Applied Superconductivity•Jun 1, 2003•0 citations

High sensitivity double relaxation oscillation superconducting quantum interference devices

Derk Jan Adelerhof, Jun Kawai, Gen Uehara +1 more

Double relaxation oscillation superconducting quantum interference devices (SQUIDs) (DROSs) have been fabricated with estimated relaxation frequencies up to 14 GHz. Both the intrinsic flux noise and the performance in a flux locked loop with direct voltage readout have been studied. In flux locked loop, a noise level of 0.55 μφ0/√Hz corresponding to an energy sensitivity of 34 h has been obtained for a DROS with a SQUID inductance of 29 pH. The intrinsic sensitivity improves with increasing relaxation frequency, leveling off to a value of 13 h at relaxation frequencies higher than about 3 GHz.

Applied Physics Letters•Nov 14, 1994•22 citations

Low-noise ultra-high-speed dc SQUID readout electronics

D. Drung, Colmar Hinnrichs, H.-J. Barthelmess

User-friendly ultra-high-speed readout electronics for dc superconducting quantum interference devices (SQUIDs) are presented. To maximize the system bandwidth, the SQUID is directly read out without flux modulation. A composite preamplifier is used consisting of a slow dc amplifier in parallel with a fast ac amplifier. In this way, excellent dc precision and a high amplifier bandwidth of 50 MHz are achieved, simultaneously. A virtual 50 Ω amplifier input resistance with negligible excess noise is realized by active shunting, i.e., by applying feedback from preamplifier output to input via a high resistance. The white voltage and current noise levels are 0.33 nV Hz −1 and 2.6 pA Hz −1/2 , respectively. The electronics is fully computer controlled via a microcontroller integrated into the flux-locked loop (FLL) board. Easy-to-use software makes the various electronic settings accessible. A wide bias voltage range of 1.3 mV enables the readout of series SQUID arrays. Furthermore, additional current sources allow the operation of two-stage SQUIDs or transition edge sensors. The electronics was tested using various SQUIDs with input inductances between 30 nH and 1.5 µH. Typically, the maximum FLL bandwidth was 20 MHz, which is close to the theoretical limit given by transmission line delay within the FLL. Slew rates of up to 4.6 Φ 0 µs −1 were achieved with series SQUID arrays. Current noise levels as low as 0.47 pA Hz −1/2 and coupled energy sensitivities between 90 h and 500 h were measured at 4.2 K, where h is the Planck constant. The noise did not degrade when the system bandwidth was increased to the maximum value of about 20 MHz. With a two-stage set-up, intrinsic white energy sensitivities of 30 h and 2.3 h were measured at 4.2 and 0.3 K, respectively.

Superconductor Science and Technology•Feb 27, 2006•72 citations

Double relaxation oscillation superconducting quantum interference devices with gradiometric layout

Michiel J. van Duuren, G.C.S. Brons, Derk Jan Adelerhof +2 more

Double relaxation oscillation superconducting quantum interference devices (DROSs) with a gradiometric signal SQUID and either a reference SQUID or a reference junction will be presented in this article. The devices are user friendly, particularly those with a reference junction. Because of the large flux-to-voltage transfer of ∂V/∂Φ=0.7–1 mV/Φ0, the devices can be operated in a flux locked loop based on direct voltage readout without loss of sensitivity. The typical white flux noise of the DROSs amounts to √SΦ=5–6μΦ0/√Hz, which corresponds to an energy resolution ε=SΦ/2Lsq≃200 h. Coupled to an external planar first-order gradiometer, a white magnetic field sensitivity of √SB<2 fT/√Hz was measured inside a magnetically shielded room.

Journal of Applied Physics•Oct 1, 1997•12 citations

Double dc SQUID for flux-locked-loop operation

Vittorio Foglietti

A novel double dc superconducting quantum interference device (SQUID) is proposed. It consists of two SQUIDs with different geometries in cascade configuration. The structure makes the device particularly suitable for flux-locked-loop operation without need of a room-temperature heterodyne modulation circuitry and a matching network between the SQUID and the preamplifier, thus simplifying the readout electronic system. The noise performance is calculated as a function of the electrical parameters of the device. The noise contribution of the room-temperature preamplifier can be made negligible using <m1;&2p>appropriate SQUID parameters while the slew rate of the system can approach 106Φ0/s.

Applied Physics Letters•Jul 22, 1991•29 citations
A low-noise single-chip two-stage superconducting quantum interference device (SQUID) system with a double relaxation oscillation SQUID as the second stage has been realized. The system was operated in a direct voltage readout mode, with a closed loop bandwidth up to 1 MHz. Operated at 4.2 K, the white flux noise measured in flux locked loop was 1.3 μΦ0/√Hz, corresponding to an energy sensitivity of ε≈27h. Owing to the large flux-to-voltage transfer of up to 3.6 mV/Φ0, the room-temperature preamplifier noise did not dominate the overall flux noise.
We have realized a two-stage integrated superconducting quantum interference device (SQUID) system with a closed loop bandwidth of 2.5 MHz, operated in a direct voltage readout mode. The corresponding flux slew rate was 1.3×105 Φ0/s and the measured white flux noise was 1.3 μΦ0/√Hz at 4.2 K. The system is based on a conventional dc SQUID with a double relaxation oscillation SQUID (DROS) as the second stage. Because of the large flux-to-voltage transfer, the sensitivity of the system is completely determined by the sensor SQUID and not by the DROS or the room-temperature preamplifier. Decreasing the Josephson junction area enables a further improvement of the sensitivity of the two-stage SQUID systems.
We have fabricated a single-stage superconducting quantum interference device (SQUID) current amplifier for detecting pulse outputs of a superconducting microcalorimeter. The current amplifier is made of a double relaxation oscillation SQUID (DROS) that provides a high flux-to-voltage transfer of about 1mV//spl Phi//sub 0/ and a large modulation depth of 80 /spl mu/V. Due to the high flux-to-voltage transfer, the voltage output of the DROS is measured directly with a room-temperature dc preamplifier. The bandwidth of the current amplifier is measured to be 1.2 MHz. Typical noise of the DROS current amplifier is about 6 pA//spl radic/Hz.
Double relaxation oscillation superconducting quantum interference devices (SQUIDs) (DROSs) have been fabricated with estimated relaxation frequencies up to 14 GHz. Both the intrinsic flux noise and the performance in a flux locked loop with direct voltage readout have been studied. In flux locked loop, a noise level of 0.55 μφ0/√Hz corresponding to an energy sensitivity of 34 h has been obtained for a DROS with a SQUID inductance of 29 pH. The intrinsic sensitivity improves with increasing relaxation frequency, leveling off to a value of 13 h at relaxation frequencies higher than about 3 GHz.
User-friendly ultra-high-speed readout electronics for dc superconducting quantum interference devices (SQUIDs) are presented. To maximize the system bandwidth, the SQUID is directly read out without flux modulation. A composite preamplifier is used consisting of a slow dc amplifier in parallel with a fast ac amplifier. In this way, excellent dc precision and a high amplifier bandwidth of 50 MHz are achieved, simultaneously. A virtual 50 Ω amplifier input resistance with negligible excess noise is realized by active shunting, i.e., by applying feedback from preamplifier output to input via a high resistance. The white voltage and current noise levels are 0.33 nV Hz −1 and 2.6 pA Hz −1/2 , respectively. The electronics is fully computer controlled via a microcontroller integrated into the flux-locked loop (FLL) board. Easy-to-use software makes the various electronic settings accessible. A wide bias voltage range of 1.3 mV enables the readout of series SQUID arrays. Furthermore, additional current sources allow the operation of two-stage SQUIDs or transition edge sensors. The electronics was tested using various SQUIDs with input inductances between 30 nH and 1.5 µH. Typically, the maximum FLL bandwidth was 20 MHz, which is close to the theoretical limit given by transmission line delay within the FLL. Slew rates of up to 4.6 Φ 0 µs −1 were achieved with series SQUID arrays. Current noise levels as low as 0.47 pA Hz −1/2 and coupled energy sensitivities between 90 h and 500 h were measured at 4.2 K, where h is the Planck constant. The noise did not degrade when the system bandwidth was increased to the maximum value of about 20 MHz. With a two-stage set-up, intrinsic white energy sensitivities of 30 h and 2.3 h were measured at 4.2 and 0.3 K, respectively.
Double relaxation oscillation superconducting quantum interference devices (DROSs) with a gradiometric signal SQUID and either a reference SQUID or a reference junction will be presented in this article. The devices are user friendly, particularly those with a reference junction. Because of the large flux-to-voltage transfer of ∂V/∂Φ=0.7–1 mV/Φ0, the devices can be operated in a flux locked loop based on direct voltage readout without loss of sensitivity. The typical white flux noise of the DROSs amounts to √SΦ=5–6μΦ0/√Hz, which corresponds to an energy resolution ε=SΦ/2Lsq≃200 h. Coupled to an external planar first-order gradiometer, a white magnetic field sensitivity of √SB<2 fT/√Hz was measured inside a magnetically shielded room.
A novel double dc superconducting quantum interference device (SQUID) is proposed. It consists of two SQUIDs with different geometries in cascade configuration. The structure makes the device particularly suitable for flux-locked-loop operation without need of a room-temperature heterodyne modulation circuitry and a matching network between the SQUID and the preamplifier, thus simplifying the readout electronic system. The noise performance is calculated as a function of the electrical parameters of the device. The noise contribution of the room-temperature preamplifier can be made negligible using <m1;&2p>appropriate SQUID parameters while the slew rate of the system can approach 106Φ0/s.