Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Express

High-order temporal coherences of chaotic and laser light

Martin J. Stevens, Burm Baek, Eric A. Dauler, Andrew J. Kerman, R. J. Molnar, Scott A. Hamilton, Karl K. Berggren, Richard P. Mirin, Sae Woo Nam

Published Jan 12, 2010• 68 citations
Publisher

Abstract

We demonstrate a new approach to measuring high-order temporal coherences that uses a four-element superconducting nanowire single-photon detector. The four independent, interleaved single-photon-sensitive elements parse a single spatial mode of an optical beam over dimensions smaller than the minimum diffraction-limited spot size. Integrating this device with four-channel time-tagging electronics to generate multi-start, multi-stop histograms enables measurement of temporal coherences up to fourth order for a continuous range of all associated time delays. We observe high-order photon bunching from a chaotic, pseudo-thermal light source, measuring maximum third- and fourth-order coherence values of 5.87 +/- 0.17 and 23.1 +/- 1.8, respectively, in agreement with the theoretically predicted values of 3! = 6 and 4! = 24. Laser light, by contrast, is confirmed to have coherence values of approximately 1 for second, third and fourth orders at all time delays.

DOI
10.1364/oe.18.001430

Related papers

High-order photon correlations through double Hanbury Brown–Twiss measurements

Yanqiang Guo, Lijing Wang, Yu Wang +4 more

Abstract We present an experimental technique that can accurately measure the high-order photon correlations of various light fields based on double Hanbury Brown–Twiss scheme. The system consists of four conventional binary response single-photon counting modules which are non-photon-number-resolving detectors. We theoretically analyze the effects of the experimental conditions on the high-order photon correlations of coherent, chaotic thermal, Fock and squeezed vacuum states with considering the overall efficiency and background noise. In experiment, we determine the proper resolution time from 2 9 = 512 ns to 2 11 = 2048 ns and counting rate from 10 kc s −1 to 100 kc s −1 for characterizing the exact second-, third- and fourth-order photon correlations of chaotic thermal state. At complete time delays, we also observe the third- and fourth-order photon correlations of chaotic thermal state, with the maximum high-order correlation values of 5.99 ± 0.02 and 23.9 ± 0.2 respectively, which are in good agreement with the theoretical values of 6 and 24. The demonstrated experimental technique with high accuracy is a promising tool for investigating quantum optical coherence and ghost imaging.

Journal of Optics•Jul 7, 2020•10 citations

Third-order correlation function and ghost imaging of chaotic thermal light in the photon counting regime

Yu Zhou, Jason Simon, Jianbin Liu +1 more

In a near-field three-photon correlation measurement, we observed the third-order temporal and spatial correlation functions of chaotic thermal light in the single-photon counting regime. In the study, we found that the probability of jointly detecting three randomly radiated photons from a chaotic thermal source by three individual detectors is $6$ times greater if the photodetection events fall in the coherence time and coherence area of the radiation field than if they do not. From the viewpoint of quantum mechanics, the observed phenomenon is the result of three-photon interference. By making use of this property, we measured the three-photon thermal light lensless ghost image of a double spot and achieved higher visibility compared with the two-photon thermal light ghost image.

Physical Review A•Apr 26, 2010•71 citations

Analysis and measurement of high-order photon correlations of light fields

Yanqiang Guo, Lijing Wang, Yu Wang +3 more

High-order photon correlations of light fields are important for characterizing the quantum nature. Since Hanbury Brown and Twiss conducted the pioneering experiments in the 1950s, the HBT effect has inspired extensive research on high-order photon correlation in quantum optics, quantum information, and quantum imaging. The Single-photon counting module is one of the most widely used single-photon detectors. Due to its high detection efficiency and low dark counts in the visible and near-infrared region, it is reasonably chosen for basic research on quantum mechanics. Many researches have demonstrated that the maximum value of second-order photon correlation g(2)(τ) at zero delay (τ = 0) can be used to distinguish different light fields. Therefore, the HBT scheme containing two single photon detectors have been widely used in many advanced studies, such as space interference, ghost imaging, single photon detection with high efficiency, etc. However, higher-order photon correlations g(n) (n > 2) can reveal more measurable characteristics of light fields, such as information about the non-Gaussian scattering process, the skewness and kurtosis of photon number distribution, etc. When the extended HBT scheme is used to measure higher-order photon correlations, the experimental conditions including quantum efficiency and background noise greatly affect the photon correlation measurement. The influences of the counting rate and resolution time of the detection system on the measurements are also very important and cannot be ignored. Therefore, the comprehensive considering of various influence factors is necessary for accurately measuring the high-order photon correlations and also a challenge. In this paper, we present a method based on double Hanbury Brown-Twiss scheme for the accurate measuring of high-order photon correlations g(n) (n > 2). The system consists of four single photon counting modules and is used to detect and analyze the joint distribution probability of temporal photon correlation. Considering the effects of the background noise and overall efficiency, theoretically, we analyze the correlations of the third- and fourth-order photon with the incident light intensity, squeezing parameter and photon number respectively for thermal state, coherent state, squeezed vacuum state, and Fock state. Meanwhile, experimentally we study the influences of resolution time and counting rate on correlations of the coherent state and thermal state with third- and fourth-order photon. On condition that the resolution time is 210 ns and the counting rate is 80 kc/s, the correlations of third and fourth-order photon with the thermal state at zero time delay are accurately measured, and the relative statistical deviations of the measured vales from the theoretical values are 0.3% and 0.8%, respectively. In addition, the third- and fourth-order photon correlations of the thermal state at different delay times are also observed. It is demonstrated that the high-order photon correlations of light fields are measured accurately by comprehensively analyzing various influencing factors. This technique provides a promising and useful tool to investigate quantum correlated imaging and quantum coherence of light fields.

Acta Physica Sinica•Jan 1, 2020•3 citations

Temporal correlation of photons following frequency up-conversion

Lijun Ma, Matthew T. Rakher, Martin J. Stevens +3 more

We demonstrate an approach to measure temporal correlations of photons in the near infrared range using frequency up-conversion. In this approach, the near infrared signal photons are converted into the visible range, in which highly efficient silicon avalanche photodiodes are used to perform the temporal correlation measurements. A coherent light source and a pseudo-thermal light source were used in the experiment. The results are in agreement with theoretical values and those obtained from measurements directly made using superconducting nanowire single photon detectors. We conclude that the temporal correlation (up to 4th order) of photons was preserved in the frequency up-conversion process. We further theoretically and experimentally studied the influence of the dark counts on the measurement. The setup uses commercially available components and achieves high total detection efficiency (~26%).

Optics Express•May 12, 2011•19 citations

Third- and fourth-order coherences measured with a multi-element superconducting nanowire single-photon detector | NIST

Martin J. Stevens, Burm Baek, Eric A. Dauler +6 more

•May 29, 2009•0 citations

Measuring intensity correlations with a two-element superconducting nanowire single-photon detector

Eric A. Dauler, Martin J. Stevens, Burm Baek +5 more

Second-order intensity correlation measurements were made using a two-element superconducting nanowire single photon detector (SNSPD) without the need for an optical beam splitter. This approach can be used to obtain a $50\text{\penalty1000-\hskip0pt}\mathrm{ps}$ full width at half maximum timing resolution over a wide range of visible and near-infrared wavelengths and can be extended to measure higher-order intensity correlations. Measurements of the second-order intensity correlation of a pulsed laser and an InGaAs quantum dot were made using both a two-element SNSPD and a conventional Hanbury Brown--Twiss interferometer to demonstrate the accuracy and advantages of the multielement SNSPD.

Physical Review A•Nov 24, 2008•19 citations
We demonstrate a new approach to measuring high-order temporal coherences that uses a four-element superconducting nanowire single-photon detector. The four independent, interleaved single-photon-sensitive elements parse a single spatial mode of an optical beam over dimensions smaller than the minimum diffraction-limited spot size. Integrating this device with four-channel time-tagging electronics to generate multi-start, multi-stop histograms enables measurement of temporal coherences up to fourth order for a continuous range of all associated time delays. We observe high-order photon bunching from a chaotic, pseudo-thermal light source, measuring maximum third- and fourth-order coherence values of 5.87 +/- 0.17 and 23.1 +/- 1.8, respectively, in agreement with the theoretically predicted values of 3! = 6 and 4! = 24. Laser light, by contrast, is confirmed to have coherence values of approximately 1 for second, third and fourth orders at all time delays.
Abstract We present an experimental technique that can accurately measure the high-order photon correlations of various light fields based on double Hanbury Brown–Twiss scheme. The system consists of four conventional binary response single-photon counting modules which are non-photon-number-resolving detectors. We theoretically analyze the effects of the experimental conditions on the high-order photon correlations of coherent, chaotic thermal, Fock and squeezed vacuum states with considering the overall efficiency and background noise. In experiment, we determine the proper resolution time from 2 9 = 512 ns to 2 11 = 2048 ns and counting rate from 10 kc s −1 to 100 kc s −1 for characterizing the exact second-, third- and fourth-order photon correlations of chaotic thermal state. At complete time delays, we also observe the third- and fourth-order photon correlations of chaotic thermal state, with the maximum high-order correlation values of 5.99 ± 0.02 and 23.9 ± 0.2 respectively, which are in good agreement with the theoretical values of 6 and 24. The demonstrated experimental technique with high accuracy is a promising tool for investigating quantum optical coherence and ghost imaging.
In a near-field three-photon correlation measurement, we observed the third-order temporal and spatial correlation functions of chaotic thermal light in the single-photon counting regime. In the study, we found that the probability of jointly detecting three randomly radiated photons from a chaotic thermal source by three individual detectors is 666 times greater if the photodetection events fall in the coherence time and coherence area of the radiation field than if they do not. From the viewpoint of quantum mechanics, the observed phenomenon is the result of three-photon interference. By making use of this property, we measured the three-photon thermal light lensless ghost image of a double spot and achieved higher visibility compared with the two-photon thermal light ghost image.
High-order photon correlations of light fields are important for characterizing the quantum nature. Since Hanbury Brown and Twiss conducted the pioneering experiments in the 1950s, the HBT effect has inspired extensive research on high-order photon correlation in quantum optics, quantum information, and quantum imaging. The Single-photon counting module is one of the most widely used single-photon detectors. Due to its high detection efficiency and low dark counts in the visible and near-infrared region, it is reasonably chosen for basic research on quantum mechanics. Many researches have demonstrated that the maximum value of second-order photon correlation g(2)(τ) at zero delay (τ = 0) can be used to distinguish different light fields. Therefore, the HBT scheme containing two single photon detectors have been widely used in many advanced studies, such as space interference, ghost imaging, single photon detection with high efficiency, etc. However, higher-order photon correlations g(n) (n > 2) can reveal more measurable characteristics of light fields, such as information about the non-Gaussian scattering process, the skewness and kurtosis of photon number distribution, etc. When the extended HBT scheme is used to measure higher-order photon correlations, the experimental conditions including quantum efficiency and background noise greatly affect the photon correlation measurement. The influences of the counting rate and resolution time of the detection system on the measurements are also very important and cannot be ignored. Therefore, the comprehensive considering of various influence factors is necessary for accurately measuring the high-order photon correlations and also a challenge. In this paper, we present a method based on double Hanbury Brown-Twiss scheme for the accurate measuring of high-order photon correlations g(n) (n > 2). The system consists of four single photon counting modules and is used to detect and analyze the joint distribution probability of temporal photon correlation. Considering the effects of the background noise and overall efficiency, theoretically, we analyze the correlations of the third- and fourth-order photon with the incident light intensity, squeezing parameter and photon number respectively for thermal state, coherent state, squeezed vacuum state, and Fock state. Meanwhile, experimentally we study the influences of resolution time and counting rate on correlations of the coherent state and thermal state with third- and fourth-order photon. On condition that the resolution time is 210 ns and the counting rate is 80 kc/s, the correlations of third and fourth-order photon with the thermal state at zero time delay are accurately measured, and the relative statistical deviations of the measured vales from the theoretical values are 0.3% and 0.8%, respectively. In addition, the third- and fourth-order photon correlations of the thermal state at different delay times are also observed. It is demonstrated that the high-order photon correlations of light fields are measured accurately by comprehensively analyzing various influencing factors. This technique provides a promising and useful tool to investigate quantum correlated imaging and quantum coherence of light fields.
We demonstrate an approach to measure temporal correlations of photons in the near infrared range using frequency up-conversion. In this approach, the near infrared signal photons are converted into the visible range, in which highly efficient silicon avalanche photodiodes are used to perform the temporal correlation measurements. A coherent light source and a pseudo-thermal light source were used in the experiment. The results are in agreement with theoretical values and those obtained from measurements directly made using superconducting nanowire single photon detectors. We conclude that the temporal correlation (up to 4th order) of photons was preserved in the frequency up-conversion process. We further theoretically and experimentally studied the influence of the dark counts on the measurement. The setup uses commercially available components and achieves high total detection efficiency (~26%).
Second-order intensity correlation measurements were made using a two-element superconducting nanowire single photon detector (SNSPD) without the need for an optical beam splitter. This approach can be used to obtain a $50\text{\penalty1000-\hskip0pt}\mathrm{ps}$ full width at half maximum timing resolution over a wide range of visible and near-infrared wavelengths and can be extended to measure higher-order intensity correlations. Measurements of the second-order intensity correlation of a pulsed laser and an InGaAs quantum dot were made using both a two-element SNSPD and a conventional Hanbury Brown--Twiss interferometer to demonstrate the accuracy and advantages of the multielement SNSPD.