Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Third-order correlation function and ghost imaging of chaotic thermal light in the photon counting regime

Yu Zhou, Jason Simon, Jianbin Liu, Yanhua H. Shih

Published Apr 26, 2010• 71 citations
Publisher

Abstract

In a near-field three-photon correlation measurement, we observed the third-order temporal and spatial correlation functions of chaotic thermal light in the single-photon counting regime. In the study, we found that the probability of jointly detecting three randomly radiated photons from a chaotic thermal source by three individual detectors is $6$ times greater if the photodetection events fall in the coherence time and coherence area of the radiation field than if they do not. From the viewpoint of quantum mechanics, the observed phenomenon is the result of three-photon interference. By making use of this property, we measured the three-photon thermal light lensless ghost image of a double spot and achieved higher visibility compared with the two-photon thermal light ghost image.

DOI
10.1103/physreva.81.043831

Related papers

Third-order optical intensity correlation measurements of pseudo-thermal light

Xi-Hao Chen, Wei Tao Wu, Shao-Ying Meng +1 more

Third-order Hanbrury Brown—Twiss and double-slit interference experiments with a pseudo-thermal light are performed by recording intensities in single, double and triple optical paths, respectively. The experimental results verifies the theoretical prediction that the indispensable condition for achieving a interference pattern or ghost image in N th-order intensity correlation measurements is the synchronous detection of the same light field by each reference detector, no matter the intensities recorded in one, or two, or N optical paths. It is shown that, when the reference detectors are scanned in the opposite directions, the visibility and resolution of the third-order spatial correlation function of thermal light is much better than that scanned in the same direction, but it is no use for obtaining the N th-order interference pattern or ghost image in the thermal N th-order interference or ghost imaging.

Chinese Physics B•Sep 1, 2014•2 citations

Fourth-Order Spatial Correlation of Thermal Light

Feng Wen, Xun Zhang, Xinxin Xue +3 more

We investigate the fourth-order spatial correlation properties of pseudo-thermal light in the photon counting regime, and apply the Klyshko advanced-wave picture to describe the process of four-photon coincidence counting measurement. We deduce the theory of a proof-of-principle four-photon coincidence counting configuration, and find that if the four randomly radiated photons come from the same radiation area and are indistinguishable in principle, the fourth-order correlation of them is 24 times larger than that when four photons come from different radiation areas. In addition, we also show that the higher-order spatial correlation function can be decomposed into multiple lower-order correlation functions, and the contrast and visibility of low-order correlation peaks are less than those of higher orders, while the resolutions all are identical. This study may be useful for better understanding the four-photon interference and multi-channel correlation imaging.

Chinese Physics Letters•Nov 1, 2014•4 citations

Four-Photon Imaging with Thermal Light

Feng Wen, Xinxin Xue, Xun Zhang +4 more

In a near-field four-photon correlation measurement, ghost imaging with classical incoherent light is investigated. By applying the Klyshko advanced-wave picture, we consider the properties of four-photon spatial correlation and find that the fourth-order spatial correlation function can be decomposed into multiple lower-order correlation functions. On the basis of the spatial correlation properties, a proof-of-principle four-photon ghost imaging is proposed, and the effect of each part in a fourth-order correlation function on imaging is also analyzed. In addition, the similarities and differences among ghost imaging by fourth-, second-, and third-order correlations are also discussed. It is shown that the contrast and visibility of fourth-order correlated imaging are improved significantly, while the resolution is unchanged. Such studies can be very useful in better understanding multi photon interference and multi-channel correlation imaging.

Journal of the Physical Society of Japan•Sep 22, 2014•6 citations

Observation of Nontrivial 3-Photon Correlation of Chaotic Thermal Light

Yu Zhou, Jianbin Liu, Yanhua H. Shih

The reported experiment observed a nontrivial third-order temporal correlation of chaotic-thermal light in the joint-detection of three individual photodetectors. It seems that the thermal photons are always “bunched” in triples. In the view of quantum mechanics, “three-photon bunching” is a three-photon interference effect.

Conference on Lasers and Electro-Optics•Jan 1, 2009•0 citations

High-order photon correlations through double Hanbury Brown–Twiss measurements

Yanqiang Guo, Lijing Wang, Yu Wang +4 more

Abstract We present an experimental technique that can accurately measure the high-order photon correlations of various light fields based on double Hanbury Brown–Twiss scheme. The system consists of four conventional binary response single-photon counting modules which are non-photon-number-resolving detectors. We theoretically analyze the effects of the experimental conditions on the high-order photon correlations of coherent, chaotic thermal, Fock and squeezed vacuum states with considering the overall efficiency and background noise. In experiment, we determine the proper resolution time from 2 9 = 512 ns to 2 11 = 2048 ns and counting rate from 10 kc s −1 to 100 kc s −1 for characterizing the exact second-, third- and fourth-order photon correlations of chaotic thermal state. At complete time delays, we also observe the third- and fourth-order photon correlations of chaotic thermal state, with the maximum high-order correlation values of 5.99 ± 0.02 and 23.9 ± 0.2 respectively, which are in good agreement with the theoretical values of 6 and 24. The demonstrated experimental technique with high accuracy is a promising tool for investigating quantum optical coherence and ghost imaging.

Journal of Optics•Jul 7, 2020•10 citations

Resolution and Contrast Enhancement of Correlated Imaging in Photon Counting Regime

Feng Wen, Xun Zhang, Chenzhi Yuan +4 more

We theoretically discuss the four-photon spatial correlation property under different detection schemes. Compared with the two- and three-photon spatial correlation of thermal light source, we found that the enhancement in the visibility and the contrast when the fourth-order spatial correlation function is measured with quadruple coincidence measurement in the single photon counting regime. The resolution, however, is not changed when we scan three of four detectors with identical speed and direction. But if we scan two of three detectors in opposite directions and same speed, simultaneously, other two in identical direction and speed of one detector is twice of that of the other, we can see that both the contrast and resolution are improved significantly. We also show that the conclusion can be applied to the Nth-order ghost imaging.

Journal of the Physical Society of Japan•Sep 24, 2014•4 citations
In a near-field three-photon correlation measurement, we observed the third-order temporal and spatial correlation functions of chaotic thermal light in the single-photon counting regime. In the study, we found that the probability of jointly detecting three randomly radiated photons from a chaotic thermal source by three individual detectors is 666 times greater if the photodetection events fall in the coherence time and coherence area of the radiation field than if they do not. From the viewpoint of quantum mechanics, the observed phenomenon is the result of three-photon interference. By making use of this property, we measured the three-photon thermal light lensless ghost image of a double spot and achieved higher visibility compared with the two-photon thermal light ghost image.
Third-order Hanbrury Brown—Twiss and double-slit interference experiments with a pseudo-thermal light are performed by recording intensities in single, double and triple optical paths, respectively. The experimental results verifies the theoretical prediction that the indispensable condition for achieving a interference pattern or ghost image in N th-order intensity correlation measurements is the synchronous detection of the same light field by each reference detector, no matter the intensities recorded in one, or two, or N optical paths. It is shown that, when the reference detectors are scanned in the opposite directions, the visibility and resolution of the third-order spatial correlation function of thermal light is much better than that scanned in the same direction, but it is no use for obtaining the N th-order interference pattern or ghost image in the thermal N th-order interference or ghost imaging.
We investigate the fourth-order spatial correlation properties of pseudo-thermal light in the photon counting regime, and apply the Klyshko advanced-wave picture to describe the process of four-photon coincidence counting measurement. We deduce the theory of a proof-of-principle four-photon coincidence counting configuration, and find that if the four randomly radiated photons come from the same radiation area and are indistinguishable in principle, the fourth-order correlation of them is 24 times larger than that when four photons come from different radiation areas. In addition, we also show that the higher-order spatial correlation function can be decomposed into multiple lower-order correlation functions, and the contrast and visibility of low-order correlation peaks are less than those of higher orders, while the resolutions all are identical. This study may be useful for better understanding the four-photon interference and multi-channel correlation imaging.
In a near-field four-photon correlation measurement, ghost imaging with classical incoherent light is investigated. By applying the Klyshko advanced-wave picture, we consider the properties of four-photon spatial correlation and find that the fourth-order spatial correlation function can be decomposed into multiple lower-order correlation functions. On the basis of the spatial correlation properties, a proof-of-principle four-photon ghost imaging is proposed, and the effect of each part in a fourth-order correlation function on imaging is also analyzed. In addition, the similarities and differences among ghost imaging by fourth-, second-, and third-order correlations are also discussed. It is shown that the contrast and visibility of fourth-order correlated imaging are improved significantly, while the resolution is unchanged. Such studies can be very useful in better understanding multi photon interference and multi-channel correlation imaging.
Abstract We present an experimental technique that can accurately measure the high-order photon correlations of various light fields based on double Hanbury Brown–Twiss scheme. The system consists of four conventional binary response single-photon counting modules which are non-photon-number-resolving detectors. We theoretically analyze the effects of the experimental conditions on the high-order photon correlations of coherent, chaotic thermal, Fock and squeezed vacuum states with considering the overall efficiency and background noise. In experiment, we determine the proper resolution time from 2 9 = 512 ns to 2 11 = 2048 ns and counting rate from 10 kc s −1 to 100 kc s −1 for characterizing the exact second-, third- and fourth-order photon correlations of chaotic thermal state. At complete time delays, we also observe the third- and fourth-order photon correlations of chaotic thermal state, with the maximum high-order correlation values of 5.99 ± 0.02 and 23.9 ± 0.2 respectively, which are in good agreement with the theoretical values of 6 and 24. The demonstrated experimental technique with high accuracy is a promising tool for investigating quantum optical coherence and ghost imaging.
We theoretically discuss the four-photon spatial correlation property under different detection schemes. Compared with the two- and three-photon spatial correlation of thermal light source, we found that the enhancement in the visibility and the contrast when the fourth-order spatial correlation function is measured with quadruple coincidence measurement in the single photon counting regime. The resolution, however, is not changed when we scan three of four detectors with identical speed and direction. But if we scan two of three detectors in opposite directions and same speed, simultaneously, other two in identical direction and speed of one detector is twice of that of the other, we can see that both the contrast and resolution are improved significantly. We also show that the conclusion can be applied to the Nth-order ghost imaging.