Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Express

Temporal correlation of photons following frequency up-conversion

Lijun Ma, Matthew T. Rakher, Martin J. Stevens, Oliver Slattery, Kartik A. Srinivasan, Xiao Hong Tang

Published May 12, 2011• 19 citations
Publisher

Abstract

We demonstrate an approach to measure temporal correlations of photons in the near infrared range using frequency up-conversion. In this approach, the near infrared signal photons are converted into the visible range, in which highly efficient silicon avalanche photodiodes are used to perform the temporal correlation measurements. A coherent light source and a pseudo-thermal light source were used in the experiment. The results are in agreement with theoretical values and those obtained from measurements directly made using superconducting nanowire single photon detectors. We conclude that the temporal correlation (up to 4th order) of photons was preserved in the frequency up-conversion process. We further theoretically and experimentally studied the influence of the dark counts on the measurement. The setup uses commercially available components and achieves high total detection efficiency (~26%).

DOI
10.1364/oe.19.010501

Related papers

High efficiency single photon detection via frequency up-conversion

Aaron P. VanDevender, Paul G. Kwiat

We propose a method of single photon detection of infrared (IR) photons at potentially higher efficiencies and lower noise than allowed by traditional IR band avalanche photodiodes (APDs). By up-converting the photon from the IR, e.g. 1550 nm, to a visible wavelength in a nonlinear crystal, we can utilize the much higher efficiency of silicon APDs at these wavelengths. We have used a periodically poled lithium niobate (PPLN) crystal and a pulsed 1064 nm Nd:YAG laser to perform the up-conversion to a 631 nm photon. We observed conversion efficiencies as high as ∼ 80%, and demonstrated scaling down to the single photon level while maintaining a background of 3 ×s; 10−4 dark counts per count. We also propose a 2-crystal extension of this scheme, whereby orthogonal polarizations may be up-converted coherently, thus enabling complete quantum state transduction of arbitrary states.

Journal of Modern Optics•Jan 1, 2004•29 citations

High efficiency single photon detection via frequency up-conversion

Aaron P. VanDevender, Paul G. Kwiat

We propose a method of single photon detection of infrared (IR) photons at potentially higher efficiencies and lower noise than allowed by traditional IR band avalanche photodiodes (APDs). By up-converting the photon from the IR, e.g. 1550 nm, to a visible wavelength in a nonlinear crystal, we can utilize the much higher efficiency of silicon APDs at these wavelengths. We have used a periodically poled lithium niobate (PPLN) crystal and a pulsed 1064 nm Nd:YAG laser to perform the up-conversion to a 631 nm photon. We observed conversion efficiencies as high as ∼ 80%, and demonstrated scaling down to the single photon level while maintaining a background of 3 ×s; 10−4 dark counts per count. We also propose a 2-crystal extension of this scheme, whereby orthogonal polarizations may be up-converted coherently, thus enabling complete quantum state transduction of arbitrary states.

Journal of Modern Optics•Jun 1, 2004•214 citations

Preservation of High-Order Photon Correlations Following Frequency Up-conversion

Lijun Ma, Matthew T. Rakher, Martin J. Stevens +3 more

We demonstrate an efficient approach to measure temporal correlations for near-infrared photons using frequency up-conversion and observe that photon statistics are preserved during this process. The influence of noise photons on the measurement is studied.

Nonlinear Optics•Jan 1, 2011•1 citation

New results on single-photon upconversion

Aaron P. VanDevender, Paul G. Kwiat

The process of up-conversion is shown to enable superior single-photon detectors in the infrared, compared to InGaAs and germanium Avalanche Photodiodes (APDs) (normally used for IR single photon detection). After up-converting an infrared photon to a visible one in a non-linear crystal-Periodically Poled Lithium Niobate (PPLN)-we use a silicon APD to efficiently detect the frequency up-shifted IR photon. We have demonstrated this process at the "high-intensity" level and at the single-photon level, where the up-converted state is effectively a superposition of the single photon Fock state and the vacuum state. We achieve an 80% conversion efficiency over the width of the pulse, and show that this process is coherent, a necessary ingredient for many applications.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Oct 19, 2004•1 citation

High-efficiency single photon detection via frequency up-conversion

Aaron P. VanDevender, Paul G. Kwiat

We propose a method of single photon detection of infrared (IR) photons at potentially higher efficiencies and lower noise than allowed by traditional IR band Avalanche Photodiodes (APD). By up-converting the photon from IR, e.g., 1550 nm, to a visible wavelength in a nonlinear crystal, we can utilize the much higher efficiency of visible wavelength APDs. We have used a nonlinear crystal -- Periodically Poled Lithium Niobate (PPLN) -- and a pulsed 1064-nm Nd:YAG laser to perform the up-conversion to a 631-nm photon. When properly quasi-phase-matched, PPLN provides a large enough second order nonlinear susceptibility that near unit conversion efficiency of the IR photon into the visible should be possible. We have been able to observe peak conversion efficiencies as high as 80%, and have demonstrated scaling down to the single photon level while maintaining a background of 3 x 10-4 dark counts/count. Since the PPLN only acts on one polarization of the single photon, we also propose a 2-crystal extension of this scheme whereby orthogonal polarizations may be up-converted coherently, thereby enabling complete quantum state transduction.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 5, 2003•8 citations

Improved photon counting efficiency calibration using superconducting single photon detectors

Haiyong Gan, Nan Xu, Jianwei Li +9 more

The quantum efficiency of photon counters can be measured with standard uncertainty below 1% level using correlated photon pairs generated through spontaneous parametric down-conversion process. Normally a laser in UV, blue or green wavelength range with sufficient photon energy is applied to produce energy and momentum conserved photon pairs in two channels with desired wavelengths for calibration. One channel is used as the heralding trigger, and the other is used for the calibration of the detector under test. A superconducting nanowire single photon detector with advantages such as high photon counting speed (<20 MHz), low dark count rate (<50 counts per second), and wideband responsivity (UV to near infrared) is used as the trigger detector, enabling correlated photons calibration capabilities into shortwave visible range. For a 355nm single longitudinal mode pump laser, when a superconducting nanowire single photon detector is used as the trigger detector at 1064nm and 1560nm in the near infrared range, the photon counting efficiency calibration capabilities can be realized at 532nm and 460nm. The quantum efficiency measurement on photon counters such as photomultiplier tubes and avalanche photodiodes can be then further extended in a wide wavelength range (e.g. 400-1000nm) using a flat spectral photon flux source to meet the calibration demands in cutting edge low light applications such as time resolved fluorescence and nonlinear optical spectroscopy, super resolution microscopy, deep space observation, and so on.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Oct 15, 2015•0 citations
We demonstrate an approach to measure temporal correlations of photons in the near infrared range using frequency up-conversion. In this approach, the near infrared signal photons are converted into the visible range, in which highly efficient silicon avalanche photodiodes are used to perform the temporal correlation measurements. A coherent light source and a pseudo-thermal light source were used in the experiment. The results are in agreement with theoretical values and those obtained from measurements directly made using superconducting nanowire single photon detectors. We conclude that the temporal correlation (up to 4th order) of photons was preserved in the frequency up-conversion process. We further theoretically and experimentally studied the influence of the dark counts on the measurement. The setup uses commercially available components and achieves high total detection efficiency (~26%).
We propose a method of single photon detection of infrared (IR) photons at potentially higher efficiencies and lower noise than allowed by traditional IR band avalanche photodiodes (APDs). By up-converting the photon from the IR, e.g. 1550 nm, to a visible wavelength in a nonlinear crystal, we can utilize the much higher efficiency of silicon APDs at these wavelengths. We have used a periodically poled lithium niobate (PPLN) crystal and a pulsed 1064 nm Nd:YAG laser to perform the up-conversion to a 631 nm photon. We observed conversion efficiencies as high as ∼ 80%, and demonstrated scaling down to the single photon level while maintaining a background of 3 ×s; 10−4 dark counts per count. We also propose a 2-crystal extension of this scheme, whereby orthogonal polarizations may be up-converted coherently, thus enabling complete quantum state transduction of arbitrary states.
We propose a method of single photon detection of infrared (IR) photons at potentially higher efficiencies and lower noise than allowed by traditional IR band avalanche photodiodes (APDs). By up-converting the photon from the IR, e.g. 1550 nm, to a visible wavelength in a nonlinear crystal, we can utilize the much higher efficiency of silicon APDs at these wavelengths. We have used a periodically poled lithium niobate (PPLN) crystal and a pulsed 1064 nm Nd:YAG laser to perform the up-conversion to a 631 nm photon. We observed conversion efficiencies as high as ∼ 80%, and demonstrated scaling down to the single photon level while maintaining a background of 3 ×s; 10−4 dark counts per count. We also propose a 2-crystal extension of this scheme, whereby orthogonal polarizations may be up-converted coherently, thus enabling complete quantum state transduction of arbitrary states.
The process of up-conversion is shown to enable superior single-photon detectors in the infrared, compared to InGaAs and germanium Avalanche Photodiodes (APDs) (normally used for IR single photon detection). After up-converting an infrared photon to a visible one in a non-linear crystal-Periodically Poled Lithium Niobate (PPLN)-we use a silicon APD to efficiently detect the frequency up-shifted IR photon. We have demonstrated this process at the "high-intensity" level and at the single-photon level, where the up-converted state is effectively a superposition of the single photon Fock state and the vacuum state. We achieve an 80% conversion efficiency over the width of the pulse, and show that this process is coherent, a necessary ingredient for many applications.
We propose a method of single photon detection of infrared (IR) photons at potentially higher efficiencies and lower noise than allowed by traditional IR band Avalanche Photodiodes (APD). By up-converting the photon from IR, e.g., 1550 nm, to a visible wavelength in a nonlinear crystal, we can utilize the much higher efficiency of visible wavelength APDs. We have used a nonlinear crystal -- Periodically Poled Lithium Niobate (PPLN) -- and a pulsed 1064-nm Nd:YAG laser to perform the up-conversion to a 631-nm photon. When properly quasi-phase-matched, PPLN provides a large enough second order nonlinear susceptibility that near unit conversion efficiency of the IR photon into the visible should be possible. We have been able to observe peak conversion efficiencies as high as 80%, and have demonstrated scaling down to the single photon level while maintaining a background of 3 x 10-4 dark counts/count. Since the PPLN only acts on one polarization of the single photon, we also propose a 2-crystal extension of this scheme whereby orthogonal polarizations may be up-converted coherently, thereby enabling complete quantum state transduction.
The quantum efficiency of photon counters can be measured with standard uncertainty below 1% level using correlated photon pairs generated through spontaneous parametric down-conversion process. Normally a laser in UV, blue or green wavelength range with sufficient photon energy is applied to produce energy and momentum conserved photon pairs in two channels with desired wavelengths for calibration. One channel is used as the heralding trigger, and the other is used for the calibration of the detector under test. A superconducting nanowire single photon detector with advantages such as high photon counting speed (<20 MHz), low dark count rate (<50 counts per second), and wideband responsivity (UV to near infrared) is used as the trigger detector, enabling correlated photons calibration capabilities into shortwave visible range. For a 355nm single longitudinal mode pump laser, when a superconducting nanowire single photon detector is used as the trigger detector at 1064nm and 1560nm in the near infrared range, the photon counting efficiency calibration capabilities can be realized at 532nm and 460nm. The quantum efficiency measurement on photon counters such as photomultiplier tubes and avalanche photodiodes can be then further extended in a wide wavelength range (e.g. 400-1000nm) using a flat spectral photon flux source to meet the calibration demands in cutting edge low light applications such as time resolved fluorescence and nonlinear optical spectroscopy, super resolution microscopy, deep space observation, and so on.