Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Symposium on Frequency Standards and Metrology

OPTICAL LATTICE CLOCK WITH Sr ATOMS

Philip G. Westergaard, Arnaud Lecallier, Jérôme Lodewyck, P. Lemonde

Published May 1, 2009• 0 citations
Publisher

Abstract

We review the recent progress at LNE-SYRTE on an optical lattice clock using Sr atoms. We discuss the required lattice depth to cancel motional effects in such a clock and show that a relatively small lattice depth is sufficient provided the lattice is oriented vertically. We also demonstrate an accurate frequency measurement of the Sr clock transition with accuracy in the low 10 -15 range. Finally, we describe a new non-destructive method to detect the atoms in the clock and discuss the expected associated improvement in the frequency stability of the clock.

DOI
10.1142/9789812838223_0022

Related papers

OPTICAL LATTICE CLOCK: SEVEN YEARS OF PROGRESS AND NEXT STEPS

Hidetoshi Katori, Masao Takamoto, Tomoya Akatsuka

We discuss configurations of optical lattice clocks from the viewpoint of lattice geometries and quantum statistics of interrogated atoms. This leads to two promising schemes: a one-dimensional lattice loaded with spin-polarized fermions and a three-dimensional lattice loaded with bosons. These two optical lattice clocks based on fermionic 87 Sr and bosonic 88 Sr were demonstrated by measuring the frequency stability as well as their isotope shift. In addition, we address the ongoing experimental challenges for optical lattice clocks.

Symposium on Frequency Standards and Metrology•May 1, 2009•0 citations

AN OPTICAL LATTICE CLOCK: ULTRASTABLE ATOMIC CLOCK WITH ENGINEERED PERTURBATION

Hidetoshi Katori, Masao Takamoto, Ryoichi Higashi +1 more

An optical lattice clock was realized for 87 Sr atoms and its absolute frequency has been measured. Projected uncertainty in the lattice clock is illustrated for the case of 87 Sr . We discuss application of the clock scheme to other atom species, in search for better lattice clocks as well as for the variation of fine-structure constant.

Foundations of Quantum Mechanics in the Light of New Technology•Jun 1, 2006•0 citations

SR OPTICAL CLOCK WITH HIGH STABILITY AND ACCURACY

Andrew D. Ludlow, Sebastian Blatt, M. BOYD +12 more

We report on our recent evaluations of stability and accuracy of the JILA Sr optical lattice clock. We discuss precision tools for the lattice clock, including a stabilized clock laser with sub-Hz linewidth, fs-comb based technology allowing accurate clock comparison in both the microwave and optical domains, and clock transfer over optical fiber in an urban environment. High resolution spectroscopy ( Q > 2 × 10 14 ) of lattice-confined, spin-polarized strontium atoms is used for both a high-performance optical clock and atomic structure measurement. Using a Ca optical standard for comparison, the overall systematic uncertainty of the Sr clock is reduced to < 2 × 10 −16 .

Laser Spectroscopy•Apr 1, 2008•0 citations

Horloge à réseau optique au Strontium : en quête de la performance ultime

Philip G. Westergaard

This thesis presents the latest achievements regarding the Sr optical lattice clock experiment at LNE-SYRTE, Observatoire de Paris. After having described the general principles for optical lattice clocks and the operation of the clock in question, the emphasis is put on the features that have been added to the experiment since 2007. The most important new elements are an ultra-stable reference cavity for the clock laser, the development of a non-destructive detection technique, and the construction of a second Sr lattice clock. The ultra-stable cavity is constructed from a ULE spacer and fused silica mirrors and has shown a thermal noise floor at 6.5E-16, placing it among the best in the world. The non-destructive detection is effectuated by a phase measurement of a weak probe beam that traverses the atoms placed in one arm of a Mach-Zender interferometer. The non-destructive aspect enables a recycling of the atoms from cycle to cycle which consequently increases the duty cycle, allowing for an increase of the stability of the clock. With these new tools the frequency stability is expected to be 2.2E-16/tau^(1/2) for an optimized sequence. The most recent comparisons between the two Sr clocks reach an accuracy level of 1E-16 after about 1000 s, and this way we have been able to characterize lattice related frequency shifts with an unprecedented accuracy. The measurements ensure a control of lattice related effects at the 1E-18 level even for trap depths as large as 50 Er.

•Jan 1, 2010•6 citations

Developments to improve the stability of optical lattice clocks

S. Bize, Bess Fang, Yann Le Coq +5 more

We present several developments aimed at improving the stability of optical lattice clocks. First, we present our developments of an optical lattice clock using neutral mercury. We mention recent advances made with the fermionic isotope 199Hg. We also mention our work aimed at using bosonic isotopes, which offer the possibility to circumvent the relatively short lifetime of the upper clock state in 199Hg. Second, we present our work on a non-destructive detection in a Sr optical lattice clock. We describe developments that brought the detection scheme from the classical non-destructive regime to the quantum non-destructive regime. Our detection scheme is practical and has the capability to the used beyond proving the principle. Finally, we present our work on laser stabilization using spectral hole burning in a Eu3+:Y2SiO5 crystal at cryogenic temperatures. We describe our development of low noise interrogation based on digital IQ modulation and detection that can probe multiple spectral features simultaneously, as well as several investigations towards fluctuating environmental factors. These advances, individually or combined for example with spectral purity transfer with combs and composite clock approaches, shall bring significant progress in clock stability and accuracy.

Journal of Physics Conference Series•Nov 1, 2024•1 citation

OPTICAL LATTICE CLOCK: PRECISION SPECTROSCOPY OF NEUTRAL ATOMS IN TIGHT CONFINEMENT

Hidetoshi Katori, Masao Takamoto

We report on the spectroscopy of the 5s 2 1 S 0 (F = 9/2) → 5s5p 3 P 0 (F = 9/2) clock transition of 87 Sr atoms (natural linewidth of 1 mHz) trapped in a one-dimensional optical lattice. A recoilless transition with a linewidth of 0.7 kHz was observed for the trap laser wavelength λ ≈ 813 nm, where the light shift in the clock transition canceled out. We discuss the feasibility of realizing an optical frequency standard based on this scheme.

Laser Spectroscopy•Feb 1, 2004•0 citations
We review the recent progress at LNE-SYRTE on an optical lattice clock using Sr atoms. We discuss the required lattice depth to cancel motional effects in such a clock and show that a relatively small lattice depth is sufficient provided the lattice is oriented vertically. We also demonstrate an accurate frequency measurement of the Sr clock transition with accuracy in the low 10 -15 range. Finally, we describe a new non-destructive method to detect the atoms in the clock and discuss the expected associated improvement in the frequency stability of the clock.
We discuss configurations of optical lattice clocks from the viewpoint of lattice geometries and quantum statistics of interrogated atoms. This leads to two promising schemes: a one-dimensional lattice loaded with spin-polarized fermions and a three-dimensional lattice loaded with bosons. These two optical lattice clocks based on fermionic 87 Sr and bosonic 88 Sr were demonstrated by measuring the frequency stability as well as their isotope shift. In addition, we address the ongoing experimental challenges for optical lattice clocks.
We report on our recent evaluations of stability and accuracy of the JILA Sr optical lattice clock. We discuss precision tools for the lattice clock, including a stabilized clock laser with sub-Hz linewidth, fs-comb based technology allowing accurate clock comparison in both the microwave and optical domains, and clock transfer over optical fiber in an urban environment. High resolution spectroscopy ( Q > 2 × 10 14 ) of lattice-confined, spin-polarized strontium atoms is used for both a high-performance optical clock and atomic structure measurement. Using a Ca optical standard for comparison, the overall systematic uncertainty of the Sr clock is reduced to < 2 × 10 −16 .
This thesis presents the latest achievements regarding the Sr optical lattice clock experiment at LNE-SYRTE, Observatoire de Paris. After having described the general principles for optical lattice clocks and the operation of the clock in question, the emphasis is put on the features that have been added to the experiment since 2007. The most important new elements are an ultra-stable reference cavity for the clock laser, the development of a non-destructive detection technique, and the construction of a second Sr lattice clock. The ultra-stable cavity is constructed from a ULE spacer and fused silica mirrors and has shown a thermal noise floor at 6.5E-16, placing it among the best in the world. The non-destructive detection is effectuated by a phase measurement of a weak probe beam that traverses the atoms placed in one arm of a Mach-Zender interferometer. The non-destructive aspect enables a recycling of the atoms from cycle to cycle which consequently increases the duty cycle, allowing for an increase of the stability of the clock. With these new tools the frequency stability is expected to be 2.2E-16/tau^(1/2) for an optimized sequence. The most recent comparisons between the two Sr clocks reach an accuracy level of 1E-16 after about 1000 s, and this way we have been able to characterize lattice related frequency shifts with an unprecedented accuracy. The measurements ensure a control of lattice related effects at the 1E-18 level even for trap depths as large as 50 Er.
We present several developments aimed at improving the stability of optical lattice clocks. First, we present our developments of an optical lattice clock using neutral mercury. We mention recent advances made with the fermionic isotope 199Hg. We also mention our work aimed at using bosonic isotopes, which offer the possibility to circumvent the relatively short lifetime of the upper clock state in 199Hg. Second, we present our work on a non-destructive detection in a Sr optical lattice clock. We describe developments that brought the detection scheme from the classical non-destructive regime to the quantum non-destructive regime. Our detection scheme is practical and has the capability to the used beyond proving the principle. Finally, we present our work on laser stabilization using spectral hole burning in a Eu3+:Y2SiO5 crystal at cryogenic temperatures. We describe our development of low noise interrogation based on digital IQ modulation and detection that can probe multiple spectral features simultaneously, as well as several investigations towards fluctuating environmental factors. These advances, individually or combined for example with spectral purity transfer with combs and composite clock approaches, shall bring significant progress in clock stability and accuracy.