Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Horloge à réseau optique au Strontium : en quête de la performance ultime

Philip G. Westergaard

Published Jan 1, 2010• 0 citations
OpenAlex

Abstract

This thesis presents the latest achievements regarding the Sr optical lattice clock experiment at LNE-SYRTE, Observatoire de Paris. After having described the general principles for optical lattice clocks and the operation of the clock in question, the emphasis is put on the features that have been added to the experiment since 2007. The most important new elements are an ultra-stable reference cavity for the clock laser, the development of a non-destructive detection technique, and the construction of a second Sr lattice clock. The ultra-stable cavity is constructed from a ULE spacer and fused silica mirrors and has shown a thermal noise floor at 6.5E-16, placing it among the best in the world. The non-destructive detection is effectuated by a phase measurement of a weak probe beam that traverses the atoms placed in one arm of a Mach-Zender interferometer. The non-destructive aspect enables a recycling of the atoms from cycle to cycle which consequently increases the duty cycle, allowing for an increase of the stability of the clock. With these new tools the frequency stability is expected to be 2.2E-16/tau^(1/2) for an optimized sequence. The most recent comparisons between the two Sr clocks reach an accuracy level of 1E-16 after about 1000 s, and this way we have been able to characterize lattice related frequency shifts with an unprecedented accuracy. The measurements ensure a control of lattice related effects at the 1E-18 level even for trap depths as large as 50 Er.

Related papers

Strontium Optical Lattice Clock: In Quest of the Ultimate Performance

Philip G. Westergaard

This thesis presents the latest achievements regarding the Sr optical lattice clock experiment at LNE-SYRTE, Observatoire de Paris. After having described the general principles for optical lattice clocks and the operation of the clock in question, the emphasis is put on the features that have been added to the experiment since 2007. The most important new elements are an ultra-stable reference cavity for the clock laser, the development of a non-destructive detection technique, and the construction of a second Sr lattice clock. The ultra-stable cavity is constructed from a ULE spacer and fused silica mirrors and has shown a thermal noise floor at 6.5E-16, placing it among the best in the world. The non-destructive detection is effectuated by a phase measurement of a weak probe beam that traverses the atoms placed in one arm of a Mach-Zender interferometer. The non-destructive aspect enables a recycling of the atoms from cycle to cycle which consequently increases the duty cycle, allowing for an increase of the stability of the clock. With these new tools the frequency stability is expected to be 2.2E-16/tau^(1/2) for an optimized sequence. The most recent comparisons between the two Sr clocks reach an accuracy level of 1E-16 after about 1000 s, and this way we have been able to characterize lattice related frequency shifts with an unprecedented accuracy. The measurements ensure a control of lattice related effects at the 1E-18 level even for trap depths as large as 50 Er.

•Oct 29, 2010•2 citations

Strontium optical lattice clocks at LNE-SYRTE

Chunyan Shi, Ulrich Eismann, Jean-Luc Robyr +3 more

In optical lattice clocks, a large number of neutral atoms confined in an optical lattice are probed by a narrow linewidth laser. These clocks combine an excellent control of the systematic effects, while offering a record stability thanks to the large number of interrogated atoms. Here, we report on recent results obtained with two strontium optical lattice clocks at LNE-SYRTE, Observatoire de Paris.

Conference on Precision Electromagnetic Measurements•Aug 1, 2014•0 citations

Détection non destructive en cavité pour des horloges à réseau optique au strontium

Grégoire Vallet

The work achieved in the frame of this PhD training consisted in the implementation of a cavity enhanced non destructive detection system of atoms trapped in an optical lattice aiming at improving the stability of an optical strontium clock.The characterization of the system in its classical regime, for which a sufficiently low number of photons are scattered per atom to avoid expelling them off the trap, highlighted significant improvements in term of signal to noise ratio, with gain factor around 100 compared with the previously used fluorescence scheme. Yet, gains in terms of stability via Dick effect reduction still have to be demonstrated.Regarding the quantum regime, for which less than one photon is scattered per atom over the detection, new ideas and significant changes have been carried out on the system and a theoretical study was has been undertaken to determine the strategy for the improvement of the clock stability by quantum projection noise reduction via quantum non demolition measurement.It was as well the opportunity to study the effect of the hot collisions between the trapped strontium atoms and the residual vacuum background gas particles, allowing for the improvement of the clock uncertainty. This work reports in particular on the first measurement of strontium clock hot collisions shifts as well as its theoretical study.

•Dec 13, 2018•0 citations

Contributing to TAI with Sr optical lattice clocks

Sławomir Bilicki, Eva Bookjans, Grégoire Vallet +3 more

In this paper, we present recent experiments conducted with two87Sr optical lattice clocks operated at LNE-SYRTE. We report on the first calibrations of TAI with optical clocks, a necessary step towards the redefinition of the SI second. Additionally, we report on the experimental realization of a cavity-assisted non-destructive detection whose improved signal-to-noise ratio can improve the stability of optical clocks by reducing the Dick effect instability contribution, possibly beyond the quantum projection noise. Finally, we discuss the possibility to operate lattice clocks with semi-conductor sources as a lattice trap laser, by evaluating the frequency shift induced by their incoherent background light.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2017•1 citation

Frequency stability of optical lattice clocks

Jérôme Lodewyck, Philip G. Westergaard, Arnaud Lecallier +2 more

In this paper, we review several aspects of the frequency stability of optical lattice clocks. We describe a new ultra-stable cavity design with reduced thermal noise and record frequency stability (below 10 −15 ), as well as a non-destructive detection scheme for measuring the clock transition probability. Given the experimental parameters we measured, we simulate different sequence strategies for optimizing the stability. Finally, we report on the development of a second optical lattice clock and simulate several comparison strategies. In particular, we show by a numerical method that a stability as low as 2 × 10 −16 τ −1/2 can be reached with optical lattice clocks, and we show how to demonstrate this stability with a double clock system.

New Journal of Physics•Jun 28, 2010•33 citations

Spectroscopy schemes for improved optical clock stability

Filip Butuc-Mayer

Frequency metrology underpins precise measurements. At the forefront of this field are optical clocks which can perform measurements that are accurate to more digits than those in the number representing seconds elapsed from the beginning of the universe. Frequency estimation errors in the operation of optical clocks lead to frequency instability, prohibiting them from reaching high accuracies on short to medium time scales, and limiting access to interesting measurements of the atomic environment and exotic external perturbations such as gravity fields or fields of fundamentally new physical origins. Optical lattice traps are typically employed in state-of-the-art optical clocks to suppress Doppler effects. By carefully tuning the optical lattice to the magic wavelength, unwanted Stark shifts can be suppressed significantly, allowing operation with thousands of atoms and minimising the fundamental source of frequency estimation errors, namely the quantum projection noise, to around 3 × 10−17 at 1 s. In this thesis, the status of the two Strontium optical lattice clocks at NPL, Sr1 and Sr2, is presented going over a few interesting measurement campaigns from the past years involving Sr1 and the latest experimental efforts to re-enable operation of Sr2. A model of clock stability is developed by incorporating known and new frameworks to characterise the relation between the operating parameters of optical clocks and their performance, with relevance to the NPL lattice clocks and beyond. In particular, a method is identified for addressing the main technical noise for optical lattice clocks, the Dick effect, which typically has a magnitude of 10−16 at 1 s and prevents optical lattice clocks from reaching the quantum projection noise level. By taking advantage of dynamical decoupling we can engineer an optimised duty cycle with benefits in general for systems limited by the optical coherence of the clock laser. Moreover, a study of other noise sources in the NPL lattice clocks is conducted using synchronous measurements between Sr1 and Sr2, revealing a large contribution from linear Zeeman shifts, also at the 10−16 level, and a plan to tackle them is detailed. A hybrid clock architecture is discussed showing how optical lattice clocks can improve the optical coherence of ion clocks thanks to their higher servo rate, and a preliminary experimental demonstration is reported. Finally, a new type of spectroscopy is presented which completely avoids aliasing of linear Zeeman shifts by simultaneously driving transitions with opposite Zeeman sensitivities. Such a technique also enables the continuous interrogation of atoms, a crucial missing component in the Dick-free conveyor belt lattice clock concept heralded as the next standard of stable optical clocks.

•Jan 1, 2026•0 citations
This thesis presents the latest achievements regarding the Sr optical lattice clock experiment at LNE-SYRTE, Observatoire de Paris. After having described the general principles for optical lattice clocks and the operation of the clock in question, the emphasis is put on the features that have been added to the experiment since 2007. The most important new elements are an ultra-stable reference cavity for the clock laser, the development of a non-destructive detection technique, and the construction of a second Sr lattice clock. The ultra-stable cavity is constructed from a ULE spacer and fused silica mirrors and has shown a thermal noise floor at 6.5E-16, placing it among the best in the world. The non-destructive detection is effectuated by a phase measurement of a weak probe beam that traverses the atoms placed in one arm of a Mach-Zender interferometer. The non-destructive aspect enables a recycling of the atoms from cycle to cycle which consequently increases the duty cycle, allowing for an increase of the stability of the clock. With these new tools the frequency stability is expected to be 2.2E-16/tau^(1/2) for an optimized sequence. The most recent comparisons between the two Sr clocks reach an accuracy level of 1E-16 after about 1000 s, and this way we have been able to characterize lattice related frequency shifts with an unprecedented accuracy. The measurements ensure a control of lattice related effects at the 1E-18 level even for trap depths as large as 50 Er.
This thesis presents the latest achievements regarding the Sr optical lattice clock experiment at LNE-SYRTE, Observatoire de Paris. After having described the general principles for optical lattice clocks and the operation of the clock in question, the emphasis is put on the features that have been added to the experiment since 2007. The most important new elements are an ultra-stable reference cavity for the clock laser, the development of a non-destructive detection technique, and the construction of a second Sr lattice clock. The ultra-stable cavity is constructed from a ULE spacer and fused silica mirrors and has shown a thermal noise floor at 6.5E-16, placing it among the best in the world. The non-destructive detection is effectuated by a phase measurement of a weak probe beam that traverses the atoms placed in one arm of a Mach-Zender interferometer. The non-destructive aspect enables a recycling of the atoms from cycle to cycle which consequently increases the duty cycle, allowing for an increase of the stability of the clock. With these new tools the frequency stability is expected to be 2.2E-16/tau^(1/2) for an optimized sequence. The most recent comparisons between the two Sr clocks reach an accuracy level of 1E-16 after about 1000 s, and this way we have been able to characterize lattice related frequency shifts with an unprecedented accuracy. The measurements ensure a control of lattice related effects at the 1E-18 level even for trap depths as large as 50 Er.
The work achieved in the frame of this PhD training consisted in the implementation of a cavity enhanced non destructive detection system of atoms trapped in an optical lattice aiming at improving the stability of an optical strontium clock.The characterization of the system in its classical regime, for which a sufficiently low number of photons are scattered per atom to avoid expelling them off the trap, highlighted significant improvements in term of signal to noise ratio, with gain factor around 100 compared with the previously used fluorescence scheme. Yet, gains in terms of stability via Dick effect reduction still have to be demonstrated.Regarding the quantum regime, for which less than one photon is scattered per atom over the detection, new ideas and significant changes have been carried out on the system and a theoretical study was has been undertaken to determine the strategy for the improvement of the clock stability by quantum projection noise reduction via quantum non demolition measurement.It was as well the opportunity to study the effect of the hot collisions between the trapped strontium atoms and the residual vacuum background gas particles, allowing for the improvement of the clock uncertainty. This work reports in particular on the first measurement of strontium clock hot collisions shifts as well as its theoretical study.
In this paper, we present recent experiments conducted with two87Sr optical lattice clocks operated at LNE-SYRTE. We report on the first calibrations of TAI with optical clocks, a necessary step towards the redefinition of the SI second. Additionally, we report on the experimental realization of a cavity-assisted non-destructive detection whose improved signal-to-noise ratio can improve the stability of optical clocks by reducing the Dick effect instability contribution, possibly beyond the quantum projection noise. Finally, we discuss the possibility to operate lattice clocks with semi-conductor sources as a lattice trap laser, by evaluating the frequency shift induced by their incoherent background light.
In this paper, we review several aspects of the frequency stability of optical lattice clocks. We describe a new ultra-stable cavity design with reduced thermal noise and record frequency stability (below 10 −15 ), as well as a non-destructive detection scheme for measuring the clock transition probability. Given the experimental parameters we measured, we simulate different sequence strategies for optimizing the stability. Finally, we report on the development of a second optical lattice clock and simulate several comparison strategies. In particular, we show by a numerical method that a stability as low as 2 × 10 −16 τ −1/2 can be reached with optical lattice clocks, and we show how to demonstrate this stability with a double clock system.
Frequency metrology underpins precise measurements. At the forefront of this field are optical clocks which can perform measurements that are accurate to more digits than those in the number representing seconds elapsed from the beginning of the universe. Frequency estimation errors in the operation of optical clocks lead to frequency instability, prohibiting them from reaching high accuracies on short to medium time scales, and limiting access to interesting measurements of the atomic environment and exotic external perturbations such as gravity fields or fields of fundamentally new physical origins. Optical lattice traps are typically employed in state-of-the-art optical clocks to suppress Doppler effects. By carefully tuning the optical lattice to the magic wavelength, unwanted Stark shifts can be suppressed significantly, allowing operation with thousands of atoms and minimising the fundamental source of frequency estimation errors, namely the quantum projection noise, to around 3 × 10−17 at 1 s. In this thesis, the status of the two Strontium optical lattice clocks at NPL, Sr1 and Sr2, is presented going over a few interesting measurement campaigns from the past years involving Sr1 and the latest experimental efforts to re-enable operation of Sr2. A model of clock stability is developed by incorporating known and new frameworks to characterise the relation between the operating parameters of optical clocks and their performance, with relevance to the NPL lattice clocks and beyond. In particular, a method is identified for addressing the main technical noise for optical lattice clocks, the Dick effect, which typically has a magnitude of 10−16 at 1 s and prevents optical lattice clocks from reaching the quantum projection noise level. By taking advantage of dynamical decoupling we can engineer an optimised duty cycle with benefits in general for systems limited by the optical coherence of the clock laser. Moreover, a study of other noise sources in the NPL lattice clocks is conducted using synchronous measurements between Sr1 and Sr2, revealing a large contribution from linear Zeeman shifts, also at the 10−16 level, and a plan to tackle them is detailed. A hybrid clock architecture is discussed showing how optical lattice clocks can improve the optical coherence of ion clocks thanks to their higher servo rate, and a preliminary experimental demonstration is reported. Finally, a new type of spectroscopy is presented which completely avoids aliasing of linear Zeeman shifts by simultaneously driving transitions with opposite Zeeman sensitivities. Such a technique also enables the continuous interrogation of atoms, a crucial missing component in the Dick-free conveyor belt lattice clock concept heralded as the next standard of stable optical clocks.