Nonlinear Optics

Preservation of High-Order Photon Correlations Following Frequency Up-conversion

Lijun Ma, Matthew T. Rakher, Martin J. Stevens, Oliver Slattery, Kartik A. Srinivasan, Xiao Hong Tang

Published Jan 1, 2011• 1 citation
Publisher

Abstract

We demonstrate an efficient approach to measure temporal correlations for near-infrared photons using frequency up-conversion and observe that photon statistics are preserved during this process. The influence of noise photons on the measurement is studied.
DOI
10.1364/nlo.2011.nwc4

Related papers

Temporal correlation of photons following frequency up-conversion

Lijun Ma, Matthew T. Rakher, Martin J. Stevens +3 more

We demonstrate an approach to measure temporal correlations of photons in the near infrared range using frequency up-conversion. In this approach, the near infrared signal photons are converted into the visible range, in which highly efficient silicon avalanche photodiodes are used to perform the temporal correlation measurements. A coherent light source and a pseudo-thermal light source were used in the experiment. The results are in agreement with theoretical values and those obtained from measurements directly made using superconducting nanowire single photon detectors. We conclude that the temporal correlation (up to 4th order) of photons was preserved in the frequency up-conversion process. We further theoretically and experimentally studied the influence of the dark counts on the measurement. The setup uses commercially available components and achieves high total detection efficiency (~26%).

Optics Express•May 12, 2011•19 citations

Frequency Conversion of Narrowband Single Photons from a SPDC Pair Source

Andreas Lenhard, Stephan Kucera, José Luis Saquinaula Brito +2 more

We report on frequency down conversion of single photons from a photon pair source resonant with an atomic transition of Calcium ions. The temporal correlation between the photon pair is preserved in the conversion process.

•Jan 1, 2014•1 citation

Single photon frequency up-conversion and its applications

Lijun Ma, Oliver Slattery, Xiao Hong Tang

We have studied single photon level frequency up-conversion, and developed efficient single photon detectors and a highly sensitive spectrometer at a telecommunication wavelength (around 1310 nm). We have applied the detector and spectrometer to the implementation of a quantum key distribution system; to the characterization of an entangled photon source and a single photon source from quantum dots; to increase the temporal resolution of the single photon detector; and to study on high-order temporal correlation following frequency conversion. In this paper, we will present an overview on the frequency up-conversion technique and its applications in quantum information systems.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Sep 1, 2011•8 citations

Photon Temporal Correlations Measured Using a Dual-Channel Upconversion Detector

Paulina S. Kuo, Jason S. Pelc, Oliver Slattery +2 more

We demonstrate application of a dual-channel upconversion detector as a beamsplitter that preserves photon statistics. We use this beamsplitter to characterize temporal correlations of photons from coherent and pseudo-thermal sources.

Frontiers in Optics•Jan 1, 2012•2 citations

Polarization-preserving frequency conversion for high-efficiency photon counting and quantum communication

Marius A. Albotǎ, Franco N. C. Wong, Jeffrey H. Shapiro

We report polarization-independent upconversion from infrared to visible wavelengths. This technique enables high-efficiency continuous-wave photon counting at 1.55 /spl mu/m, and is necessary for quantum-state frequency translation and long-distance teleportation.

Quantum Electronics and Laser Science Conference•Dec 10, 2005•0 citations

Mid-infrared single-photon upconversion spectroscopy based on temporal-spectral quantum correlation

Yujie Cai, Yu Chen, Xiaoning Xin +2 more

Promoting the sensitivity of mid-infrared (MIR) spectroscopy to the single-photon level is a critical need for investigating photosensitive biological samples and chemical reactions. MIR spectroscopy based on frequency upconversion is a compelling pioneer allowing high-efficiency MIR spectral measurement with well-developed single-photon detectors, which overcomes the main limitations of high thermal noise of current MIR detectors. However, noise from other nonlinear processes caused by strong pump fields hinders the development of the upconversion-based MIR spectroscopy to reach the single-photon level. Here, a broadband MIR single-photon frequency upconversion spectroscopy is demonstrated based on the temporal-spectral quantum correlation of non-degenerate photon pairs, which is well preserved in the frequency upconversion process and is fully used in extracting the signals from tremendous noise caused by the strong pump. A correlation spectrum broader than 660 nm is achieved and applied for the demonstration of sample identification under a low incident photon flux of 0.09 average photons per pulse. The system is featured with non-destructive and robust operation, which makes single-photon-level MIR spectroscopy an appealing option in biochemical applications.

Photonics Research•Sep 22, 2022•28 citations
We demonstrate an approach to measure temporal correlations of photons in the near infrared range using frequency up-conversion. In this approach, the near infrared signal photons are converted into the visible range, in which highly efficient silicon avalanche photodiodes are used to perform the temporal correlation measurements. A coherent light source and a pseudo-thermal light source were used in the experiment. The results are in agreement with theoretical values and those obtained from measurements directly made using superconducting nanowire single photon detectors. We conclude that the temporal correlation (up to 4th order) of photons was preserved in the frequency up-conversion process. We further theoretically and experimentally studied the influence of the dark counts on the measurement. The setup uses commercially available components and achieves high total detection efficiency (~26%).
We have studied single photon level frequency up-conversion, and developed efficient single photon detectors and a highly sensitive spectrometer at a telecommunication wavelength (around 1310 nm). We have applied the detector and spectrometer to the implementation of a quantum key distribution system; to the characterization of an entangled photon source and a single photon source from quantum dots; to increase the temporal resolution of the single photon detector; and to study on high-order temporal correlation following frequency conversion. In this paper, we will present an overview on the frequency up-conversion technique and its applications in quantum information systems.
Promoting the sensitivity of mid-infrared (MIR) spectroscopy to the single-photon level is a critical need for investigating photosensitive biological samples and chemical reactions. MIR spectroscopy based on frequency upconversion is a compelling pioneer allowing high-efficiency MIR spectral measurement with well-developed single-photon detectors, which overcomes the main limitations of high thermal noise of current MIR detectors. However, noise from other nonlinear processes caused by strong pump fields hinders the development of the upconversion-based MIR spectroscopy to reach the single-photon level. Here, a broadband MIR single-photon frequency upconversion spectroscopy is demonstrated based on the temporal-spectral quantum correlation of non-degenerate photon pairs, which is well preserved in the frequency upconversion process and is fully used in extracting the signals from tremendous noise caused by the strong pump. A correlation spectrum broader than 660 nm is achieved and applied for the demonstration of sample identification under a low incident photon flux of 0.09 average photons per pulse. The system is featured with non-destructive and robust operation, which makes single-photon-level MIR spectroscopy an appealing option in biochemical applications.