Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

Single photon frequency up-conversion and its applications

Lijun Ma, Oliver Slattery, Xiao Hong Tang

Published Sep 1, 2011• 8 citations
Publisher

Abstract

We have studied single photon level frequency up-conversion, and developed efficient single photon detectors and a highly sensitive spectrometer at a telecommunication wavelength (around 1310 nm). We have applied the detector and spectrometer to the implementation of a quantum key distribution system; to the characterization of an entangled photon source and a single photon source from quantum dots; to increase the temporal resolution of the single photon detector; and to study on high-order temporal correlation following frequency conversion. In this paper, we will present an overview on the frequency up-conversion technique and its applications in quantum information systems.

DOI
10.1117/12.890980

Related papers

Frequency up-conversion single-photon detectors for quantum communication systems

Lijun Ma, Joshua C. Bienfang, Oliver Slattery +1 more

Frequency up-conversion technology can be used to increase detection efficiency for near infrared photons, as has been demonstrated in fiber-based quantum communication systems. In a continuous wave pumped up-conversion detector, the temporal resolution is limited by the timing jitter of the detector in the visible range, which limits the maximum clock rate of a quantum communication system. In this paper we describe a scheme to improve the temporal resolution of an up-conversion single-photon detector using multi-wavelength optical-sampling techniques, allowing for increased transmission rates in single-photon communications systems. We experimentally demonstrate our approach with an up-conversion detector using two spectrally and temporally distinct pump pulses, and show that it allows for high-fidelity single-photon detection at twice the rate supported by a conventional single-pump up-conversion detector.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 26, 2011•1 citation

Up-conversion single-photon detector using multi-wavelength sampling techniques

Lijun Ma, Joshua C. Bienfang, Oliver Slattery +1 more

The maximum achievable data-rate of a quantum communication system can be critically limited by the efficiency and temporal resolution of the system's single-photon detectors. Frequency up-conversion technology can be used to increase detection efficiency for IR photons. In this paper we describe a scheme to improve the temporal resolution of an up-conversion single-photon detector using multi-wavelength optical-sampling techniques, allowing for increased transmission rates in single-photon communications systems. We experimentally demonstrate our approach with an up-conversion detector using two spectrally and temporally distinct pump pulses, and show that it allows for high-fidelity single-photon detection at twice the rate supported by a conventional single-pump up-conversion detector. We also discuss the limiting factors of this approach and identify important performance-limiting trade offs.

Optics Express•Mar 8, 2011•27 citations

Detection and spectral measurement of single photons in communication bands using up-conversion technology

Long Ma, Oliver Slattery, Xiao Hong Tang

Quantum information systems are commonly operated in conventional communication bands (1310 and 1550 nm) over an optical fiber to take advantage of low transmission loss. However, the detection and spectral measurement of single photons in these communication bands are limited due to high noise and low sensitivity of single photon detectors in the wavelength ranges. To demonstrate high efficiency detection and high sensitivity spectral measurement, we have implemented a single photon detector and a spectrometer based on frequency up-conversion technology. This detector and spectrometer uses a 5-cm periodically poled lithium niobate (PPLN) waveguide and a tunable pump laser around 1550 nm, to convert signal photons around 1310 to 710 nm. The converted photons are then detected by a silicon-based avalanche photodiode (APD). The overall detection efficiency of the single photon detector is as high as 32%, which is three times higher than commercial InGaAs APDs. The sensitivity of the spectrometer is measured to be −126 dBm, which is at least three orders-of-magnitude better than any commercial optical spectrum analyzer in this wavelength range.

Laser Physics•Apr 2, 2010•11 citations

Low noise up-conversion single photon detector and its applications in quantum information systems

Lijun Ma, Oliver Slattery, Alan Mink +1 more

We developed low-noise up-conversion single photon detectors for 1310 nm based on a periodically-poled LiNbO3 (PPLN) waveguide. The low-noise feature is achieved by using a pulsed optical pump at a wavelength longer than the signal wavelength. The detectors were used in a quantum key distribution (QKD) systems based on polarization encoding, measurement for entangled photon pairs and spectrum measurement at single photon levels. In this paper, the overall detection efficiency and noise level of the detectors are characterized and the polarization and wavelength sensitivity of the detection efficiency is analyzed. The applications of this detector in quantum information systems are also described.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jul 21, 2009•8 citations

Development of single-photon sources, detectors, spectrometers and interfaces for quantum communication systems

Oliver Slattery

This thesis describes work on single-photon pair creation, entanglement and entanglement measurement; single-photon spectral narrowing for atomic interaction; and single-photon detection and spectral analysis. The systems developed exploit the interactions of light beams in non-linear crystal materials. Greatly non-degenerate time-bin entangled photon pair sources are implemented based on the quantum process of spontaneous-parametric-down-conversion. The non-degenerate wavelengths correspond to an atomic transition (895 nm) and a telecommunications band (1310 nm). Interference-fringe-visibilities of over 78% are achieved, verifying entanglement. An efficient and low-noise single-photon up-conversion detector based on sum-frequency-generation is implemented. Photons at 1310 nm are converted to the visible region and efficiently detected using a visible single-photon detector. An overall detection efficiency of over 32% is achieved with a dark-count noise rate of 2500 s-1. The detector is further developed to achieve an inter-symbol-interference free detection rate at twice the limit of the type of visible detector used. The detector is adapted into an up-conversion spectrometer for wavelengths near 1310 nm. A sensitivity of -126 dBm is achieved, corresponding to photon fluxes of approximately 500 s-1. The up-conversion spectrometer is further adapted for correlated biphoton spectroscopy by incorporating a frequency entangled and time correlated source. In this scheme, the spectral function near 895 nm of a remote object can be reproduced by locally measuring the 1310 nm with the up-conversion spectrometer and monitoring the coincidence detection rates. To achieve linewidths feasible for atomic interaction, a very narrow linewidth non-degenerate single-photon pair source is implemented based on spontaneous-parametric-down-conversion embedded in a singly-resonant cavity which is locked to and resonating at the frequency corresponding to a target atomic transition. Linewidths as narrow as 28 MHz are achieved. The brightness of the source within the modes is increased by two-orders compared to the single-pass implementations.

•Jan 1, 2015•0 citations

Tunable up-conversion detector for single photon and bi-photon infrared spectroscopic applications

Oliver Slattery, Lijun Ma, Paulina S. Kuo +2 more

A tunable waveguide-based frequency up-conversion detector is used for single photon level near infrared (IR) spectroscopic measurements. Applications include direct spectroscopic measurement of week near IR signals and remote bi-photon spectroscopy. We have demonstrated direct spectroscopy of single photon near IR signals from a greatly attenuated laser and a single photon source. We further applied the up-conversion spectrometer for frequency correlated bi-photon spectroscopy using a single photon source of non-degenerate photon pairs at 1310 nm (near IR) and 895 nm. In correlated bi-photon spectroscopy, the spectral function at one wavelength range of a remote object can be reproduced by locally measuring another (near IR) wavelength range using the up-conversion spectrometer and monitoring the coincidence counts. A near IR single photon detection efficiency of 32 % has been achieved with the up-conversion spectrometer. The spectral resolution of the system is approximately 0.2 nm at 1310 nm based on the acceptance width of the up-conversion chip used. In bi-photon spectroscopy, the spectral resolution for the correlated photons at 895 nm is approximately 0.1 nm. The sensitivity achieved using the up-conversion detector is -126 dBm at 1310 nm.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 29, 2013•2 citations
We have studied single photon level frequency up-conversion, and developed efficient single photon detectors and a highly sensitive spectrometer at a telecommunication wavelength (around 1310 nm). We have applied the detector and spectrometer to the implementation of a quantum key distribution system; to the characterization of an entangled photon source and a single photon source from quantum dots; to increase the temporal resolution of the single photon detector; and to study on high-order temporal correlation following frequency conversion. In this paper, we will present an overview on the frequency up-conversion technique and its applications in quantum information systems.
Frequency up-conversion technology can be used to increase detection efficiency for near infrared photons, as has been demonstrated in fiber-based quantum communication systems. In a continuous wave pumped up-conversion detector, the temporal resolution is limited by the timing jitter of the detector in the visible range, which limits the maximum clock rate of a quantum communication system. In this paper we describe a scheme to improve the temporal resolution of an up-conversion single-photon detector using multi-wavelength optical-sampling techniques, allowing for increased transmission rates in single-photon communications systems. We experimentally demonstrate our approach with an up-conversion detector using two spectrally and temporally distinct pump pulses, and show that it allows for high-fidelity single-photon detection at twice the rate supported by a conventional single-pump up-conversion detector.
The maximum achievable data-rate of a quantum communication system can be critically limited by the efficiency and temporal resolution of the system's single-photon detectors. Frequency up-conversion technology can be used to increase detection efficiency for IR photons. In this paper we describe a scheme to improve the temporal resolution of an up-conversion single-photon detector using multi-wavelength optical-sampling techniques, allowing for increased transmission rates in single-photon communications systems. We experimentally demonstrate our approach with an up-conversion detector using two spectrally and temporally distinct pump pulses, and show that it allows for high-fidelity single-photon detection at twice the rate supported by a conventional single-pump up-conversion detector. We also discuss the limiting factors of this approach and identify important performance-limiting trade offs.
Quantum information systems are commonly operated in conventional communication bands (1310 and 1550 nm) over an optical fiber to take advantage of low transmission loss. However, the detection and spectral measurement of single photons in these communication bands are limited due to high noise and low sensitivity of single photon detectors in the wavelength ranges. To demonstrate high efficiency detection and high sensitivity spectral measurement, we have implemented a single photon detector and a spectrometer based on frequency up-conversion technology. This detector and spectrometer uses a 5-cm periodically poled lithium niobate (PPLN) waveguide and a tunable pump laser around 1550 nm, to convert signal photons around 1310 to 710 nm. The converted photons are then detected by a silicon-based avalanche photodiode (APD). The overall detection efficiency of the single photon detector is as high as 32%, which is three times higher than commercial InGaAs APDs. The sensitivity of the spectrometer is measured to be −126 dBm, which is at least three orders-of-magnitude better than any commercial optical spectrum analyzer in this wavelength range.
We developed low-noise up-conversion single photon detectors for 1310 nm based on a periodically-poled LiNbO3 (PPLN) waveguide. The low-noise feature is achieved by using a pulsed optical pump at a wavelength longer than the signal wavelength. The detectors were used in a quantum key distribution (QKD) systems based on polarization encoding, measurement for entangled photon pairs and spectrum measurement at single photon levels. In this paper, the overall detection efficiency and noise level of the detectors are characterized and the polarization and wavelength sensitivity of the detection efficiency is analyzed. The applications of this detector in quantum information systems are also described.
This thesis describes work on single-photon pair creation, entanglement and entanglement measurement; single-photon spectral narrowing for atomic interaction; and single-photon detection and spectral analysis. The systems developed exploit the interactions of light beams in non-linear crystal materials. Greatly non-degenerate time-bin entangled photon pair sources are implemented based on the quantum process of spontaneous-parametric-down-conversion. The non-degenerate wavelengths correspond to an atomic transition (895 nm) and a telecommunications band (1310 nm). Interference-fringe-visibilities of over 78% are achieved, verifying entanglement. An efficient and low-noise single-photon up-conversion detector based on sum-frequency-generation is implemented. Photons at 1310 nm are converted to the visible region and efficiently detected using a visible single-photon detector. An overall detection efficiency of over 32% is achieved with a dark-count noise rate of 2500 s-1. The detector is further developed to achieve an inter-symbol-interference free detection rate at twice the limit of the type of visible detector used. The detector is adapted into an up-conversion spectrometer for wavelengths near 1310 nm. A sensitivity of -126 dBm is achieved, corresponding to photon fluxes of approximately 500 s-1. The up-conversion spectrometer is further adapted for correlated biphoton spectroscopy by incorporating a frequency entangled and time correlated source. In this scheme, the spectral function near 895 nm of a remote object can be reproduced by locally measuring the 1310 nm with the up-conversion spectrometer and monitoring the coincidence detection rates. To achieve linewidths feasible for atomic interaction, a very narrow linewidth non-degenerate single-photon pair source is implemented based on spontaneous-parametric-down-conversion embedded in a singly-resonant cavity which is locked to and resonating at the frequency corresponding to a target atomic transition. Linewidths as narrow as 28 MHz are achieved. The brightness of the source within the modes is increased by two-orders compared to the single-pass implementations.
A tunable waveguide-based frequency up-conversion detector is used for single photon level near infrared (IR) spectroscopic measurements. Applications include direct spectroscopic measurement of week near IR signals and remote bi-photon spectroscopy. We have demonstrated direct spectroscopy of single photon near IR signals from a greatly attenuated laser and a single photon source. We further applied the up-conversion spectrometer for frequency correlated bi-photon spectroscopy using a single photon source of non-degenerate photon pairs at 1310 nm (near IR) and 895 nm. In correlated bi-photon spectroscopy, the spectral function at one wavelength range of a remote object can be reproduced by locally measuring another (near IR) wavelength range using the up-conversion spectrometer and monitoring the coincidence counts. A near IR single photon detection efficiency of 32 % has been achieved with the up-conversion spectrometer. The spectral resolution of the system is approximately 0.2 nm at 1310 nm based on the acceptance width of the up-conversion chip used. In bi-photon spectroscopy, the spectral resolution for the correlated photons at 895 nm is approximately 0.1 nm. The sensitivity achieved using the up-conversion detector is -126 dBm at 1310 nm.