Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Spectral, noise and correlation properties of intense squeezed light generated by a coupling in two laser fields

Gagik Yu. Kryuchkyan, Karen V. Kheruntsyan

Published May 1, 1994• 0 citations
OpenAlex

Abstract

Two schemes of four-wave mixing oscillators with nondegenerate pumps are proposed for above-threehold generation of squeezed light with nonzero mean-field amplitudes. Noise and correlation properties and optical spectra of squeezed-light beams generated in these schemes are discussed.

Related papers

GENERATION OF PULSED SQUEEZED LIGHT FIELD VIA FORWARD FOUR-WAVE MIXING

Lin-sheng He, JIANG HAI-HE, XIA YU-XING +1 more

A scheme is proposed, in which the pulse train of squeezed light is generated via forward four-wave mixing through a nonlinear medium with third-order polarizability, coherently pumped by a train of pulses of modelocked laser. One of the quadrature noise compoments of the squeezed light is measured with a balanced homodyne detector using a pulse train as the local oscillation. The theoretical results show that the fairly high-intensity output of squeezed light can be achieved, and the noise-power spectrum of the light is almost completely squeezed and exhibits the form of a train of pulses, but the shape of squeezed spectrum is reversed with respect to that of the pulse train of the input light.

Acta Physica Sinica•Jan 1, 1991•1 citation

Squeezed states in nondegenerate four-wave mixing

David A. Holm, Murray Sargent

Our quantum theory of multiwave mixing1 treats the interactions between one or two classical pump fields with one or two quantized fields in two-level media. It unifies a number of areas of quantum optics, such as resonance fluorescence, saturation spectroscopy, laser instabilities, and phase conjugation. This paper applies the theory to the generation of squeezed states of light.

•Jun 9, 1986•0 citations

Squeezing Property of Two-mode Cavity Field in a Nondegenerate Four-wave Mixing System

Wenwu Deng

We apply nondegenerate four-wave mixing processes to the generation of squeezed light and study the evolution of squeezed light with time.We get the master equation of the two-mode field.We also show that the two-mode cavity field exhibits stable squeezing under some conditions.The degree of the squeezing is dependent upon the two photon intensity I2,the cooperativity parameter C and the side-mode detuning.

湖北科技学院学报•Jan 1, 2008•0 citations

Squeezed states: an overview

Bernard Yurke

A squeezed state of the electromagnetic field has less noise in one of its two amplitude components than that of a coherent state. This property makes squeezed states potentially useful in low noise and precision measurement. Squeezed states may be generated by, among other things, degenerate parametric amplifiers and four-wave mixers. The reduced noise in one of the amplitude components is most easily observed via a homodyne detector. A number of experimental efforts to generate and detect squeezed states are under way. Here, in describing experimental techniques, the experiments' carried out by Slusher et al. are emphasized. A number of techniques were employed to successfully generate squeezed light. An atomic beam of sodium provided the optical nonlinearity in a cavity-backward four-wave mixer. By employing pairs of Fabry-Perot modes spaced symmetrically about the pump frequency, squeezed light was generated in nondegenerate conditions where Rayleigh scattering of pump light could be avoided. To observe squeezing, a number of nonidealities such as phase jitter and detector inefficiencies also had to be overcome.

Annual Meeting Optical Society of America•Jan 1, 1986•0 citations

Four-mode squeezing

Bonny L. Schumaker, Stephen H. Perlmutter, Robert M. Shelby +1 more

The four-wave-mixing interactions produced by pumping at two well-separated frequencies can couple four different radiation modes to generate a new kind of squeezed state of light. A dual-frequency homodyne detection scheme is described and is used to observe this type of nonclassical correlation. Initial experimental results in an optical fiber show a noise level 20% below the vacuum noise level for the output of the dual-frequency detector, even though the noise at each individual detector remains above the vacuum level.

Physical Review Letters•Jan 26, 1987•76 citations

Optical four-wave mixing and generation of squeezed light in an optomechanical cavity driven by a bichromatic field

Rafael Garcés, Germán J. de Valcárcel

We show that an optomechanical cavity pumped by a bichromatic light beam can generate a signal whose frequency lies halfway between the two driving frequencies. This process can be understood as a degenerate four-wave mixing, in which two pump photons (one from each frequency) are combined to yield two identical signal photons. This process takes place between a lower and an upper threshold in terms of the pump intensity, which depend on the pump frequency difference. Close to the signal oscillation threshold a clear noise reduction in one of its quadratures is shown numerically.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 1, 2014•1 citation
A scheme is proposed, in which the pulse train of squeezed light is generated via forward four-wave mixing through a nonlinear medium with third-order polarizability, coherently pumped by a train of pulses of modelocked laser. One of the quadrature noise compoments of the squeezed light is measured with a balanced homodyne detector using a pulse train as the local oscillation. The theoretical results show that the fairly high-intensity output of squeezed light can be achieved, and the noise-power spectrum of the light is almost completely squeezed and exhibits the form of a train of pulses, but the shape of squeezed spectrum is reversed with respect to that of the pulse train of the input light.
A squeezed state of the electromagnetic field has less noise in one of its two amplitude components than that of a coherent state. This property makes squeezed states potentially useful in low noise and precision measurement. Squeezed states may be generated by, among other things, degenerate parametric amplifiers and four-wave mixers. The reduced noise in one of the amplitude components is most easily observed via a homodyne detector. A number of experimental efforts to generate and detect squeezed states are under way. Here, in describing experimental techniques, the experiments' carried out by Slusher et al. are emphasized. A number of techniques were employed to successfully generate squeezed light. An atomic beam of sodium provided the optical nonlinearity in a cavity-backward four-wave mixer. By employing pairs of Fabry-Perot modes spaced symmetrically about the pump frequency, squeezed light was generated in nondegenerate conditions where Rayleigh scattering of pump light could be avoided. To observe squeezing, a number of nonidealities such as phase jitter and detector inefficiencies also had to be overcome.
The four-wave-mixing interactions produced by pumping at two well-separated frequencies can couple four different radiation modes to generate a new kind of squeezed state of light. A dual-frequency homodyne detection scheme is described and is used to observe this type of nonclassical correlation. Initial experimental results in an optical fiber show a noise level 20% below the vacuum noise level for the output of the dual-frequency detector, even though the noise at each individual detector remains above the vacuum level.
We show that an optomechanical cavity pumped by a bichromatic light beam can generate a signal whose frequency lies halfway between the two driving frequencies. This process can be understood as a degenerate four-wave mixing, in which two pump photons (one from each frequency) are combined to yield two identical signal photons. This process takes place between a lower and an upper threshold in terms of the pump intensity, which depend on the pump frequency difference. Close to the signal oscillation threshold a clear noise reduction in one of its quadratures is shown numerically.