Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics and Spectroscopy

Suppression of light amplitude noise by two-photon absorption in an external cavity

В. Н. Горбачев, A. S. Troshin, Andrew I. Trubilko

Published Mar 1, 1992• 0 citations
OpenAlex

Related papers

Broadband noise suppression in light propagating through a multiphoton absorber

В. Н. Горбачев, A. A. Trubilko, J. George Adashko

Journal of Experimental and Theoretical Physics•Nov 1, 1992•0 citations

Understanding the sensitivity of cavity-enhanced absorption spectroscopy: pathlength enhancement versus noise suppression

Bin Ouyang, Roderic L. Jones

Cavity-enhanced absorption spectroscopy is now widely used as an ultrasensitive technique in observing weak spectroscopic absorptions. Photons inside the cavity are reflected back and forth between the mirrors with reflectivities R close to one and thus (on average) exploit an absorption pathlength L that is 1/(1 − R ) longer than a single pass measurement. As suggested by the Beer-Lambert law, this increase in L results in enhanced absorbance A (given by αL with α being the absorption coefficient) which in turn favours the detection of weak absorptions. At the same time, however, only (1 − R ) of the incident light can enter the cavity [assuming that mirror transmission T is equal to (1 − R )], so that the reduction in transmitted light intensity Δ I caused by molecular absorption equates to that would be obtained if in fact no cavity were present . The enhancement in A = Δ I / I , where I is the total transmitted light intensity, achievable from CEAS therefore comes not from an increase in Δ I , but a sharp decrease in I. In this paper, we calculate the magnitudes of these two terms before and after a cavity is introduced, and aim at interpreting the sensitivity improvement offered by cavity-enhanced absorption spectroscopy from this observable-oriented (i.e. Δ I and I ) perspective. It is first shown that photon energy stored in the cavity is at best as intense as the input light source, implying that any absorbing sample within the cavity is exposed to the same or even lower light intensity after the cavity is formed. As a consequence, the intensity of the light absorbed or scattered by the sample, which corresponds to the Δ I term aforementioned, is never greater than would be the case in a single pass measurement. It is then shown that while this “numerator” term is not improved, the “denominator” term, I , is reduced considerably; therefore, the increase in contrast ratio Δ I / I is solely contributed by the attenuation of transmitted background light I and is ultimately down to the suppression of any measurement noise that is associated with it. The noise component that is most effectively suppressed is the type whose magnitude scales linearly with light intensity I , as is typical of noise caused by environmental instabilities, followed by the shot noise which scales as square root of I . No suppression is achievable for noise sources that are independent of I , a notable example being the thermal noise of a detector or of detection electronics. The usefulness of this “noise suppression” argument is that it links the sensitivity gain offered by a cavity with the property of measurement noise present in the system, and clearly suggests that the achievable sensitivity is dependent on how efficient the various noise components are “suppressed” by the cavity.

Applied Physics B•Sep 17, 2012•30 citations

Two-Photon Transparency and Absorption Enhancement

Suhui Yang, Dong Wang, Xu-Zhen Guo +2 more

European Quantum Electronics Conference (EQEC)•Aug 24, 2005•0 citations

Magnetically controlled optical modulator based on coherent perfect absorption in NV centers

Ming-feng Jiao, Chang-Shui Yu

We design an optical modulator based on an optical resonant cavity that coherently couples to an ensemble of nitrogen-vacancy (NV) centers, controlled by an external magnetic field. We reveal the coherent perfect absorption (CPA) of photons in the system and demonstrate how to suppress, block, and amplify light transmission by manipulating the amplitude, direction, and detuning of the external magnetic field, as well as the phase difference between the input light fields. This design leverages the friendly controllability of NV centers by an external magnetic field, suggesting the potential to develop advanced photonic devices.

Optics Letters•May 6, 2026•0 citations

Intensity noise reduction in light by photon control

A. Heidmann, Jerome C. Mertz, Claude Fabre +2 more

Quantum Electronics and Laser Science Conference•May 10, 1992•0 citations

Two photon absorption with coherent and partially coherent driving fields

S. Chaturvedi, P. D. Drummond, Daniel F. Walls

A model of two photon absorption in a cavity with an external driving field is presented. Phase and amplitude fluctuations in the driving field are taken into account to model a partially coherent multimode source. The photon statistics of the light in the cavity are investigated through a calculation of the second-order correlation function of the light field in the steady state. For a coherent driving field the field inside the cavity will exhibit photon antibunching for low intensities. As the fluctuations in the driving field are increased the photon antibunching is lost. For a particular coherent field, g (2) (0) is reduced with increasing laser intensity. This reduction with laser intensity is slower with increasing laser amplitude fluctuations. This could provide a possible explanation for the recent experimental observations of Kransinski and Dinev (1976).

Journal of Physics A Mathematical and General•Nov 1, 1977•66 citations
Cavity-enhanced absorption spectroscopy is now widely used as an ultrasensitive technique in observing weak spectroscopic absorptions. Photons inside the cavity are reflected back and forth between the mirrors with reflectivities R close to one and thus (on average) exploit an absorption pathlength L that is 1/(1 − R ) longer than a single pass measurement. As suggested by the Beer-Lambert law, this increase in L results in enhanced absorbance A (given by αL with α being the absorption coefficient) which in turn favours the detection of weak absorptions. At the same time, however, only (1 − R ) of the incident light can enter the cavity [assuming that mirror transmission T is equal to (1 − R )], so that the reduction in transmitted light intensity Δ I caused by molecular absorption equates to that would be obtained if in fact no cavity were present . The enhancement in A = Δ I / I , where I is the total transmitted light intensity, achievable from CEAS therefore comes not from an increase in Δ I , but a sharp decrease in I. In this paper, we calculate the magnitudes of these two terms before and after a cavity is introduced, and aim at interpreting the sensitivity improvement offered by cavity-enhanced absorption spectroscopy from this observable-oriented (i.e. Δ I and I ) perspective. It is first shown that photon energy stored in the cavity is at best as intense as the input light source, implying that any absorbing sample within the cavity is exposed to the same or even lower light intensity after the cavity is formed. As a consequence, the intensity of the light absorbed or scattered by the sample, which corresponds to the Δ I term aforementioned, is never greater than would be the case in a single pass measurement. It is then shown that while this “numerator” term is not improved, the “denominator” term, I , is reduced considerably; therefore, the increase in contrast ratio Δ I / I is solely contributed by the attenuation of transmitted background light I and is ultimately down to the suppression of any measurement noise that is associated with it. The noise component that is most effectively suppressed is the type whose magnitude scales linearly with light intensity I , as is typical of noise caused by environmental instabilities, followed by the shot noise which scales as square root of I . No suppression is achievable for noise sources that are independent of I , a notable example being the thermal noise of a detector or of detection electronics. The usefulness of this “noise suppression” argument is that it links the sensitivity gain offered by a cavity with the property of measurement noise present in the system, and clearly suggests that the achievable sensitivity is dependent on how efficient the various noise components are “suppressed” by the cavity.
We design an optical modulator based on an optical resonant cavity that coherently couples to an ensemble of nitrogen-vacancy (NV) centers, controlled by an external magnetic field. We reveal the coherent perfect absorption (CPA) of photons in the system and demonstrate how to suppress, block, and amplify light transmission by manipulating the amplitude, direction, and detuning of the external magnetic field, as well as the phase difference between the input light fields. This design leverages the friendly controllability of NV centers by an external magnetic field, suggesting the potential to develop advanced photonic devices.
A model of two photon absorption in a cavity with an external driving field is presented. Phase and amplitude fluctuations in the driving field are taken into account to model a partially coherent multimode source. The photon statistics of the light in the cavity are investigated through a calculation of the second-order correlation function of the light field in the steady state. For a coherent driving field the field inside the cavity will exhibit photon antibunching for low intensities. As the fluctuations in the driving field are increased the photon antibunching is lost. For a particular coherent field, g (2) (0) is reduced with increasing laser intensity. This reduction with laser intensity is slower with increasing laser amplitude fluctuations. This could provide a possible explanation for the recent experimental observations of Kransinski and Dinev (1976).