Conference on Precision Electromagnetic Measurements

Very-high Q microwave resonances in trapped /sup 171/Yb/sup +/ ions: application as a microwave frequency standard

Peter Fisk, M.A. Lawn, C. Coles, Anthony G. Mann, D. G. Blair

Published Dec 17, 2002• 0 citations
Publisher

Abstract

The 12.6 GHz microwave resonance in /sup 171/Yb/sup +/ ions confined in a linear Paul trap is interrogated using a cryogenic sapphire resonator-based microwave source. Line Q factors of up to 1.1/spl times/10/sup 13/ have been observed. We report on the performance of the ion trap-sapphire resonator system as a prototype 12.6 GHz frequency standard.>

DOI
10.1109/cpem.1994.333303

Related papers

Very high Q microwave spectroscopy on trapped /sup 171/Yb/sup +/ ions: application as a frequency standard

Peter Fisk, Matthew J. Sellars, M.A. Lawn +3 more

A microwave frequency standard based on buffer-gas cooled /sup 171/Yb/sup +/ ions confined in a linear Paul trap has been demonstrated in prototype form. The standard exhibits a fractional frequency instability characterized by an Allan deviation /spl sigma//sub y/(/spl tau/)=3.7/spl times/10/sup -13//spl tau//sup -1/2/ for /spl tau/>

IEEE Transactions on Instrumentation and Measurement•Apr 1, 1995•45 citations

Performance of a prototype microwave frequency standard based on trapped /sup 171/Yb/sup +/ ions

Peter Fisk, Matthew J. Sellars, M.A. Lawn +3 more

A microwave frequency standard based on buffer-gas cooled /sup 171/Yb/sup +/ ions confined in a linear Paul trap has been demonstrated in prototype form. The standard exhibits a fractional Allan deviation /spl sigma//sub y/(/spl tau/)=3.7/spl times/10/sup -13/ /spl tau//sup -1/2/ for /spl tau/>

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Dec 17, 2002•5 citations

Progress at CSIRO Australia towards a microwave frequency standard based on trapped, laser-cooled /sup 171/Yb/sup +/ ions

Peter Fisk, M.A. Lawn, C. Coles

The authors report preliminary results of precision microwave-optical double resonance spectroscopy on buffer gas cooled /sup 171/Yb/sup +/ ions confined in a linear Paul trap as a microwave frequency standard at 12.6 GHz. They also report laser cooling of trapped /sup 171/Yb/sup +/ ions. Temperatures below 1 K have been achieved, and evidence for a phase transition to a crystal-like state has been found. This temperature is sufficiently low to reduce the fractional second-order Doppler shift of the microwave resonance to below 10/sup -14/.>

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Dec 30, 2002•1 citation

A microwave frequency standard based on laser-cooled /sup 171/Yb/sup +/ ions

Richard B. Warrington, Peter Fisk, Michael J. Wouters +1 more

We report operation of a microwave frequency standard based on the 12.6 GHz ground-state hyperfine transition in a cloud of laser-cooled /sup 171/Yb/sup +/ ions. The projected performance of this standard (frequency uncertainty /spl les/ 4 /spl times/ 10/sup -15/ and stability 5 /spl times/ 10/sup -14/ /spl tau//sup -1/2/ for a 10 s Ramsey time) is comparable to that of a cesium fountain.

Conference on Precision Electromagnetic Measurements•Jun 25, 2003•0 citations

Progress on a cryogenic linear trap for /sup 199/Hg/sup +/ ions

Martin E. Poitzsch, T.J.C. Bergquist, Wayne M. Itano +1 more

We have observed linear "crystals" of up to tens of laser-cooled /sup 199/Hg/sup +/ ions in a new cryogenic linear rf ion trap that operates at liquid helium temperature and is designed for use as a prototype 40.5 GHz frequency standard with high accuracy and stability.>

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Dec 17, 2002•1 citation

Progress toward a cryogenic /sup 199/Hg/sup +/ ion frequency standard

Martin E. Poitzsch, Jonas Bergquist, Wayne M. Itano +1 more

We have observed linear "crystals" of up to tens of laser-cooled /sup 199/Hg/sup +/ ions in a new cryogenic linear rf ion trap that operates at liquid helium temperature and is designed for use as a prototype 40.5 GHz frequency standard with high accuracy and stability.>

Conference on Precision Electromagnetic Measurements•Dec 17, 2002•0 citations
The 12.6 GHz microwave resonance in /sup 171/Yb/sup +/ ions confined in a linear Paul trap is interrogated using a cryogenic sapphire resonator-based microwave source. Line Q factors of up to 1.1/spl times/10/sup 13/ have been observed. We report on the performance of the ion trap-sapphire resonator system as a prototype 12.6 GHz frequency standard.>
The authors report preliminary results of precision microwave-optical double resonance spectroscopy on buffer gas cooled /sup 171/Yb/sup +/ ions confined in a linear Paul trap as a microwave frequency standard at 12.6 GHz. They also report laser cooling of trapped /sup 171/Yb/sup +/ ions. Temperatures below 1 K have been achieved, and evidence for a phase transition to a crystal-like state has been found. This temperature is sufficiently low to reduce the fractional second-order Doppler shift of the microwave resonance to below 10/sup -14/.>