Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Progress on a cryogenic linear trap for /sup 199/Hg/sup +/ ions

Martin E. Poitzsch, T.J.C. Bergquist, Wayne M. Itano, D. J. Wineland

Published Dec 17, 2002• 1 citation
Publisher

Abstract

We have observed linear "crystals" of up to tens of laser-cooled /sup 199/Hg/sup +/ ions in a new cryogenic linear rf ion trap that operates at liquid helium temperature and is designed for use as a prototype 40.5 GHz frequency standard with high accuracy and stability.>
DOI
10.1109/freq.1994.398253

Related papers

Progress toward a cryogenic /sup 199/Hg/sup +/ ion frequency standard

Martin E. Poitzsch, Jonas Bergquist, Wayne M. Itano +1 more

We have observed linear "crystals" of up to tens of laser-cooled /sup 199/Hg/sup +/ ions in a new cryogenic linear rf ion trap that operates at liquid helium temperature and is designed for use as a prototype 40.5 GHz frequency standard with high accuracy and stability.>

Conference on Precision Electromagnetic Measurements•Dec 17, 2002•0 citations

Cryogenic linear ion trap for accurate spectroscopy

Martin E. Poitzsch, Jonas Bergquist, Wayne M. Itano +1 more

We have observed linear ‘‘crystals’’ of up to tens of laser-cooled 199Hg+ ions in a linear rf ion trap. The trap operates at liquid-He temperature and is designed for use as a prototype 40.5 GHz frequency standard with high accuracy and stability.

Review of Scientific Instruments•Jan 1, 1996•66 citations

A cryogenic linear ion trap for /sup 199/Hg/sup +/ frequency standards

J.D. Miller, M.E. Poitzsch, Flávio C. Cruz +4 more

A cryogenic linear rf trap has been constructed to study the accuracy of a clock based on laser cooled /sup 199/Hg/sup +/. Crystals of tens of ions have been observed. The residual micromotion of the ions has been minimized and Ramsey interrogation periods of 25 s have been demonstrated for the 40.5 GHz transition. This system should eventually provide a frequency standard of high precision and accuracy. We report on the development of compact, efficient, solid-state sources at 194 nm and 282 nm for laser cooling of /sup 199/Hg/sup +/ and investigation of the /sup 2/S/sub 1/2//spl rarr//sup 2/D/sub 5/2/ quadrupole transition of interest for an optical frequency standard.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Nov 19, 2002•0 citations

A cryogenic linear ion trap for /sup 199/Hg/sup +/ frequency standards

J.D. Miller, Dana J. Berkeland, Flávio C. Cruz +3 more

A cryogenic linear rf trap has been constructed to study the accuracy of a clock based on laser cooled /sup 199/Hg/sup +/. Crystals of tens of ions have been observed. The residual micromotion of the ions has been minimized and Ramsey interrogation periods of 100 s have been demonstrated for the 40.5 GHz transition. Systematic shifts to the clock transition due to magnetic field fluctuations as well as heating of the ions during the clock cycle have been evaluated. This system should eventually provide a frequency standard of high precision and accuracy.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Dec 23, 2002•0 citations

Laser-microwave double resonance frequency standard using {sup 199}Hg{sup +} ions in a cryogenic linear trap

Martin E. Poitzsch, Jonas Bergquist, W. M. Itano +1 more

We have previously reported experiments using a linear rf trap to store laser-cooled {sup 199}Hg{sup +} ions. Trapping multiple ions increases the signal-to-noise ratio; yet all ions have equally low second-order Doppler shifts if they are confined along the nodal center line of a linear trap. In such an environment, the 40.5 GHz ground-state hyperfine transition in {sup 199}Hg{sup +} is a candidate for an extremely accurate and stable microwave frequency standard. Our redesigned apparatus will operate at cryogenic temperatures to provide very low background gas pressure (resulting in longer ion storage times and immunity from background pressure shifts) and superconductive shielding against stray magnetic fields. We shall discuss progress on this frequency standard and applications of our apparatus to new cooling and squeezing techniques.

Bulletin of the American Physical Society•May 1, 1993•0 citations

/sup 199/Hg/sup +/ optical frequency standard: progress report

Robert J. Rafac, Brent C. Young, Flávio C. Cruz +4 more

We are developing an optical frequency standard based on the narrow /sup 2/S/sub 1/2/-/sup 2/D/sub 5/2/ electric-quadrupole transition of a single trapped /sup 199/Hg/sup +/ ion. Small linear traps designed to operate at liquid helium temperatures have been constructed which will provide confinement in the Lamb-Dicke regime for the optical transition. Cryogenic operation yields long ion storage times and significantly suppresses frequency shifts due to collisions and blackbody radiation. A major step toward the completion of this standard has been the construction and evaluation of a well isolated, high-finesse, Fabry-Perot cavity to stabilize the frequency of the interrogating laser. We report our cavity results and progress toward locking the laser frequency to the transition in the stored ion.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jan 22, 2003•2 citations
A cryogenic linear rf trap has been constructed to study the accuracy of a clock based on laser cooled /sup 199/Hg/sup +/. Crystals of tens of ions have been observed. The residual micromotion of the ions has been minimized and Ramsey interrogation periods of 25 s have been demonstrated for the 40.5 GHz transition. This system should eventually provide a frequency standard of high precision and accuracy. We report on the development of compact, efficient, solid-state sources at 194 nm and 282 nm for laser cooling of /sup 199/Hg/sup +/ and investigation of the /sup 2/S/sub 1/2//spl rarr//sup 2/D/sub 5/2/ quadrupole transition of interest for an optical frequency standard.
A cryogenic linear rf trap has been constructed to study the accuracy of a clock based on laser cooled /sup 199/Hg/sup +/. Crystals of tens of ions have been observed. The residual micromotion of the ions has been minimized and Ramsey interrogation periods of 100 s have been demonstrated for the 40.5 GHz transition. Systematic shifts to the clock transition due to magnetic field fluctuations as well as heating of the ions during the clock cycle have been evaluated. This system should eventually provide a frequency standard of high precision and accuracy.
We have previously reported experiments using a linear rf trap to store laser-cooled {sup 199}Hg{sup +} ions. Trapping multiple ions increases the signal-to-noise ratio; yet all ions have equally low second-order Doppler shifts if they are confined along the nodal center line of a linear trap. In such an environment, the 40.5 GHz ground-state hyperfine transition in {sup 199}Hg{sup +} is a candidate for an extremely accurate and stable microwave frequency standard. Our redesigned apparatus will operate at cryogenic temperatures to provide very low background gas pressure (resulting in longer ion storage times and immunity from background pressure shifts) and superconductive shielding against stray magnetic fields. We shall discuss progress on this frequency standard and applications of our apparatus to new cooling and squeezing techniques.
We are developing an optical frequency standard based on the narrow /sup 2/S/sub 1/2/-/sup 2/D/sub 5/2/ electric-quadrupole transition of a single trapped /sup 199/Hg/sup +/ ion. Small linear traps designed to operate at liquid helium temperatures have been constructed which will provide confinement in the Lamb-Dicke regime for the optical transition. Cryogenic operation yields long ion storage times and significantly suppresses frequency shifts due to collisions and blackbody radiation. A major step toward the completion of this standard has been the construction and evaluation of a well isolated, high-finesse, Fabry-Perot cavity to stabilize the frequency of the interrogating laser. We report our cavity results and progress toward locking the laser frequency to the transition in the stored ion.