Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Precision Electromagnetic Measurements

Precision frequency measurement of the clock transition in a Sr/sup +/ single atom with an ultra-stable diode laser

L. Marmet, Alan A. Madej, Klaus J. Siemsen, J. E. Bernard

Published Dec 23, 2002• 0 citations
Publisher

Abstract

We are studying a single Sr/sup +/ atom confined in a Paul trap to produce a frequency standard in the visible region of the spectrum. The goal is to excite a clock transition of the ion at 674 nm with a diode laser and measure its absolute frequency. It is only possible to probe the 0.3-Hz transition if the diode laser is extremely stable during the measurement process which in this experiment can take several minutes to complete. Frequency stabilization of the probing laser was achieved with a lock to an ultra-stable Fabry-Perot cavity. The cavity was temperature stabilized and has demonstrated good long term stability.

DOI
10.1109/cpem.1996.547331

Related papers

Precision interferometric frequency measurement of the 674 nm /sup 2/S/sub 1/2/-/sup 2/D/sub 5/2/ transition in a single cold Sr/sup +/ ion

G. P. Barwood, C.S. Edwards, P. Gill +3 more

The narrow linewidth 674 nm /sup 2/S/sub 1/2/-/sup 2/D/sub 5/2/ transition in a cold Sr/sup +/ ion confined within an rf Paul trap has been probed using an optically-narrowed 674 nm diode laser, offset-locked to a second diode laser stabilised to a high finesse low-expansion reference cavity. A preliminary interferometric frequency measurement of the /sup 2/S/sub 1/2/-/sup 2/D/sub 5/2/ transition will be presented.>

Conference on Precision Electromagnetic Measurements•Dec 17, 2002•0 citations

Indium single ion optical frequency standard

T. Becker, M. Eichenseer, Alexander Yu. Nevsky +5 more

A single laser cooled ion in a radiofrequency trap can serve as the basis for a highly stable optical frequency standard. We present recent results of our work on single indium ions, using the /sup 1/S/sub 0/ to /sup 3/P/sub 0/ transition at 236.5 nm wave-length as the clock transition. This resonance has a linewidth of only 0.82 Hz where systematic shifts should be controllable on the mHz level. A single In/sup +/ ion is stored in a miniature Paul-Straubel trap and laser cooled to a temperature of about 100 /spl mu/K. The clock transition is excited using a frequency quadrupled Nd:YAG laser. A fractional resolution of 1.3/spl middot/10/sup -13/ has been achieved so far (linewidth of 170 Hz at 1267 THz). The absolute frequency of the clock transition clock transition has been measured with an uncertainty of 2/spl middot/10/sup -13/ using a frequency chain and a methane-stabilized HeNe laser as a reference, that was calibrated with a cesium clock.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Nov 13, 2002•3 citations

Clearly resolved secular sidebands on the /sup 2/S/sub 1/2/-/sup 2/D/sub 5/2/ 674-nm clock transition in a single trapped Sr/sup +/ ion

G. P. Barwood, P. Gill, Hugh A. Klein +1 more

A prestabilized 674-nm diode laser has been narrowed by locking it to a high-finesse ultra-low-expansion cavity and kilohertz error signals have been observed. Lamb-Dicke confinement of single laser cooled Sr/sup +/ ions in a miniature rf trap has been demonstrated and micromotion reduction achieved. RF trap sidebands have been observed on the Sr/sup + 2/S/sub 1/2/-/sup 2/D/sub 5/2/ 674 mm clock transition. The transition frequency has been measured to be (444779043.98/spl plusmn/0.12) MHz (2/spl sigma/).

IEEE Transactions on Instrumentation and Measurement•Apr 1, 1997•33 citations

Clearly resolved secular sidebands on the /sup 2/S/sub 1/2/-/sup 2/D/sub 5/2/ 674 nm clock transition in a single trapped Sr/sup +/ ion, and prospects for trapped ion frequency standards

G. P. Barwood, P. Gill, Hugh A. Klein +1 more

A pre-stabilised 674 nm diode laser has been narrowed by locking it to a high-finesse ULE cavity and kHz error signals have been observed. Confinement of single laser cooled Sr/sup +/ ions in a miniature RF trap has been demonstrated and micromotion reduction achieved. RF trap secular sidebands have been observed on the Sr/sup +2/S/sub 1/2/-/sup 2/D/sub 5/2/ 674 nm clock transition. The implication of these results, and similar results in other trapped ion systems will be discussed.

Conference on Precision Electromagnetic Measurements•Dec 23, 2002•0 citations

HIGH RESOLUTION SPECTROSCOPY OF A SINGLE In + ION

Th. Becker, M. Eichenseer, Alexander Yu. Nevsky +5 more

A single laser cooled ion in a radiofrequency trap can serve as a reference for a highly stable optical frequency standard. We present recent results of our work with single indium ions, using the 5 s 2 1 S 0 - 5 s 5 p 3 P 0 transition at a wavelength of 237 nm as the clock transition. This resonance has a linewidth of only 0.8 Hz where systematic shifts should be controllable at the mHz level. A single In + ion is stored in a miniature Paul-Straubel trap and laser cooled to a temperature of about 100 µK. The clock transition is excited using a frequency quadrupled Nd:YAG laser emitting at 946 nm. A fractional resolution of 1.3 × 10 -13 has been achieved so far (linewidth of 170 Hz at 1267 THz), limited by the frequency instability of the Nd :YAG laser. The absolute frequency of the clock transition has been measured with an uncertainty of 2 × 10 -13 using a phase-coherent frequency chain and a methane-stabilized HeNe laser as a reference, that was calibrated against an atomic cesium fountain clock.

Symposium on Frequency Standards and Metrology•May 1, 2002•1 citation

SPECTROSCOPY AND PRECISION FREQUENCY MEASUREMENT OF THE 435.5 nm CLOCK TRANSITION OF 171 Yb +

Chr. Tamm, T. Schneider, E. Peik

We describe experimental investigations on an optical frequency standard based on a single laser cooled 171 Yb + ion confined in a radiofrequency Paul trap. The electric-quadrupole transition from the 2 S 1/2 ( F = 0) ground state to the 2 D 3/2 ( F = 2) state is used as the reference transition. Its wavelength is 435.5 nm and its natural linewidth is 3.1 Hz. The transition is probed using a diode laser system whose short-term frequency stability is derived from an environmentally isolated ULE cavity. The transition is resolved with a Fourier-limited full halfwidth of approximately 30 Hz. The absolute optical transition frequency was determined using a femtosecond frequency comb generator and a Cs fountain clock as the frequency reference. The measured frequency value is 688 358 979 309 312 Hz at an ambient blackbody radiation field of 300 K. The 1σ fractional uncertainty of this frequency measurement is 1 · 10 -14 .

Symposium on Frequency Standards and Metrology•May 1, 2002•5 citations
We are studying a single Sr/sup +/ atom confined in a Paul trap to produce a frequency standard in the visible region of the spectrum. The goal is to excite a clock transition of the ion at 674 nm with a diode laser and measure its absolute frequency. It is only possible to probe the 0.3-Hz transition if the diode laser is extremely stable during the measurement process which in this experiment can take several minutes to complete. Frequency stabilization of the probing laser was achieved with a lock to an ultra-stable Fabry-Perot cavity. The cavity was temperature stabilized and has demonstrated good long term stability.
A single laser cooled ion in a radiofrequency trap can serve as the basis for a highly stable optical frequency standard. We present recent results of our work on single indium ions, using the /sup 1/S/sub 0/ to /sup 3/P/sub 0/ transition at 236.5 nm wave-length as the clock transition. This resonance has a linewidth of only 0.82 Hz where systematic shifts should be controllable on the mHz level. A single In/sup +/ ion is stored in a miniature Paul-Straubel trap and laser cooled to a temperature of about 100 /spl mu/K. The clock transition is excited using a frequency quadrupled Nd:YAG laser. A fractional resolution of 1.3/spl middot/10/sup -13/ has been achieved so far (linewidth of 170 Hz at 1267 THz). The absolute frequency of the clock transition clock transition has been measured with an uncertainty of 2/spl middot/10/sup -13/ using a frequency chain and a methane-stabilized HeNe laser as a reference, that was calibrated with a cesium clock.
A prestabilized 674-nm diode laser has been narrowed by locking it to a high-finesse ultra-low-expansion cavity and kilohertz error signals have been observed. Lamb-Dicke confinement of single laser cooled Sr/sup +/ ions in a miniature rf trap has been demonstrated and micromotion reduction achieved. RF trap sidebands have been observed on the Sr/sup + 2/S/sub 1/2/-/sup 2/D/sub 5/2/ 674 mm clock transition. The transition frequency has been measured to be (444779043.98/spl plusmn/0.12) MHz (2/spl sigma/).
A single laser cooled ion in a radiofrequency trap can serve as a reference for a highly stable optical frequency standard. We present recent results of our work with single indium ions, using the 5 s 2 1 S 0 - 5 s 5 p 3 P 0 transition at a wavelength of 237 nm as the clock transition. This resonance has a linewidth of only 0.8 Hz where systematic shifts should be controllable at the mHz level. A single In + ion is stored in a miniature Paul-Straubel trap and laser cooled to a temperature of about 100 µK. The clock transition is excited using a frequency quadrupled Nd:YAG laser emitting at 946 nm. A fractional resolution of 1.3 × 10 -13 has been achieved so far (linewidth of 170 Hz at 1267 THz), limited by the frequency instability of the Nd :YAG laser. The absolute frequency of the clock transition has been measured with an uncertainty of 2 × 10 -13 using a phase-coherent frequency chain and a methane-stabilized HeNe laser as a reference, that was calibrated against an atomic cesium fountain clock.
We describe experimental investigations on an optical frequency standard based on a single laser cooled 171 Yb + ion confined in a radiofrequency Paul trap. The electric-quadrupole transition from the 2 S 1/2 ( F = 0) ground state to the 2 D 3/2 ( F = 2) state is used as the reference transition. Its wavelength is 435.5 nm and its natural linewidth is 3.1 Hz. The transition is probed using a diode laser system whose short-term frequency stability is derived from an environmentally isolated ULE cavity. The transition is resolved with a Fourier-limited full halfwidth of approximately 30 Hz. The absolute optical transition frequency was determined using a femtosecond frequency comb generator and a Cs fountain clock as the frequency reference. The measured frequency value is 688 358 979 309 312 Hz at an ambient blackbody radiation field of 300 K. The 1σ fractional uncertainty of this frequency measurement is 1 · 10 -14 .