Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Springer eBooks

Photon Noise Reduction in Light Sources

Miguel Orszag, J. C. Retamal

Published Jan 1, 1991• 0 citations
Publisher
DOI
10.1007/978-94-011-3442-2_17

Related papers

Intensity noise reduction in light by photon control

A. Heidmann, Jerome C. Mertz, Claude Fabre +2 more

Quantum Electronics and Laser Science Conference•May 10, 1992•0 citations

Reduction of quantum noise in transmittance estimation using photon-correlated beams

Majeed M. Hayat, Adel Joobeur, Bahaa E. A. Saleh

The accuracy of optical measurements at low light levels is limited by the quantum noise of the source and by the random nature of the interaction with the measured object. The source noise may be reduced by use of nonclassical photon-number squeezed light. We consider the use of two photon-correlated beams (generated, for example, by spontaneous parametric downconversion) to measure the optical transmittance of an object. The photons of each beam obey a random Poisson process but are synchronized in time. One beam is used to probe the object, and the other is used as a reference providing information on the realization of the random arrival of photons at the object. The additional information available by such measurement may be exploited to improve the accuracy of the measurement. Various estimators, including the maximum-likelihood estimator, are considered, and their performance is evaluated and compared with the measurement based on a single-beam conventional (Poissonian) source and a maximally squeezed (fixed-photon-number) source. The performance advantage that is established depends on parameters such as the intensity of the source, the transmittance of the object, the quantum efficiency of the detectors, the background noise, and the degree of correlation of the photon numbers in the two beams.

Journal of the Optical Society of America A•Feb 1, 1999•28 citations

Photon Noise

Ulrich Hohenester

Graduate texts in physics•Dec 18, 2019•0 citations

Reduction of Quantum Noise in Transmittance Estimation Using PhotoneCorrelated Beams

Majeed M. Hayat, Adel Joobeur, Bahaa E. A. Saleh

The accuracy of optical measurements at low light levels is limited by the quantum noise of the source and by the random nature of the interaction with the measured object. The source noise may be reduced by use of nonclassical photon-number squeezed light. This paper considers the use of two photon-correlated beams (generated, for example, by spontaneous parametric downconversion) to measure the optical transmittance of an object. The photons of each beam obey a random Poisson process, but are synchronized in time. One beam is used to probe the object while the other is used as a reference providing information on the realization of the random arrival of photons at the object. The additional information available by such measurement may be exploited to improve the accuracy of the measurement. Various estimators, including the maximum likelihood estimator, are considered and their performance is evaluated and compared with the measurement based on single-beam conventional (Poisson) source and maximally squeezed (fixed photon number) source. The performance advantage established in this paper depends on parameters such as the intensity of the source, the transmittance of the object, the quantum efficiency of the detectors, the background noise, and the degree of correlation of the photon numbers in the two beams.

Journal of the Optical Society of America A•Jan 1, 1999•0 citations

Demonstration of a bright and compact source of tripartite nonclassical light

Alessia Allevi, Maria Bondani, Matteo G. A. Paris +1 more

We experimentally demonstrate the nonclassical photon number correlations expected in tripartite continuous-variable states obtained by parametric processes. Our scheme involves a single nonlinear crystal, where two interlinked parametric interactions take place simultaneously, and represents a bright and compact source of a sub-shot-noise tripartite light field. We analyze the effects of the pump intensities on the numbers of detected photons and on the amount of noise reduction in some detail, thus demonstrating a good agreement between the experimental data and a single-mode theoretical description.

arXiv:0810.4063•Physical Review A•Dec 1, 2008•23 citations

Measurements of laser excess photon noise

H. Hodara

IEEE Journal of Quantum Electronics•Apr 1, 1966•1 citation
The accuracy of optical measurements at low light levels is limited by the quantum noise of the source and by the random nature of the interaction with the measured object. The source noise may be reduced by use of nonclassical photon-number squeezed light. We consider the use of two photon-correlated beams (generated, for example, by spontaneous parametric downconversion) to measure the optical transmittance of an object. The photons of each beam obey a random Poisson process but are synchronized in time. One beam is used to probe the object, and the other is used as a reference providing information on the realization of the random arrival of photons at the object. The additional information available by such measurement may be exploited to improve the accuracy of the measurement. Various estimators, including the maximum-likelihood estimator, are considered, and their performance is evaluated and compared with the measurement based on a single-beam conventional (Poissonian) source and a maximally squeezed (fixed-photon-number) source. The performance advantage that is established depends on parameters such as the intensity of the source, the transmittance of the object, the quantum efficiency of the detectors, the background noise, and the degree of correlation of the photon numbers in the two beams.
The accuracy of optical measurements at low light levels is limited by the quantum noise of the source and by the random nature of the interaction with the measured object. The source noise may be reduced by use of nonclassical photon-number squeezed light. This paper considers the use of two photon-correlated beams (generated, for example, by spontaneous parametric downconversion) to measure the optical transmittance of an object. The photons of each beam obey a random Poisson process, but are synchronized in time. One beam is used to probe the object while the other is used as a reference providing information on the realization of the random arrival of photons at the object. The additional information available by such measurement may be exploited to improve the accuracy of the measurement. Various estimators, including the maximum likelihood estimator, are considered and their performance is evaluated and compared with the measurement based on single-beam conventional (Poisson) source and maximally squeezed (fixed photon number) source. The performance advantage established in this paper depends on parameters such as the intensity of the source, the transmittance of the object, the quantum efficiency of the detectors, the background noise, and the degree of correlation of the photon numbers in the two beams.
We experimentally demonstrate the nonclassical photon number correlations expected in tripartite continuous-variable states obtained by parametric processes. Our scheme involves a single nonlinear crystal, where two interlinked parametric interactions take place simultaneously, and represents a bright and compact source of a sub-shot-noise tripartite light field. We analyze the effects of the pump intensities on the numbers of detected photons and on the amount of noise reduction in some detail, thus demonstrating a good agreement between the experimental data and a single-mode theoretical description.