Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of the Optical Society of America A

Reduction of Quantum Noise in Transmittance Estimation Using PhotoneCorrelated Beams

Majeed M. Hayat, Adel Joobeur, Bahaa E. A. Saleh

Published Jan 1, 1999• 0 citations
OpenAlex

Abstract

The accuracy of optical measurements at low light levels is limited by the quantum noise of the source and by the random nature of the interaction with the measured object. The source noise may be reduced by use of nonclassical photon-number squeezed light. This paper considers the use of two photon-correlated beams (generated, for example, by spontaneous parametric downconversion) to measure the optical transmittance of an object. The photons of each beam obey a random Poisson process, but are synchronized in time. One beam is used to probe the object while the other is used as a reference providing information on the realization of the random arrival of photons at the object. The additional information available by such measurement may be exploited to improve the accuracy of the measurement. Various estimators, including the maximum likelihood estimator, are considered and their performance is evaluated and compared with the measurement based on single-beam conventional (Poisson) source and maximally squeezed (fixed photon number) source. The performance advantage established in this paper depends on parameters such as the intensity of the source, the transmittance of the object, the quantum efficiency of the detectors, the background noise, and the degree of correlation of the photon numbers in the two beams.

Related papers

Reduction of quantum noise in transmittance estimation using photon-correlated beams

Majeed M. Hayat, Adel Joobeur, Bahaa E. A. Saleh

The accuracy of optical measurements at low light levels is limited by the quantum noise of the source and by the random nature of the interaction with the measured object. The source noise may be reduced by use of nonclassical photon-number squeezed light. We consider the use of two photon-correlated beams (generated, for example, by spontaneous parametric downconversion) to measure the optical transmittance of an object. The photons of each beam obey a random Poisson process but are synchronized in time. One beam is used to probe the object, and the other is used as a reference providing information on the realization of the random arrival of photons at the object. The additional information available by such measurement may be exploited to improve the accuracy of the measurement. Various estimators, including the maximum-likelihood estimator, are considered, and their performance is evaluated and compared with the measurement based on a single-beam conventional (Poissonian) source and a maximally squeezed (fixed-photon-number) source. The performance advantage that is established depends on parameters such as the intensity of the source, the transmittance of the object, the quantum efficiency of the detectors, the background noise, and the degree of correlation of the photon numbers in the two beams.

Journal of the Optical Society of America A•Feb 1, 1999•28 citations

Statistical Noise in Measuring Correlated Photon Beams

Stefania Castelletto, Ivo Pietro Degiovanni, Maria Luisa Rastello

Photon correlated beams, generated by parametric down-conversion in nonlinear crystals (PDC), have been proved successfully for the measurement of quantum efficiency, of single photon detectors [1, 2, 3, 4] and can be used for measuring transmittance, as well. The main feature relies on the realization of two correlated quantum channels yielding coincident events. To reduce uncertainty [4, 5, 6] and determine its ultimate limit, contributions to statistical noise in a real experimental set-up are here investigated, and a general model is proposed to calculate the maximum likelihood best estimators and evaluate the probability of coincidence. In typical measurement scheme a channel is set as trigger (idler, i) and attention is paid to catch at least the same amount of correlated photons in the other channel (signal, s) [4]. Unwanted uncorrelated photons due to PDC itself result in a decreased degree of correlation, noise fluctuations in coincidence measurements and asymmetry between the two channels, whose mean photon rate can be quite different. We indicate by with the mean rate of correlated photons in s and i channels We address the total mean photon rates in both channels as where terms take into account also additive background photon rates due to straylight and detector noise. Actually statistical noise is also due to losses of correlated photons by optical elements, non ideal detectors and electronic devices in both channels. We distinguish, therefore, between optical losses ( transmittance of the correlated photon path), detection losses detectorquantum efficiency), electronic losses associated to the dead times time during which the detection system is unable to detect photons). It is usual to identify dead times as non-extending and extending: in the first case, all photons following a revealed photon within the fixed time interval are ignored, while in the second case any incoming photon produces or prolongs Eventually the finite duration of the time coincidence window, modifies the distribution probability of coincident events. Let us consider the distribution probability of single channel

Kluwer Academic Publishers eBooks•Feb 24, 2006•0 citations

Reduction of quantum noise in image estimation by use of twin-photon beams

Majeed M. Hayat, Bahaa E. A. Saleh, John A. Gubner

An estimate of the transmittance of an object is examined in a twin-photon beam setup. The estimate is based on observing both the photons of one beam and the photons of the twin beam after passage through the object. The performance of the estimate (bias, variance, and mean-square error) is compared to the conventional single-beam measurement. The improvement depends on the photon flux, the counting time, the quantum efficiencies of the detectors, and the value of the measured transmittance itself. In general, a performance advantage is achieved for sufficiently high photon flux or long counting time.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Oct 25, 1996•0 citations

Noise-tolerant object detection and ranging using quantum correlations

Hashir Kuniyil, Helin Ozel, Hasan Yılmaz +1 more

Abstract Imaging, detection and ranging of objects in the presence of significant background noise is a fundamental challenge in optical sensing. Overcoming the limitations imposed in conventional methods, quantum light sources show higher resistance against noise in a time-correlation-based quantum illumination. Here, we introduce the advantage of using not only time correlations but also polarization correlations in photon pairs in the detection of an object that is embedded in a noisy background. In this direction, a time- and polarization-correlated photon pair source using the spontaneous parametric down-conversion process is exploited. We found that the joint measurement of correlated pairs allows distinguishing the signal from the noise photons and that leads to an improved signal-to-noise ratio. Our comparative study revealed that using polarization correlations in addition to time correlations provides improved noise rejection. Furthermore, we show that polarization correlation allows undoing the detector limitation where high background often leads to detector saturation.

arXiv:2111.04062•Journal of Optics•Aug 15, 2022•9 citations

Noise-Tolerant Object Ranging with a Time- and Polarization-Correlated Photon Pair Source

Hashir Kuniyil, Helin Ozel, Hasan Yılmaz +1 more

Imaging, detection and ranging of objects in the presence of significant background noise is a fundamental challenge in optical sensing. Overcoming the limitations imposed in conventional methods, quantum light sources show higher resistance against noise in a time correlation-based detection scheme. Here, we introduce the advantage of using not only time correlations, but also polarization correlations in photon pairs in the detection of an object that is embedded in a noisy background. In this direction, a time- and polarization-correlated photon-pair source using the spontaneous parametric down-conversion process is exploited. We found that the joint measurement of correlated pairs allows to distinguish the signal from the noise photons and that leads to an improved signal-to-noise ratio. Our comparative study revealed that using polarization correlations in addition to time correlations provides improved noise rejection.

•Nov 7, 2021•0 citations

Noise in Classical and Quantum Photon-Correlation Imaging

Bahaa E. A. Saleh, Malvin Carl Teich

Imaging is the estimation of the spatial distribution of a physical object by measuring the optical radiation it emits, or by making use of an optical wave that interacts with the object, via reflection or transmission, for example, before being measured by a detector. The resolution of an imaging system is limited by the inability to localize the optical field at points of the object. Under otherwise ideal conditions, resolution is limited by diffraction. The sensitivity of an imaging system is limited by the uncertainty in the measurement. Under ideal conditions, this is determined by photon noise, which depends on the statistical fluctuations of the light. In conventional imaging systems, an extended detector, such as a CCD camera or an array detector, measures the spatial distribution of the optical intensity, which is proportional to the photon flux density. In interferometric systems, the spatial distribution of the optical field is inferred from measurements of the optical intensity. With the emergence of coherence theory, imaging systems based on measurements of the second-order coherence function at pairs of points in the detection plane were developed. An example is the imaging of an incoherent object based on the van Cittert-Zernike theorem. Imaging systems based on measurement of intensity correlation, or the photon coincidence rate, at pairs of points, were developed in the 1960s. A classic example of the photon-correlation imaging of an object emitting thermal light is stellar imaging using a Hanbury-Brown-Twiss intensity-correlation interferometer. More recently, two-photon light, which may be generated via spontaneous parametric downconversion in a second-order nonlinear optical crystal, has been used for imaging. This type of two-photon (or biphoton) imaging, which has come to be called quantum imaging, is also based on the measurement of photon coincidence by the use of photon-counting array detectors or by scanning two photon-counting detectors at pairs of points. To compare the resolution and sensitivity of imaging systems based on the aforementioned types of measurements, it is necessary to derive expressions for the measured quantities in terms of the object distribution. The point-spread functions based on such expressions can be used to assess the resolution. One measure of the sensitivity of the imaging process is the signal-to-noise ratio (SNR) of the measured variables. The statistical nature of the light source must be known in order to determine the SNR. The purpose of this chapter is to compare the resolution and sensitivity of photon-correlation imaging systems that make use of thermal light and two-photon light. We will henceforth refer to these two imaging modalities as classical and quantum photon-correlation imaging, or simply classical and quantum imaging, respectively. Clearly, light in other quantum states can also be used for imaging.

SPIE eBooks•Mar 16, 2010•3 citations
The accuracy of optical measurements at low light levels is limited by the quantum noise of the source and by the random nature of the interaction with the measured object. The source noise may be reduced by use of nonclassical photon-number squeezed light. This paper considers the use of two photon-correlated beams (generated, for example, by spontaneous parametric downconversion) to measure the optical transmittance of an object. The photons of each beam obey a random Poisson process, but are synchronized in time. One beam is used to probe the object while the other is used as a reference providing information on the realization of the random arrival of photons at the object. The additional information available by such measurement may be exploited to improve the accuracy of the measurement. Various estimators, including the maximum likelihood estimator, are considered and their performance is evaluated and compared with the measurement based on single-beam conventional (Poisson) source and maximally squeezed (fixed photon number) source. The performance advantage established in this paper depends on parameters such as the intensity of the source, the transmittance of the object, the quantum efficiency of the detectors, the background noise, and the degree of correlation of the photon numbers in the two beams.
The accuracy of optical measurements at low light levels is limited by the quantum noise of the source and by the random nature of the interaction with the measured object. The source noise may be reduced by use of nonclassical photon-number squeezed light. We consider the use of two photon-correlated beams (generated, for example, by spontaneous parametric downconversion) to measure the optical transmittance of an object. The photons of each beam obey a random Poisson process but are synchronized in time. One beam is used to probe the object, and the other is used as a reference providing information on the realization of the random arrival of photons at the object. The additional information available by such measurement may be exploited to improve the accuracy of the measurement. Various estimators, including the maximum-likelihood estimator, are considered, and their performance is evaluated and compared with the measurement based on a single-beam conventional (Poissonian) source and a maximally squeezed (fixed-photon-number) source. The performance advantage that is established depends on parameters such as the intensity of the source, the transmittance of the object, the quantum efficiency of the detectors, the background noise, and the degree of correlation of the photon numbers in the two beams.
Photon correlated beams, generated by parametric down-conversion in nonlinear crystals (PDC), have been proved successfully for the measurement of quantum efficiency, of single photon detectors [1, 2, 3, 4] and can be used for measuring transmittance, as well. The main feature relies on the realization of two correlated quantum channels yielding coincident events. To reduce uncertainty [4, 5, 6] and determine its ultimate limit, contributions to statistical noise in a real experimental set-up are here investigated, and a general model is proposed to calculate the maximum likelihood best estimators and evaluate the probability of coincidence. In typical measurement scheme a channel is set as trigger (idler, i) and attention is paid to catch at least the same amount of correlated photons in the other channel (signal, s) [4]. Unwanted uncorrelated photons due to PDC itself result in a decreased degree of correlation, noise fluctuations in coincidence measurements and asymmetry between the two channels, whose mean photon rate can be quite different. We indicate by with the mean rate of correlated photons in s and i channels We address the total mean photon rates in both channels as where terms take into account also additive background photon rates due to straylight and detector noise. Actually statistical noise is also due to losses of correlated photons by optical elements, non ideal detectors and electronic devices in both channels. We distinguish, therefore, between optical losses ( transmittance of the correlated photon path), detection losses detectorquantum efficiency), electronic losses associated to the dead times time during which the detection system is unable to detect photons). It is usual to identify dead times as non-extending and extending: in the first case, all photons following a revealed photon within the fixed time interval are ignored, while in the second case any incoming photon produces or prolongs Eventually the finite duration of the time coincidence window, modifies the distribution probability of coincident events. Let us consider the distribution probability of single channel
An estimate of the transmittance of an object is examined in a twin-photon beam setup. The estimate is based on observing both the photons of one beam and the photons of the twin beam after passage through the object. The performance of the estimate (bias, variance, and mean-square error) is compared to the conventional single-beam measurement. The improvement depends on the photon flux, the counting time, the quantum efficiencies of the detectors, and the value of the measured transmittance itself. In general, a performance advantage is achieved for sufficiently high photon flux or long counting time.
Abstract Imaging, detection and ranging of objects in the presence of significant background noise is a fundamental challenge in optical sensing. Overcoming the limitations imposed in conventional methods, quantum light sources show higher resistance against noise in a time-correlation-based quantum illumination. Here, we introduce the advantage of using not only time correlations but also polarization correlations in photon pairs in the detection of an object that is embedded in a noisy background. In this direction, a time- and polarization-correlated photon pair source using the spontaneous parametric down-conversion process is exploited. We found that the joint measurement of correlated pairs allows distinguishing the signal from the noise photons and that leads to an improved signal-to-noise ratio. Our comparative study revealed that using polarization correlations in addition to time correlations provides improved noise rejection. Furthermore, we show that polarization correlation allows undoing the detector limitation where high background often leads to detector saturation.
Imaging, detection and ranging of objects in the presence of significant background noise is a fundamental challenge in optical sensing. Overcoming the limitations imposed in conventional methods, quantum light sources show higher resistance against noise in a time correlation-based detection scheme. Here, we introduce the advantage of using not only time correlations, but also polarization correlations in photon pairs in the detection of an object that is embedded in a noisy background. In this direction, a time- and polarization-correlated photon-pair source using the spontaneous parametric down-conversion process is exploited. We found that the joint measurement of correlated pairs allows to distinguish the signal from the noise photons and that leads to an improved signal-to-noise ratio. Our comparative study revealed that using polarization correlations in addition to time correlations provides improved noise rejection.
Imaging is the estimation of the spatial distribution of a physical object by measuring the optical radiation it emits, or by making use of an optical wave that interacts with the object, via reflection or transmission, for example, before being measured by a detector. The resolution of an imaging system is limited by the inability to localize the optical field at points of the object. Under otherwise ideal conditions, resolution is limited by diffraction. The sensitivity of an imaging system is limited by the uncertainty in the measurement. Under ideal conditions, this is determined by photon noise, which depends on the statistical fluctuations of the light. In conventional imaging systems, an extended detector, such as a CCD camera or an array detector, measures the spatial distribution of the optical intensity, which is proportional to the photon flux density. In interferometric systems, the spatial distribution of the optical field is inferred from measurements of the optical intensity. With the emergence of coherence theory, imaging systems based on measurements of the second-order coherence function at pairs of points in the detection plane were developed. An example is the imaging of an incoherent object based on the van Cittert-Zernike theorem. Imaging systems based on measurement of intensity correlation, or the photon coincidence rate, at pairs of points, were developed in the 1960s. A classic example of the photon-correlation imaging of an object emitting thermal light is stellar imaging using a Hanbury-Brown-Twiss intensity-correlation interferometer. More recently, two-photon light, which may be generated via spontaneous parametric downconversion in a second-order nonlinear optical crystal, has been used for imaging. This type of two-photon (or biphoton) imaging, which has come to be called quantum imaging, is also based on the measurement of photon coincidence by the use of photon-counting array detectors or by scanning two photon-counting detectors at pairs of points. To compare the resolution and sensitivity of imaging systems based on the aforementioned types of measurements, it is necessary to derive expressions for the measured quantities in terms of the object distribution. The point-spread functions based on such expressions can be used to assess the resolution. One measure of the sensitivity of the imaging process is the signal-to-noise ratio (SNR) of the measured variables. The statistical nature of the light source must be known in order to determine the SNR. The purpose of this chapter is to compare the resolution and sensitivity of photon-correlation imaging systems that make use of thermal light and two-photon light. We will henceforth refer to these two imaging modalities as classical and quantum photon-correlation imaging, or simply classical and quantum imaging, respectively. Clearly, light in other quantum states can also be used for imaging.