Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

A Cryogenic Linear Paul Trap for Quantum Simulation

Paul Hess, Harvey Kaplan, Aaron Lee, Brian Neyenhuis, Lexi Parsagian, Phil Richerme, J.H. Smith, Christopher R. Monroe

Published Jun 11, 2015• 0 citations
OpenAlex

Abstract

statistics. We present progress towards the construction of a cryogenic ion trap apparatus, designed to cryopump background gas within the 4K chamber. The resulting reduction in pressure will allow robust trapping of up to 100 ions in a single chain. Cooling is provided by a closed cycle cryostat with a gas mediated thermal linkage which mechanically decouples the ion trap from the vibrating cold head. A spherical octagon surrounding the ion trap allows optical access for global and individual addressing beams and high numerical aperture uorescence collection.

Related papers

Design and characterization of a cryogenic linear Paul ion trap for ion–neutral reaction studies

Chloé Miossec, Michal Hejduk, Rahul Pandey +2 more

Ultra-high vacuum conditions are ideal for the study of trapped ions. They offer an almost perturbation-free environment, where ions confined in traps can be studied for extended periods of time-facilitating precision measurements and allowing infrequent events to be observed. However, if one wishes to study processes involving molecular ions, it is important to consider the effect of blackbody radiation (BBR). The vast majority of molecular ions interact with BBR. At 300 K, state selection in trapped molecular ions can be rapidly lost (in a matter of seconds). To address this issue, and to maintain state selectivity in trapped molecular ions, a cryogenic ion trap chamber has been constructed and characterized. At the center of the apparatus is a linear Paul ion trap, where Coulomb crystals can be formed for ion-neutral reaction studies. Optical access is provided, for lasers and for imaging of the crystals, alongside ion optics and a flight tube for recording time-of-flight mass spectra. The ion trap region, encased within two nested temperature stages, reaches temperatures below 9 K. To avoid vibrations from the cryocooler impeding laser cooling or imaging of the ions, vibration-damping elements are explicitly included. These components successfully inhibit the coupling of vibrations from the cold head to the ion trap-confirmed by accelerometer measurements and by the resolution of images recorded at the trap center (at 9 and 295 K). These results confirm that the cryogenic ion trap apparatus meets all requirements for studying ion-neutral reactions under cold, controlled conditions.

Review of Scientific Instruments•Mar 1, 2022•13 citations

Cryogenic trapped-ion system for large scale quantum simulation

Guido Pagano, Paul Hess, Harvey Kaplan +9 more

Trapped-ion systems are among the most promising hardware candidates for large scale quantum computing and quantum simulation. In order to scale up such devices, it is necessary to engineer extreme-high vacuum (XHV) environments to prevent background gas from disrupting the ion crystal. Here we present a new cryogenic ion trapping system designed for long time storage of large ion chains. Our apparatus is based on a segmented-blade ion trap enclosed in a 4 K cryostat, which enables us to routinely trap and hold over 100 171 Yb + ions for hours in a linear configuration, due to low background gas pressure from differential cryo-pumping. We characterize the XHV cryogenic environment measuring pressures below by recording both inelastic and elastic collisions between the ion chain and the molecular background gas. We also demonstrate coherent one and two-qubit operations and nearly equidistant ion spacing for chains of up to 44 ions using anharmonic axial potentials, in order to enable better detection and single ion addressing in large ion arrays. We anticipate that this reliable production and lifetime enhancement of large linear ion chains will enable quantum simulation of models that are intractable with classical computer modeling.

arXiv:1802.03118•Quantum Science and Technology•Sep 13, 2018•157 citations

Cryogenic setup for trapped ion quantum computing.

Brandl, MF, van Mourik, MW, Postler, L +15 more

We report on the design of a cryogenic setup for trapped ion quantum computing containing a segmented surface electrode trap. The heat shield of our cryostat is designed to attenuate alternating magnetic field noise, resulting in 120 dB reduction of 50 Hz noise along the magnetic field axis. We combine this efficient magnetic shielding with high optical access required for single ion addressing as well as for efficient state detection by placing two lenses each with numerical aperture 0.23 inside the inner heat shield. The cryostat design incorporates vibration isolation to avoid decoherence of optical qubits due to the motion of the cryostat. We measure vibrations of the cryostat of less than ±20 nm over 2 s. In addition to the cryogenic apparatus, we describe the setup required for an operation with 40Ca+ and 88Sr+ ions. The instability of the laser manipulating the optical qubits in 40Ca+ is characterized by yielding a minimum of its Allan deviation of 2.4 ⋅ 10-15 at 0.33 s. To evaluate the performance of the apparatus, we trapped 40Ca+ ions, obtaining a heating rate of 2.14(16) phonons/s and a Gaussian decay of the Ramsey contrast with a 1/e-time of 18.2(8) ms.

•Nov 1, 2016•26 citations

Cryogenic setup for trapped ion quantum computing

M. F. Brandl, M. W. van Mourik, L. Postler +15 more

We report on the design of a cryogenic setup for trapped ion quantum computing containing a segmented surface electrode trap. The heat shield of our cryostat is designed to attenuate alternating magnetic field noise, resulting in 120 dB reduction of 50 Hz noise along the magnetic field axis. We combine this efficient magnetic shielding with high optical access required for single ion addressing as well as for efficient state detection by placing two lenses each with numerical aperture 0.23 inside the inner heat shield. The cryostat design incorporates vibration isolation to avoid decoherence of optical qubits due to the motion of the cryostat. We measure vibrations of the cryostat of less than ±20 nm over 2 s. In addition to the cryogenic apparatus, we describe the setup required for an operation with 40Ca+ and 88Sr+ ions. The instability of the laser manipulating the optical qubits in 40Ca+ is characterized by yielding a minimum of its Allan deviation of 2.4 ⋅ 10−15 at 0.33 s. To evaluate the performance of the apparatus, we trapped 40Ca+ ions, obtaining a heating rate of 2.14(16) phonons/s and a Gaussian decay of the Ramsey contrast with a 1/e-time of 18.2(8) ms.

arXiv:1607.04980•Review of Scientific Instruments•Nov 1, 2016•77 citations

Cryogenic linear Paul trap for cold highly charged ion experiments

M. Schwarz, Oscar O. Versolato, A. Windberger +9 more

Storage and cooling of highly charged ions require ultra-high vacuum levels obtainable by means of cryogenic methods. We have developed a linear Paul trap operating at 4 K capable of very long ion storage times of about 30 h. A conservative upper bound of the H(2) partial pressure of about 10(-15) mbar (at 4 K) is obtained from this. External ion injection is possible and optimized optical access for lasers is provided, while exposure to black body radiation is minimized. First results of its operation with atomic and molecular ions are presented. An all-solid state laser system at 313 nm has been set up to provide cold Be(+) ions for sympathetic cooling of highly charged ions.

Review of Scientific Instruments•Aug 1, 2012•76 citations

Ultra-low-vibration closed-cycle cryogenic surface-electrode ion trap apparatus

T. Dubielzig, S. Halama, H. Hahn +4 more

We describe the design, commissioning, and operation of an ultra-low-vibration closed-cycle cryogenic ion trap apparatus. One hundred lines for low-frequency signals and eight microwave/radio frequency coaxial feed-lines offer the possibility of implementing a small-scale ion-trap quantum processor or simulator. With all supply cables attached, more than 1.3 W of cooling power at 5 K is still available for absorbing energy from electrical pulses introduced to control ions. The trap itself is isolated from vibrations induced by the cold head using a helium exchange gas interface. The performance of the vibration isolation system has been characterized using a Michelson interferometer, finding residual vibration amplitudes on the order of 10 nm rms. Trapping of 9Be+ ions has been demonstrated using a combination of laser ablation and photoionization.

arXiv:2008.05601•Review of Scientific Instruments•Apr 1, 2021•35 citations
statistics. We present progress towards the construction of a cryogenic ion trap apparatus, designed to cryopump background gas within the 4K chamber. The resulting reduction in pressure will allow robust trapping of up to 100 ions in a single chain. Cooling is provided by a closed cycle cryostat with a gas mediated thermal linkage which mechanically decouples the ion trap from the vibrating cold head. A spherical octagon surrounding the ion trap allows optical access for global and individual addressing beams and high numerical aperture uorescence collection.
Ultra-high vacuum conditions are ideal for the study of trapped ions. They offer an almost perturbation-free environment, where ions confined in traps can be studied for extended periods of time-facilitating precision measurements and allowing infrequent events to be observed. However, if one wishes to study processes involving molecular ions, it is important to consider the effect of blackbody radiation (BBR). The vast majority of molecular ions interact with BBR. At 300 K, state selection in trapped molecular ions can be rapidly lost (in a matter of seconds). To address this issue, and to maintain state selectivity in trapped molecular ions, a cryogenic ion trap chamber has been constructed and characterized. At the center of the apparatus is a linear Paul ion trap, where Coulomb crystals can be formed for ion-neutral reaction studies. Optical access is provided, for lasers and for imaging of the crystals, alongside ion optics and a flight tube for recording time-of-flight mass spectra. The ion trap region, encased within two nested temperature stages, reaches temperatures below 9 K. To avoid vibrations from the cryocooler impeding laser cooling or imaging of the ions, vibration-damping elements are explicitly included. These components successfully inhibit the coupling of vibrations from the cold head to the ion trap-confirmed by accelerometer measurements and by the resolution of images recorded at the trap center (at 9 and 295 K). These results confirm that the cryogenic ion trap apparatus meets all requirements for studying ion-neutral reactions under cold, controlled conditions.
Trapped-ion systems are among the most promising hardware candidates for large scale quantum computing and quantum simulation. In order to scale up such devices, it is necessary to engineer extreme-high vacuum (XHV) environments to prevent background gas from disrupting the ion crystal. Here we present a new cryogenic ion trapping system designed for long time storage of large ion chains. Our apparatus is based on a segmented-blade ion trap enclosed in a 4 K cryostat, which enables us to routinely trap and hold over 100 171 Yb + ions for hours in a linear configuration, due to low background gas pressure from differential cryo-pumping. We characterize the XHV cryogenic environment measuring pressures below by recording both inelastic and elastic collisions between the ion chain and the molecular background gas. We also demonstrate coherent one and two-qubit operations and nearly equidistant ion spacing for chains of up to 44 ions using anharmonic axial potentials, in order to enable better detection and single ion addressing in large ion arrays. We anticipate that this reliable production and lifetime enhancement of large linear ion chains will enable quantum simulation of models that are intractable with classical computer modeling.
We report on the design of a cryogenic setup for trapped ion quantum computing containing a segmented surface electrode trap. The heat shield of our cryostat is designed to attenuate alternating magnetic field noise, resulting in 120 dB reduction of 50 Hz noise along the magnetic field axis. We combine this efficient magnetic shielding with high optical access required for single ion addressing as well as for efficient state detection by placing two lenses each with numerical aperture 0.23 inside the inner heat shield. The cryostat design incorporates vibration isolation to avoid decoherence of optical qubits due to the motion of the cryostat. We measure vibrations of the cryostat of less than ±20 nm over 2 s. In addition to the cryogenic apparatus, we describe the setup required for an operation with 40Ca+ and 88Sr+ ions. The instability of the laser manipulating the optical qubits in 40Ca+ is characterized by yielding a minimum of its Allan deviation of 2.4 ⋅ 10-15 at 0.33 s. To evaluate the performance of the apparatus, we trapped 40Ca+ ions, obtaining a heating rate of 2.14(16) phonons/s and a Gaussian decay of the Ramsey contrast with a 1/e-time of 18.2(8) ms.
We report on the design of a cryogenic setup for trapped ion quantum computing containing a segmented surface electrode trap. The heat shield of our cryostat is designed to attenuate alternating magnetic field noise, resulting in 120 dB reduction of 50 Hz noise along the magnetic field axis. We combine this efficient magnetic shielding with high optical access required for single ion addressing as well as for efficient state detection by placing two lenses each with numerical aperture 0.23 inside the inner heat shield. The cryostat design incorporates vibration isolation to avoid decoherence of optical qubits due to the motion of the cryostat. We measure vibrations of the cryostat of less than ±20 nm over 2 s. In addition to the cryogenic apparatus, we describe the setup required for an operation with 40Ca+ and 88Sr+ ions. The instability of the laser manipulating the optical qubits in 40Ca+ is characterized by yielding a minimum of its Allan deviation of 2.4 ⋅ 10−15 at 0.33 s. To evaluate the performance of the apparatus, we trapped 40Ca+ ions, obtaining a heating rate of 2.14(16) phonons/s and a Gaussian decay of the Ramsey contrast with a 1/e-time of 18.2(8) ms.
Storage and cooling of highly charged ions require ultra-high vacuum levels obtainable by means of cryogenic methods. We have developed a linear Paul trap operating at 4 K capable of very long ion storage times of about 30 h. A conservative upper bound of the H(2) partial pressure of about 10(-15) mbar (at 4 K) is obtained from this. External ion injection is possible and optimized optical access for lasers is provided, while exposure to black body radiation is minimized. First results of its operation with atomic and molecular ions are presented. An all-solid state laser system at 313 nm has been set up to provide cold Be(+) ions for sympathetic cooling of highly charged ions.
We describe the design, commissioning, and operation of an ultra-low-vibration closed-cycle cryogenic ion trap apparatus. One hundred lines for low-frequency signals and eight microwave/radio frequency coaxial feed-lines offer the possibility of implementing a small-scale ion-trap quantum processor or simulator. With all supply cables attached, more than 1.3 W of cooling power at 5 K is still available for absorbing energy from electrical pulses introduced to control ions. The trap itself is isolated from vibrations induced by the cold head using a helium exchange gas interface. The performance of the vibration isolation system has been characterized using a Michelson interferometer, finding residual vibration amplitudes on the order of 10 nm rms. Trapping of 9Be+ ions has been demonstrated using a combination of laser ablation and photoionization.