Review of Scientific Instruments

Design and characterization of a cryogenic linear Paul ion trap for ion–neutral reaction studies

Chloé Miossec, Michal Hejduk, Rahul Pandey, Neville J. A. Coughlan, Brianna R. Heazlewood

Published Mar 1, 2022• 13 citations
Publisher

Abstract

Ultra-high vacuum conditions are ideal for the study of trapped ions. They offer an almost perturbation-free environment, where ions confined in traps can be studied for extended periods of time-facilitating precision measurements and allowing infrequent events to be observed. However, if one wishes to study processes involving molecular ions, it is important to consider the effect of blackbody radiation (BBR). The vast majority of molecular ions interact with BBR. At 300 K, state selection in trapped molecular ions can be rapidly lost (in a matter of seconds). To address this issue, and to maintain state selectivity in trapped molecular ions, a cryogenic ion trap chamber has been constructed and characterized. At the center of the apparatus is a linear Paul ion trap, where Coulomb crystals can be formed for ion-neutral reaction studies. Optical access is provided, for lasers and for imaging of the crystals, alongside ion optics and a flight tube for recording time-of-flight mass spectra. The ion trap region, encased within two nested temperature stages, reaches temperatures below 9 K. To avoid vibrations from the cryocooler impeding laser cooling or imaging of the ions, vibration-damping elements are explicitly included. These components successfully inhibit the coupling of vibrations from the cold head to the ion trap-confirmed by accelerometer measurements and by the resolution of images recorded at the trap center (at 9 and 295 K). These results confirm that the cryogenic ion trap apparatus meets all requirements for studying ion-neutral reactions under cold, controlled conditions.

DOI
10.1063/5.0080458

Related papers

A versatile apparatus for cold ion–molecule reaction dynamics: Integration of laser-cooled ions with velocity- and quantum-state- controlled molecular beams under ultra-high vacuum

Yue Xiao, Liping Wen, Yurun Xie +7 more

We describe a versatile experimental apparatus designed for investigating ion-molecule reaction dynamics at low temperatures under ultra-high vacuum conditions (<8 × 10-11 Torr). The system integrates laser-cooled atomic ions confined in a linear Paul trap with a pulsed molecular beam featuring simultaneous quantum-state and velocity selection. Reaction products are identified using fluorescence imaging and a time-of-flight mass spectrometer. The setup accommodates a broad range of ionic and neutral species-including Be+, C+, H2, N2, O2, H2O, and others-enabling high-sensitivity studies of reaction dynamics. As a benchmark, we present measurements of the Be+ + H2 reaction across a range of collision energies, including reactions with H2 vibrationally excited to the v = 1 level. The apparatus offers fine control over both internal and external degrees of freedom, providing a general platform for cold ion-molecule reaction studies.

Review of Scientific Instruments•Aug 1, 2025•3 citations

An ion trap time-of-flight mass spectrometer with high mass resolution for cold trapped ion experiments

Philipp Christoph Schmid, J. M. Greenberg, Mikhail I. Miller +2 more

Trapping molecular ions that have been sympathetically cooled with laser-cooled atomic ions is a useful platform for exploring cold ion chemistry. We designed and characterized a new experimental apparatus for probing chemical reaction dynamics between molecular cations and neutral radicals at temperatures below 1 K. The ions are trapped in a linear quadrupole radio-frequency trap and sympathetically cooled by co-trapped, laser-cooled, atomic ions. The ion trap is coupled to a time-of-flight mass spectrometer to readily identify product ion species and to accurately determine trapped ion numbers. We discuss, and present in detail, the design of this ion trap time-of-flight mass spectrometer and the electronics required for driving the trap and mass spectrometer. Furthermore, we measure the performance of this system, which yields mass resolutions of m/Δm ≥ 1100 over a wide mass range, and discuss its relevance for future measurements in chemical reaction kinetics and dynamics.

arXiv:1707.07036•Review of Scientific Instruments•Dec 1, 2017•48 citations

Digital ion trap mass spectrometry for cold ion-molecule chemistry

Laura L. Pollum

A promising new approach for studying cold ion-molecule chemical reactions is the combination of laser- or sympathetically-cooled trapped ions and slow-moving molecules from a cold molecule source, such as a quadrupole velocity selector or a Stark decelerator. Previous reaction studies using trapped atomic ions and slow molecules from a quadrupole velocity selector were able to reach average collision energies as low as 1 K. However, the guided molecules had an approximately room temperature rotational energy distribution, so the reactions studied were not truly cold. Thus, a new molecular source for producing translationally and rotationally cold molecules utilizing buffer gas cooling and quadrupole velocity selection was constructed by K. Twyman and characterized for use in cold reaction studies. This new source of cold molecules is referred to as the buffer gas guide. A new ion trap has been designed and built for use with the existing buffer gas guide. The new ion trap apparatus is compact and mechanically compatible with this new guide. It uses a linear Paul ion trap with cylindrical electrodes to trap ions. Two optical axes (one axial and one radial) enable efficient cooling of small ion crystals. A field-free time-of-flight tube and ion detection assembly are also incorporated into the apparatus. A new technique for determining the mass and quantity of trapped ions has also been developed, termed digital ion trap mass spectrometry. The new technique uses a digital RF waveform to trap ions before ejecting the ions radially from the trap using an ejection pulse applied to the trap electrodes. The ions are then detected after free flight along a time-of-flight tube. This technique was characterized by ejecting crystals of various sizes and compositions: Ca+ only, Ca+/CaF +, Ca+/CaOH +/CaOD+, and Ca+/NH +3 /NH +4 /H3O+. A linear relationship between the number of ions ejected (determined by comparing experimental and simulated crystal images) and the integral of the time-of-flight peak was observed for Ca+ and Ca+/CaF +. All mass peaks were resolved. Simulations of the trapped ions and their trajectories through the time-of-flight tube were also performed, and excellent agreement between the simulated and experimental mass resolution was observed. Progress towards combining the buffer gas guide with the previously independent ion trap is also presented. It is anticipated that the combined buffer gas guide ion trap apparatus will enable the study of ion-molecule reactions at low temperatures with translationally and rotationally cold molecules. It is anticipated that the new digital ion trap mass spectrometry technique will simplify the study of reactions when multiple product ions whose masses are separated by only 1 AMU are formed. A new ion trap has been designed and built for use with the existing buffer gas guide. The new ion trap apparatus is compact and mechanically compatible with this new guide. It uses a linear Paul ion trap with cylindrical electrodes to trap ions. Two optical axes (one axial and one radial) enable efficient cooling of small ion crystals. A field-free time-of-flight tube and ion detection assembly are also incorporated into the apparatus. A new technique for determining the mass and quantity of trapped ions has also been developed, termed digital ion trap mass spectrometry. The new technique uses a digital RF waveform to trap ions before ejecting the ions radially from the trap using an ejection pulse applied to the trap electrodes. The ions are then detected after free flight along a time-of-flight tube. This technique was characterized by ejecting crystals of various sizes and compositions: Ca+ only, Ca+/CaF+, Ca+/CaOH+/CaOD+, and Ca+/NH+3/NH+4/H3O+. A linear relationship between the number of ions ejected (determined by comparing experimental and simulated crystal images) and the integral of the time-of-flight peak was observed for Ca+ and Ca+/CaF+. All mass peaks were resolved. Simulations of the trapped ions and their trajectories through the time-of-flight tube were also performed, and excellent agreement between the simulated and experimental mass resolution was observed. Progress towards combining the buffer gas guide with the previously independent ion trap is also presented. It is anticipated that the combined buffer gas guide ion trap apparatus will enable the study of ion-molecule reactions at low temperatures with translationally and rotationally cold molecules. It is anticipated that the new digital ion trap mass spectrometry technique will simplify the study of reactions when multiple product ions whose masses are separated by only 1 AMU are formed.

•Jan 1, 2015•0 citations

Coulomb crystals in a cryogenic Paul trap for sympathetic cooling of molecular ions and highly charged ions

A. Windberger, M. Schwarz, Oscar O. Versolato +11 more

Electron beam ion traps used for spectroscopy of highly charged ions (HCI) produce a deep trapping potential leading to high temperatures of the stored ions, and thus limiting the achievable spectral resolution. A novel device at the Max-Planck-Institut für Kernphysik, the Cryogenic linear Paul Trap Experiment (CryPTEx), attached to an electron beam ion trap, provides a new experimental platform to overcome these limitations. The trap assembly operates at a temperature of 4 K and offers optical access for quantum manipulation and imaging of the trapped ions. Since forbidden optical transitions in HCI do not support direct laser cooling, sympathetic cooling with Coulomb crystals of singly charged ions such as Be+ or Mg+ will be applied in order to reach the natural linewidth of optical forbidden transitions in HCI of interest. With the added advantage of long ion trapping times resulting from residual gas pressures of H2 at 4 K below 10−15 mbar, CryPTEx has been commissioned in collaboration with the Ion Trap Group in Århus using rovibrationally cooled MgH+ ions. Strong suppression of the black body radiation at the trap center, ion storage times of about 28 hours, and largely enhanced population of the rovibrational ground state were achieved.

AIP conference proceedings•Jan 1, 2013•4 citations

A Cryogenic Molecular Ion-Neutral Hybrid Trap

Claudio von Planta

A hybrid trap was developed to confine neutral molecules and molecular ions. We demonstrated the long-term trapping of Stark-decelerated OH radicals in the X 2Pi3/2 (v = 0, J = 3/2, MJ = 3/2, f) state in a permanent magnetic trap. The trap environment was cryogenically cooled to a temperature of 17 K in order to efficiently suppress black-body-radiation-induced pumping of the molecules out of trappable quantum states and collisions with residual background gas molecules which usually limit the trap lifetimes. The cold molecules were kept confined on timescales approaching minutes, an improvement of up to two orders of magnitude compared to room-temperature experiments, at translational temperatures on the order of 25 mK. A cryogenic ion trap was built and laser cooled Ca+ ions were confined. This ion trap can be used to confine sympathetically cooled molecular ions such as N+2or H2O+. Furthermore, a mechanism to superimpose both trap centers by moving the permanent magnets from the magnetic trap over the ion trap was developed. Both traps were characterized and their functionality was proven. The challenges of lasercooling in the strong magnetic field gradients were discussed. The present results pave the way for investigations of cold collisions and reactions with very small reaction rates between molecular ions and neutral molecules, for new avenues for the production of ultracold molecules via sympathetic cooling and for the realization of new forms of hybrid matter with co-trapped atoms or ions.

•Jan 1, 2020•0 citations

Cold reactive collisions between neutral molecules and trapped ions

Lorenzo Salvatore Petralia

This thesis describes the development and demonstration of techniques for the study of ion-neutral reactive collisions at low temperatures conducted using two unique experimental apparatuses comprising radio-frequency Paul traps. One apparatus combines a Stark decelerator with a Paul trap; the other apparatus features a buffer gas cell interfaced with a Paul trap through an electrostatic quadrupole guide. A novel ion trap time-of-flight mass spectrometer has been introduced and characterised. This apparatus is designed to detect the ion products of reactive collisions at low temperatures (< 10 K). This detection approach affords excellent detection efficiency and is broadly applicable to all ion-molecule reactions that one could study within a linear Paul ion trap. A proof-of-principle reaction between xenon ions and neutral ammonia isotopologues is examined to test the performance of the new detection set-up. With the goal of achieving full control over the reaction parameters, the amount of alignment retained by rotationally and translationally cold ammonia molecules exiting the electrostatic guide has been examined using (2 + 1) REMPI detection of the molecules with varying linear polarisation. Simulations suggests how modifications to the current setup will enable full orientation of the cooled molecules reaching the detection region to be achieved. Experiments on cold charge exchange reactions between sympathetically-cooled Xe+ and room temperature ammonia (NH3 and ND3) have been conducted within lasercooled Ca+ Coulomb crystals in a linear Paul ion trap. There is ongoing work to ascertain any difference in reactivity between NH3 and ND3 as the neutral reactant species. Preliminary data are discussed at a qualitative level, with the prospect of observing any isotope effect in this charge transfer process. Charge exchange reaction experiments using cold state-selected ammonia are discussed with the goal of establishing reaction rate constants at different collision energies.

•Jan 1, 2018•0 citations
Ultra-high vacuum conditions are ideal for the study of trapped ions. They offer an almost perturbation-free environment, where ions confined in traps can be studied for extended periods of time-facilitating precision measurements and allowing infrequent events to be observed. However, if one wishes to study processes involving molecular ions, it is important to consider the effect of blackbody radiation (BBR). The vast majority of molecular ions interact with BBR. At 300 K, state selection in trapped molecular ions can be rapidly lost (in a matter of seconds). To address this issue, and to maintain state selectivity in trapped molecular ions, a cryogenic ion trap chamber has been constructed and characterized. At the center of the apparatus is a linear Paul ion trap, where Coulomb crystals can be formed for ion-neutral reaction studies. Optical access is provided, for lasers and for imaging of the crystals, alongside ion optics and a flight tube for recording time-of-flight mass spectra. The ion trap region, encased within two nested temperature stages, reaches temperatures below 9 K. To avoid vibrations from the cryocooler impeding laser cooling or imaging of the ions, vibration-damping elements are explicitly included. These components successfully inhibit the coupling of vibrations from the cold head to the ion trap-confirmed by accelerometer measurements and by the resolution of images recorded at the trap center (at 9 and 295 K). These results confirm that the cryogenic ion trap apparatus meets all requirements for studying ion-neutral reactions under cold, controlled conditions.
We describe a versatile experimental apparatus designed for investigating ion-molecule reaction dynamics at low temperatures under ultra-high vacuum conditions (<8 × 10-11 Torr). The system integrates laser-cooled atomic ions confined in a linear Paul trap with a pulsed molecular beam featuring simultaneous quantum-state and velocity selection. Reaction products are identified using fluorescence imaging and a time-of-flight mass spectrometer. The setup accommodates a broad range of ionic and neutral species-including Be+, C+, H2, N2, O2, H2O, and others-enabling high-sensitivity studies of reaction dynamics. As a benchmark, we present measurements of the Be+ + H2 reaction across a range of collision energies, including reactions with H2 vibrationally excited to the v = 1 level. The apparatus offers fine control over both internal and external degrees of freedom, providing a general platform for cold ion-molecule reaction studies.
Trapping molecular ions that have been sympathetically cooled with laser-cooled atomic ions is a useful platform for exploring cold ion chemistry. We designed and characterized a new experimental apparatus for probing chemical reaction dynamics between molecular cations and neutral radicals at temperatures below 1 K. The ions are trapped in a linear quadrupole radio-frequency trap and sympathetically cooled by co-trapped, laser-cooled, atomic ions. The ion trap is coupled to a time-of-flight mass spectrometer to readily identify product ion species and to accurately determine trapped ion numbers. We discuss, and present in detail, the design of this ion trap time-of-flight mass spectrometer and the electronics required for driving the trap and mass spectrometer. Furthermore, we measure the performance of this system, which yields mass resolutions of m/Δm ≥ 1100 over a wide mass range, and discuss its relevance for future measurements in chemical reaction kinetics and dynamics.
A promising new approach for studying cold ion-molecule chemical reactions is the combination of laser- or sympathetically-cooled trapped ions and slow-moving molecules from a cold molecule source, such as a quadrupole velocity selector or a Stark decelerator. Previous reaction studies using trapped atomic ions and slow molecules from a quadrupole velocity selector were able to reach average collision energies as low as 1 K. However, the guided molecules had an approximately room temperature rotational energy distribution, so the reactions studied were not truly cold. Thus, a new molecular source for producing translationally and rotationally cold molecules utilizing buffer gas cooling and quadrupole velocity selection was constructed by K. Twyman and characterized for use in cold reaction studies. This new source of cold molecules is referred to as the buffer gas guide. A new ion trap has been designed and built for use with the existing buffer gas guide. The new ion trap apparatus is compact and mechanically compatible with this new guide. It uses a linear Paul ion trap with cylindrical electrodes to trap ions. Two optical axes (one axial and one radial) enable efficient cooling of small ion crystals. A field-free time-of-flight tube and ion detection assembly are also incorporated into the apparatus. A new technique for determining the mass and quantity of trapped ions has also been developed, termed digital ion trap mass spectrometry. The new technique uses a digital RF waveform to trap ions before ejecting the ions radially from the trap using an ejection pulse applied to the trap electrodes. The ions are then detected after free flight along a time-of-flight tube. This technique was characterized by ejecting crystals of various sizes and compositions: Ca+ only, Ca+/CaF +, Ca+/CaOH +/CaOD+, and Ca+/NH +3 /NH +4 /H3O+. A linear relationship between the number of ions ejected (determined by comparing experimental and simulated crystal images) and the integral of the time-of-flight peak was observed for Ca+ and Ca+/CaF +. All mass peaks were resolved. Simulations of the trapped ions and their trajectories through the time-of-flight tube were also performed, and excellent agreement between the simulated and experimental mass resolution was observed. Progress towards combining the buffer gas guide with the previously independent ion trap is also presented. It is anticipated that the combined buffer gas guide ion trap apparatus will enable the study of ion-molecule reactions at low temperatures with translationally and rotationally cold molecules. It is anticipated that the new digital ion trap mass spectrometry technique will simplify the study of reactions when multiple product ions whose masses are separated by only 1 AMU are formed. A new ion trap has been designed and built for use with the existing buffer gas guide. The new ion trap apparatus is compact and mechanically compatible with this new guide. It uses a linear Paul ion trap with cylindrical electrodes to trap ions. Two optical axes (one axial and one radial) enable efficient cooling of small ion crystals. A field-free time-of-flight tube and ion detection assembly are also incorporated into the apparatus. A new technique for determining the mass and quantity of trapped ions has also been developed, termed digital ion trap mass spectrometry. The new technique uses a digital RF waveform to trap ions before ejecting the ions radially from the trap using an ejection pulse applied to the trap electrodes. The ions are then detected after free flight along a time-of-flight tube. This technique was characterized by ejecting crystals of various sizes and compositions: Ca+ only, Ca+/CaF+, Ca+/CaOH+/CaOD+, and Ca+/NH+3/NH+4/H3O+. A linear relationship between the number of ions ejected (determined by comparing experimental and simulated crystal images) and the integral of the time-of-flight peak was observed for Ca+ and Ca+/CaF+. All mass peaks were resolved. Simulations of the trapped ions and their trajectories through the time-of-flight tube were also performed, and excellent agreement between the simulated and experimental mass resolution was observed. Progress towards combining the buffer gas guide with the previously independent ion trap is also presented. It is anticipated that the combined buffer gas guide ion trap apparatus will enable the study of ion-molecule reactions at low temperatures with translationally and rotationally cold molecules. It is anticipated that the new digital ion trap mass spectrometry technique will simplify the study of reactions when multiple product ions whose masses are separated by only 1 AMU are formed.
Electron beam ion traps used for spectroscopy of highly charged ions (HCI) produce a deep trapping potential leading to high temperatures of the stored ions, and thus limiting the achievable spectral resolution. A novel device at the Max-Planck-Institut für Kernphysik, the Cryogenic linear Paul Trap Experiment (CryPTEx), attached to an electron beam ion trap, provides a new experimental platform to overcome these limitations. The trap assembly operates at a temperature of 4 K and offers optical access for quantum manipulation and imaging of the trapped ions. Since forbidden optical transitions in HCI do not support direct laser cooling, sympathetic cooling with Coulomb crystals of singly charged ions such as Be+ or Mg+ will be applied in order to reach the natural linewidth of optical forbidden transitions in HCI of interest. With the added advantage of long ion trapping times resulting from residual gas pressures of H2 at 4 K below 10−15 mbar, CryPTEx has been commissioned in collaboration with the Ion Trap Group in Århus using rovibrationally cooled MgH+ ions. Strong suppression of the black body radiation at the trap center, ion storage times of about 28 hours, and largely enhanced population of the rovibrational ground state were achieved.
A hybrid trap was developed to confine neutral molecules and molecular ions. We demonstrated the long-term trapping of Stark-decelerated OH radicals in the X 2Pi3/2 (v = 0, J = 3/2, MJ = 3/2, f) state in a permanent magnetic trap. The trap environment was cryogenically cooled to a temperature of 17 K in order to efficiently suppress black-body-radiation-induced pumping of the molecules out of trappable quantum states and collisions with residual background gas molecules which usually limit the trap lifetimes. The cold molecules were kept confined on timescales approaching minutes, an improvement of up to two orders of magnitude compared to room-temperature experiments, at translational temperatures on the order of 25 mK. A cryogenic ion trap was built and laser cooled Ca+ ions were confined. This ion trap can be used to confine sympathetically cooled molecular ions such as N+2or H2O+. Furthermore, a mechanism to superimpose both trap centers by moving the permanent magnets from the magnetic trap over the ion trap was developed. Both traps were characterized and their functionality was proven. The challenges of lasercooling in the strong magnetic field gradients were discussed. The present results pave the way for investigations of cold collisions and reactions with very small reaction rates between molecular ions and neutral molecules, for new avenues for the production of ultracold molecules via sympathetic cooling and for the realization of new forms of hybrid matter with co-trapped atoms or ions.
This thesis describes the development and demonstration of techniques for the study of ion-neutral reactive collisions at low temperatures conducted using two unique experimental apparatuses comprising radio-frequency Paul traps. One apparatus combines a Stark decelerator with a Paul trap; the other apparatus features a buffer gas cell interfaced with a Paul trap through an electrostatic quadrupole guide. A novel ion trap time-of-flight mass spectrometer has been introduced and characterised. This apparatus is designed to detect the ion products of reactive collisions at low temperatures (< 10 K). This detection approach affords excellent detection efficiency and is broadly applicable to all ion-molecule reactions that one could study within a linear Paul ion trap. A proof-of-principle reaction between xenon ions and neutral ammonia isotopologues is examined to test the performance of the new detection set-up. With the goal of achieving full control over the reaction parameters, the amount of alignment retained by rotationally and translationally cold ammonia molecules exiting the electrostatic guide has been examined using (2 + 1) REMPI detection of the molecules with varying linear polarisation. Simulations suggests how modifications to the current setup will enable full orientation of the cooled molecules reaching the detection region to be achieved. Experiments on cold charge exchange reactions between sympathetically-cooled Xe+ and room temperature ammonia (NH3 and ND3) have been conducted within lasercooled Ca+ Coulomb crystals in a linear Paul ion trap. There is ongoing work to ascertain any difference in reactivity between NH3 and ND3 as the neutral reactant species. Preliminary data are discussed at a qualitative level, with the prospect of observing any isotope effect in this charge transfer process. Charge exchange reaction experiments using cold state-selected ammonia are discussed with the goal of establishing reaction rate constants at different collision energies.