A promising new approach for studying cold ion-molecule chemical reactions is the combination of laser- or sympathetically-cooled trapped ions and slow-moving molecules from a cold molecule source, such as a quadrupole velocity selector or a Stark decelerator. Previous reaction studies using trapped atomic ions and slow molecules from a quadrupole velocity selector were able to reach average collision energies as low as 1 K. However, the guided molecules had an approximately room temperature rotational energy distribution, so the reactions studied were not truly cold. Thus, a new molecular source for producing translationally and rotationally cold molecules utilizing buffer gas cooling and quadrupole velocity selection was constructed by K. Twyman and characterized for use in cold reaction studies. This new source of cold molecules is referred to as the buffer gas guide. A new ion trap has been designed and built for use with the existing buffer gas guide. The new ion trap apparatus is compact and mechanically compatible with this new guide. It uses a linear Paul ion trap with cylindrical electrodes to trap ions. Two optical axes (one axial and one radial) enable efficient cooling of small ion crystals. A field-free time-of-flight tube and ion detection assembly are also incorporated into the apparatus. A new technique for determining the mass and quantity of trapped ions has also been developed, termed digital ion trap mass spectrometry. The new technique uses a digital RF waveform to trap ions before ejecting the ions radially from the trap using an ejection pulse applied to the trap electrodes. The ions are then detected after free flight along a time-of-flight tube. This technique was characterized by ejecting crystals of various sizes and compositions: Ca+ only, Ca+/CaF +, Ca+/CaOH +/CaOD+, and Ca+/NH +3 /NH +4 /H3O+. A linear relationship between the number of ions ejected (determined by comparing experimental and simulated crystal images) and the integral of the time-of-flight peak was observed for Ca+ and Ca+/CaF +. All mass peaks were resolved. Simulations of the trapped ions and their trajectories through the time-of-flight tube were also performed, and excellent agreement between the simulated and experimental mass resolution was observed. Progress towards combining the buffer gas guide with the previously independent ion trap is also presented. It is anticipated that the combined buffer gas guide ion trap apparatus will enable the study of ion-molecule reactions at low temperatures with translationally and rotationally cold molecules. It is anticipated that the new digital ion trap mass spectrometry technique will simplify the study of reactions when multiple product ions whose masses are separated by only 1 AMU are formed. A new ion trap has been designed and built for use with the existing buffer gas guide. The new ion trap apparatus is compact and mechanically compatible with this new guide. It uses a linear Paul ion trap with cylindrical electrodes to trap ions. Two optical axes (one axial and one radial) enable efficient cooling of small ion crystals. A field-free time-of-flight tube and ion detection assembly are also incorporated into the apparatus. A new technique for determining the mass and quantity of trapped ions has also been developed, termed digital ion trap mass spectrometry. The new technique uses a digital RF waveform to trap ions before ejecting the ions radially from the trap using an ejection pulse applied to the trap electrodes. The ions are then detected after free flight along a time-of-flight tube. This technique was characterized by ejecting crystals of various sizes and compositions: Ca+ only, Ca+/CaF+, Ca+/CaOH+/CaOD+, and Ca+/NH+3/NH+4/H3O+. A linear relationship between the number of ions ejected (determined by comparing experimental and simulated crystal images) and the integral of the time-of-flight peak was observed for Ca+ and Ca+/CaF+. All mass peaks were resolved. Simulations of the trapped ions and their trajectories through the time-of-flight tube were also performed, and excellent agreement between the simulated and experimental mass resolution was observed. Progress towards combining the buffer gas guide with the previously independent ion trap is also presented. It is anticipated that the combined buffer gas guide ion trap apparatus will enable the study of ion-molecule reactions at low temperatures with translationally and rotationally cold molecules. It is anticipated that the new digital ion trap mass spectrometry technique will simplify the study of reactions when multiple product ions whose masses are separated by only 1 AMU are formed.
A promising new approach for studying cold ion-molecule chemical reactions is the combination of laser- or sympathetically-cooled trapped ions and slow-moving molecules from a cold molecule source, such as a quadrupole velocity selector or a Stark decelerator. Previous reaction studies using trapped atomic ions and slow molecules from a quadrupole velocity selector were able to reach average collision energies as low as 1 K. However, the guided molecules had an approximately room temperature rotational energy distribution, so the reactions studied were not truly cold. Thus, a new molecular source for producing translationally and rotationally cold molecules utilizing buffer gas cooling and quadrupole velocity selection was constructed by K. Twyman and characterized for use in cold reaction studies. This new source of cold molecules is referred to as the buffer gas guide. A new ion trap has been designed and built for use with the existing buffer gas guide. The new ion trap apparatus is compact and mechanically compatible with this new guide. It uses a linear Paul ion trap with cylindrical electrodes to trap ions. Two optical axes (one axial and one radial) enable efficient cooling of small ion crystals. A field-free time-of-flight tube and ion detection assembly are also incorporated into the apparatus. A new technique for determining the mass and quantity of trapped ions has also been developed, termed digital ion trap mass spectrometry. The new technique uses a digital RF waveform to trap ions before ejecting the ions radially from the trap using an ejection pulse applied to the trap electrodes. The ions are then detected after free flight along a time-of-flight tube. This technique was characterized by ejecting crystals of various sizes and compositions: Ca+ only, Ca+/CaF +, Ca+/CaOH +/CaOD+, and Ca+/NH +3 /NH +4 /H3O+. A linear relationship between the number of ions ejected (determined by comparing experimental and simulated crystal images) and the integral of the time-of-flight peak was observed for Ca+ and Ca+/CaF +. All mass peaks were resolved. Simulations of the trapped ions and their trajectories through the time-of-flight tube were also performed, and excellent agreement between the simulated and experimental mass resolution was observed. Progress towards combining the buffer gas guide with the previously independent ion trap is also presented. It is anticipated that the combined buffer gas guide ion trap apparatus will enable the study of ion-molecule reactions at low temperatures with translationally and rotationally cold molecules. It is anticipated that the new digital ion trap mass spectrometry technique will simplify the study of reactions when multiple product ions whose masses are separated by only 1 AMU are formed. A new ion trap has been designed and built for use with the existing buffer gas guide. The new ion trap apparatus is compact and mechanically compatible with this new guide. It uses a linear Paul ion trap with cylindrical electrodes to trap ions. Two optical axes (one axial and one radial) enable efficient cooling of small ion crystals. A field-free time-of-flight tube and ion detection assembly are also incorporated into the apparatus. A new technique for determining the mass and quantity of trapped ions has also been developed, termed digital ion trap mass spectrometry. The new technique uses a digital RF waveform to trap ions before ejecting the ions radially from the trap using an ejection pulse applied to the trap electrodes. The ions are then detected after free flight along a time-of-flight tube. This technique was characterized by ejecting crystals of various sizes and compositions: Ca+ only, Ca+/CaF+, Ca+/CaOH+/CaOD+, and Ca+/NH+3/NH+4/H3O+. A linear relationship between the number of ions ejected (determined by comparing experimental and simulated crystal images) and the integral of the time-of-flight peak was observed for Ca+ and Ca+/CaF+. All mass peaks were resolved. Simulations of the trapped ions and their trajectories through the time-of-flight tube were also performed, and excellent agreement between the simulated and experimental mass resolution was observed. Progress towards combining the buffer gas guide with the previously independent ion trap is also presented. It is anticipated that the combined buffer gas guide ion trap apparatus will enable the study of ion-molecule reactions at low temperatures with translationally and rotationally cold molecules. It is anticipated that the new digital ion trap mass spectrometry technique will simplify the study of reactions when multiple product ions whose masses are separated by only 1 AMU are formed.
This thesis describes the development and demonstration of techniques for the study of ion-neutral reactive collisions at low temperatures conducted using two unique experimental apparatuses comprising radio-frequency Paul traps. One apparatus combines a Stark decelerator with a Paul trap; the other apparatus features a buffer gas cell interfaced with a Paul trap through an electrostatic quadrupole guide. A novel ion trap time-of-flight mass spectrometer has been introduced and characterised. This apparatus is designed to detect the ion products of reactive collisions at low temperatures (< 10 K). This detection approach affords excellent detection efficiency and is broadly applicable to all ion-molecule reactions that one could study within a linear Paul ion trap. A proof-of-principle reaction between xenon ions and neutral ammonia isotopologues is examined to test the performance of the new detection set-up. With the goal of achieving full control over the reaction parameters, the amount of alignment retained by rotationally and translationally cold ammonia molecules exiting the electrostatic guide has been examined using (2 + 1) REMPI detection of the molecules with varying linear polarisation. Simulations suggests how modifications to the current setup will enable full orientation of the cooled molecules reaching the detection region to be achieved. Experiments on cold charge exchange reactions between sympathetically-cooled Xe+ and room temperature ammonia (NH3 and ND3) have been conducted within lasercooled Ca+ Coulomb crystals in a linear Paul ion trap. There is ongoing work to ascertain any difference in reactivity between NH3 and ND3 as the neutral reactant species. Preliminary data are discussed at a qualitative level, with the prospect of observing any isotope effect in this charge transfer process. Charge exchange reaction experiments using cold state-selected ammonia are discussed with the goal of establishing reaction rate constants at different collision energies.
This thesis describes the combination of two sources of cold atomic or molecular species which can be used to study a wide range of ion-molecule reactions. The challenges in forming these species and in determining the fate of reactive events are explored throughout. Reactions occur in a volume within a radio-frequency ion trap, in which ions have previously been cooled to sub-Kelvin temperatures. Ions are laser-cooled, with migration of ions slowed sufficiently to form a quasi-crystalline spheroidal structure, deemed a Coulomb crystal. Fluorescence emitted as a consequence of laser-cooling is detected; the subsequent fluorescence profiles are used to determine the number of ions in the crystal and, in combination with complementary simulations, the temperature of these ions. Motion imparted by trapping fields can be substantial and simulations are required to accurately determine collision energies. A beam of decelerated molecules is aimed at this stationary ion target. An ammonia seeded molecular beam enters a Stark decelerator, based on the original design of Meijer and co-workers. The decelerator uses time-varying electric fields to remove kinetic energy from the molecules, which exit at speeds down to 35 m/s. A fast-opening shutter and focussing elements are subsequently used to maximise the decelerated flux in the reaction volume while minimising undecelerated molecule transmission. Substantial fluxes of decelerated ammonia are obtained with narrow velocity distributions to provide a suitable source of reactant molecules. Combination of these two techniques permits studies of reactions between atomic ions and decelerated molecules that can be entirely state-specific. Changes in the Coulomb crystal fluorescence profile denote changes in the ion identities, the rate of these changes can be used to obtain rate constants. Determination of rate constants is even possible despite the fact that neither reactant nor product ions are directly observed. This work has studied reactions between sympathetically cooled Xe+ ions and guided ND3 and has obtained data consistent with prior studies. Determination of reactive events is complicated if ion identities can change without affecting the fluorescence profile, or if multiple reaction channels are possible. A range of spectroscopic techniques are discussed and considered in regards to determining rate constants and product identities. Pulsed axial excitation of trapped ions can follow rapid changes in average ion weights and subtle changes for small crystals. Time-of-flight mass spectrometry is also demonstrated using the trapping electrodes and is suitable for discrimination of ions formed within the trap.
Trapping molecular ions that have been sympathetically cooled with laser-cooled atomic ions is a useful platform for exploring cold ion chemistry. We designed and characterized a new experimental apparatus for probing chemical reaction dynamics between molecular cations and neutral radicals at temperatures below 1 K. The ions are trapped in a linear quadrupole radio-frequency trap and sympathetically cooled by co-trapped, laser-cooled, atomic ions. The ion trap is coupled to a time-of-flight mass spectrometer to readily identify product ion species and to accurately determine trapped ion numbers. We discuss, and present in detail, the design of this ion trap time-of-flight mass spectrometer and the electronics required for driving the trap and mass spectrometer. Furthermore, we measure the performance of this system, which yields mass resolutions of m/Δm ≥ 1100 over a wide mass range, and discuss its relevance for future measurements in chemical reaction kinetics and dynamics.
The recent development of a range of techniques for producing cold atoms and molecules at very low translational temperatures T < or = 1 K has provided the opportunity to investigate collisional processes in a new physical regime. We have recently presented a new experimental method to study low-temperature reactive collisions between translationally cold ions and neutral molecules (S. Willitsch et al., Phys. Rev. Lett. 2008, 100, 043203). Our technique relies on the combination of a quadrupole-guide velocity selector for the generation of translationally cold neutral molecules with a facility to produce ordered structures of cold ions (Coulomb crystals) by laser cooling in a linear quadrupole ion trap. The strong localisation of the ions in the trap in combination with the high sensitivity of laser-induced-fluorescence detection enabled us to study chemical reactions on the single-particle level, down to temperatures of T approximately 1 K. In the current paper, we present a detailed characterisation of the scope and limitations of this method based on our study of the reaction between laser-cooled Ca+ ions and velocity-selected CH3F molecules. The properties of our cold-neutrals source and the dependence of the measured rate constant on the shape of the Coulomb crystals, trapping and laser-cooling parameters are discussed. An extension of our technique for the study of low-temperature reactions with sympathetically cooled molecular ions (translational temperature T > 10 mK) is presented and first results on the charge-transfer reaction between OCS+ and ND3 are discussed. Finally, perspectives for further developments of our method are explored.
We have developed a combined Stark-velocity-filter--ion-trap apparatus for the purpose of reaction-rate measurements between cold trapped ions and slow polar molecules under ultrahigh vacuum conditions. The prerequisite steps such as the characterization of velocity-selected polar molecules (PM), namely ND3, H2CO, and CH3CN, were performed using time-of-flight (TOF) measurements. We confirmed the generation of slow ND3, H2CO, and CH3CN molecules having thermal energies of a few Kelvin. Additionally, the number densities of the slow velocity-filtered polar molecules were determined to be in the range of n=104 to 106 cm${}^{\ensuremath{-}3}$ by calibrating the TOF signals. In a first experiment, the Stark velocity filter was connected to a cryogenic linear Paul trap and reaction-rate measurements between laser-cooled Ca+ Coulomb crystals and velocity-selected polar molecules were carried out. The observed reaction rates are of the order of 10${}^{\ensuremath{-}5}$ s${}^{\ensuremath{-}1}$, which are much slower than typical reaction rates of molecular ion--polar-molecule reactions at low temperatures. The present results confirm that reaction-rate measurements between velocity-selected polar molecules and sympathetically cooled molecular ions cooled by a laser-cooled Ca+ Coulomb crystal can be performed. Next we measured the reaction rates between sympathetically cooled nonfluorescent stored ion molecules namely N2H+ ions and velocity-selected CH3CN molecules at the average reaction energy of about 3 K. The measured reaction rate of 2.0(2)$\ifmmode\times\else\texttimes\fi{}10{}^{\ensuremath{-}3}$ s${}^{\ensuremath{-}1}$ is much faster than those of the Ca++PM reactions. This is strong evidence that the velocity-selected polar molecules undergo reactive collisions. We also confirmed that the present reaction-rate constant of CH3CN+N2H+ $\ensuremath{\rightarrow}$ CH3CNH++N2 is consistent with the estimated values from the room temperature results and the trajectory-scaling formula of Su et al. In the future, the present velocity-filter combined cryogenic trap apparatus will enable us to perform systematic measurements of cold ion--polar-molecule reactions, which are important problems from a fundamental viewpoint and also contribute to astrochemistry.
This thesis describes the study of a range of ion-molecule reactions at very low collision energies using a newly developed experimental technique which involves the reaction of velocity-selected beams of translationally cold neutral molecules with very low kinetic energy ion ensembles. These studies have been enabled by the construction of a new apparatus for trapping and laser-cooling gas phase atomic ions (40Ca⁺). The laser-cooling process results in the formation of ordered, low kinetic energy, lattice-like ion structures, also known as "Coulomb crystals". The properties of single and multicomponent Coulomb crystals (which may also involve molecular ions), and their manipulation via modulation of the applied fields, are explored experimentally and with the use of molecular dynamics simulations. Variations in the laser-cooling parameters are shown to result in different steady-state populations of the electronic states of 40Ca⁺ involved with the laser cooling cycle, and these are modelled within an appropriate theoretical framework. The imaging of 40Ca⁺ fluorescence as a function of time allows the study of various ion-molecule reactions at collision energies around 300 K, with single ion sensitivity. These reaction studies are extended to low-temperature (collision energies close to 1 K), by combination of the ion trap apparatus with a bent quadrupole guide velocity-selector. Ion-molecule collision energies are shown to be variable over a short range through a change in the quadrupole guide voltage, or the ion trapping parameters; the effect of these modulations on the rate constant is explored for Ca⁺ + CH₃F. Bimolecular rate constants for the reactions of 40Ca⁺ with CH₃F, CH₂F₂ and CH₃Cl have been determined for a range of 40Ca⁺ state populations, allowing resolution of the global rate contributions from the ground and combined excited states. These results are analysed in the context of capture theories and ab initio electronic structure calculations. In each case, suppression of the ground state rate constant is explained by the presence of either a submerged or real barrier on the ground state potential surface. Rates of reaction from the combined excited states are generally found to be in line with capture theories, and in some cases variation is found between the high and low collision energy regimes. Molecular product ions generated in these experiments have been shown to be sympathetically-cooled into the crystal structure, and subsequently identified through resonance-excitation mass spectrometry. Molecular ions were also produced by multiphoton laser ionisation of a thermal background gas of OCS molecules. An ion-molecule reaction involving a molecular ion, that of charge transfer between OCS⁺ and ND₃, has been studied at a collision energy near 1 K for the first time using sympathetically-cooled OCS⁺ and velocity-selected ND₃. These experiments illustrate the generality of the techniques described herein, and should lead to many possibilities for future studies.