Coherent Electrometer Using Hybridised Double Quantum Dot - Resonator States

Samuel Andersson, P. Glidic, Andrea Cicovic, Harald Havir, Sebastian Lehmann, Kimberly A. Dick, V. F. Maisi

Published Nov 6, 2026• 0 citations
arXivHTMLPDF

Abstract

Probing the change in conductance or reactance of a charge sensitive system using an rf cavity is a standard way of doing fast single-charge electrometry. In this article, we present a detector concept which is instead based on coherent interaction. We show that the coherent interaction between a microwave resonator and double quantum dot gives rise to a fast, highly sensitive electrometer. The coherent electrometer achieves a state-of-the-art readout speed, resolving two charge states with SNR of 11.7 in 16 $μ$s, with a readout signal two orders of magnitude lower in power than previously required to reach this speed. In this way, heating of the sample becomes negligible. Thanks to its sensitivity and low dissipation, the coherent electrometer opens up the avenue for quantum limited charge detection with nanosecond speed and minimal back-action.

DOI
10.48550/arxiv.2611.10274

Related papers

Fast Readout in Semiconductor Quantum Dots

Wilson, Tim J

The need for fast readout to measure the state of a quantum dot device has important applications in the capabilities of using them as a means for quantum information processing. Traditional charge sensors used to readout the charge state of a quantum dot device are very robust and sensitive electrometers that have been in use since the late 1980s. They pose an issue to the future of quantum dots as a viable means of quantum computing, and that is in their slow acquisition times of the charge state of the quantum dot. This rate of measurement means that implementing any quantum error correction scheme becomes very difficult or even unfeasible as the coherence times of these semiconductor systems is short compared to charge sensor’s acquisition times. A possibility to speed up the measurement process of the charge state is possible thanks to the atomic molecular and optical (AMO) physics community.Cavity quantum electrodynamics (CQED) is the study of light-matter interactions when both the light and matter are taken to be quantized. A photon may interact with an atom via a dipole interaction to excite it from its ground state to its excited state, and the reverse can occur where the atom emits a photon and decays from its excited state ii to the ground state. This fundamental interaction which has been extensively studied in the AMO community since the early 1960s had been adopted by the superconducting qubit community to measure the state of their qubits. These superconducting qubits, representing atoms, which are coupled to a resonant structure on chip, which represents the photons that can interact with the artificial atom. Since these systems were not traditional trapped or neutral atoms interacting with a photon via a laser, but instead planar circuit structures, the superconducting qubit community re-coined the term cavity quantum electrodynamics to circuit quantum electrodynamics, which we will refer to as cQED.The quantum dot community adapted these methods of what is known as dispersive readout; a capacitive change of the atomic like system, results in a dispersive shift which then alters the characteristic frequency response of the resonant structure. This has allowed for a new kind of charge sensor by means of measuring the resonators response due to its coupling to a quantum dot system. This can be done with very high frequency microwave circuitry, allowing much faster readout than is capable via traditional charge sensors. Thus, allowing a pathway to implement quantum error correction schemes with reasonable times compared to any dephasing or decoherence times of the semiconductor system. Furthermore, such fast readout allows for feedback protocols to be implemented to the system to correct for certain undesirable effects due to instruments or the system itself. Our work focuses on a limit of this cQED interaction of the quantum dots to a resonant structure allowing us to do fast readout of the quantum dot charge states via a dispersive shift.The work I will demonstrate in this dissertation will be in the efforts of fast readout on the charge occupation of a double quantum dot system which is galvanically coupled to a superconducting microwave resonator. This was done in a Si/SiGe heterostructure system where I designed, simulated, and fabricated the device which was optimized to have a stronger dispersive shift signal due to an enhanced gate lever arm that couples to the resonator. I will discuss our results of attaining a minimum integration time of 34.54 ns for a unity signal to noise ratio. This demonstrates a fast readout system in the community iii which could be extended to allow for even better readout speeds with faster instruments than what were available to me for the experiment. I will further discuss our characterization of the hybrid system and how we extracted a charge noise due to charging events between the two dots in our system up to around 10 kHz. This work demonstrates a robust dispersive readout scheme which helps in the scalability of hybrid superconducting-semiconducting architectures for means of quantum information processing.

•Dec 12, 2025•0 citations

Charge and Spin State Readout of a Double Quantum Dot Coupled to a Resonator

Karl D. Petersson, C. G. Smith, D. Anderson +3 more

State readout is a key requirement for a quantum computer. For semiconductor-based qubit devices it is usually accomplished using a separate mesoscopic electrometer. Here we demonstrate a simple detection scheme in which a radio frequency resonant circuit coupled to a semiconductor double quantum dot is used to probe its charge and spin states. These results demonstrate a new noninvasive technique for measuring charge and spin states in quantum dot systems without requiring a separate mesoscopic detector.

arXiv:1004.4047•Nano Letters•Jul 21, 2010•169 citations

Fast single-charge sensing with a rf quantum point contact

D. J. Reilly, Charles M. Marcus, Micah P. Hanson +1 more

We report high-bandwidth charge sensing measurements using a GaAs quantum point contact embedded in a radio frequency impedance matching circuit (rf-QPC). With the rf-QPC biased near pinch-off where it is most sensitive to charge, we demonstrate a conductance sensitivity of 5×10−6e2∕hHz−1∕2 with a bandwidth of 8MHz. Single-shot readout of a proximal few-electron double quantum dot is investigated in a mode where the rf-QPC back action is rapidly switched.

arXiv:0707.2946•Applied Physics Letters•Oct 15, 2007•299 citations

Double quantum dot coupled to a radio-frequency single-electron transistor: Quantum measurement and back action

Madhu Thalakulam

The radio-frequency superconducting single electron transistor (RF-SET) is a highly sensitive and fast electrometer operating near the quantum limit. The back-action current noise of the SET induces voltage fluctuations on the system it is coupled to, dephasing its charge states. Here we propose to study the back action of the RF-SET by means of a double quantum dot (DQD) and, an RF-SET electrostatically coupled to one of the two dots. The inelastic current through the DQD is very sensitive to the spectral density of the voltage fluctuations in the nearby environment. By properly choosing the dot size and inter-dot tunnel barrier thickness, one can cause inelastic process to dominate the transport processes. A measurement of the inelastic current through the double dot system can then be used to calculate the spectral density of noise associated with the RF-SET and hence its back action. The design, fabrication and characterization of an RF-SET/DQD system is discussed in this work. Real-time studies of electron dynamics in coupled dots are also addressed.

•Jan 1, 2004•0 citations

Dispersive Readout of a Few-Electron Double Quantum Dot with Fast rf Gate Sensors

James Colless, Alice Mahoney, J. M. Hornibrook +4 more

We report the dispersive charge-state readout of a double quantum dot in the few-electron regime using the in situ gate electrodes as sensitive detectors. We benchmark this gate sensing technique against the well established quantum point contact charge detector and find comparable performance with a bandwidth of $\ensuremath{\sim}10\text{ }\text{ }\mathrm{MHz}$ and an equivalent charge sensitivity of $\ensuremath{\sim}6.3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}3}\text{ }\text{ }e/\sqrt{\mathrm{Hz}}$. Dispersive gate sensing alleviates the burden of separate charge detectors for quantum dot systems and promises to enable readout of qubits in scaled-up arrays.

arXiv:1210.4645•Physical Review Letters•Jan 25, 2013•215 citations

Probing the limits of gate-based charge sensing

M. Fernando González-Zalba, Sylvain Barraud, Andrew J. Ferguson +1 more

Quantum computation requires a qubit-specific measurement capability to readout the final state of individual qubits. Promising solid-state architectures use external readout electrometers but these can be replaced by a more compact readout element, an in situ gate sensor. Gate-sensing couples the qubit to a resonant circuit via a gate and probes the qubit’s radiofrequency polarizability. Here we investigate the ultimate performance of such a resonant readout scheme and the noise sources that limit its operation. We find a charge sensitivity of 37 μe Hz−1/2, the best value reported for this technique, using the example of a gate sensor strongly coupled to a double quantum dot at the corner states of a silicon nanowire transistor. We discuss the experimental factors limiting gate detection and highlight ways to optimize its sensitivity. In total, resonant gate-based readout has advantages over external electrometers both in terms of reduction of circuit elements as well as absolute charge sensitivity. Reading out the state of quantum bits is an essential requirement that any quantum computer implementation must satisfy. Gonzalez-Zalba et al. now show that in situresonant gate-based detection can be a more sensitive approach than external electrometers while reducing the qubit architecture’s complexity.

arXiv:1405.2755•Nature Communications•Jan 20, 2015•177 citations
Probing the change in conductance or reactance of a charge sensitive system using an rf cavity is a standard way of doing fast single-charge electrometry. In this article, we present a detector concept which is instead based on coherent interaction. We show that the coherent interaction between a microwave resonator and double quantum dot gives rise to a fast, highly sensitive electrometer. The coherent electrometer achieves a state-of-the-art readout speed, resolving two charge states with SNR of 11.7 in 16 μμμs, with a readout signal two orders of magnitude lower in power than previously required to reach this speed. In this way, heating of the sample becomes negligible. Thanks to its sensitivity and low dissipation, the coherent electrometer opens up the avenue for quantum limited charge detection with nanosecond speed and minimal back-action.
The need for fast readout to measure the state of a quantum dot device has important applications in the capabilities of using them as a means for quantum information processing. Traditional charge sensors used to readout the charge state of a quantum dot device are very robust and sensitive electrometers that have been in use since the late 1980s. They pose an issue to the future of quantum dots as a viable means of quantum computing, and that is in their slow acquisition times of the charge state of the quantum dot. This rate of measurement means that implementing any quantum error correction scheme becomes very difficult or even unfeasible as the coherence times of these semiconductor systems is short compared to charge sensor’s acquisition times. A possibility to speed up the measurement process of the charge state is possible thanks to the atomic molecular and optical (AMO) physics community.Cavity quantum electrodynamics (CQED) is the study of light-matter interactions when both the light and matter are taken to be quantized. A photon may interact with an atom via a dipole interaction to excite it from its ground state to its excited state, and the reverse can occur where the atom emits a photon and decays from its excited state ii to the ground state. This fundamental interaction which has been extensively studied in the AMO community since the early 1960s had been adopted by the superconducting qubit community to measure the state of their qubits. These superconducting qubits, representing atoms, which are coupled to a resonant structure on chip, which represents the photons that can interact with the artificial atom. Since these systems were not traditional trapped or neutral atoms interacting with a photon via a laser, but instead planar circuit structures, the superconducting qubit community re-coined the term cavity quantum electrodynamics to circuit quantum electrodynamics, which we will refer to as cQED.The quantum dot community adapted these methods of what is known as dispersive readout; a capacitive change of the atomic like system, results in a dispersive shift which then alters the characteristic frequency response of the resonant structure. This has allowed for a new kind of charge sensor by means of measuring the resonators response due to its coupling to a quantum dot system. This can be done with very high frequency microwave circuitry, allowing much faster readout than is capable via traditional charge sensors. Thus, allowing a pathway to implement quantum error correction schemes with reasonable times compared to any dephasing or decoherence times of the semiconductor system. Furthermore, such fast readout allows for feedback protocols to be implemented to the system to correct for certain undesirable effects due to instruments or the system itself. Our work focuses on a limit of this cQED interaction of the quantum dots to a resonant structure allowing us to do fast readout of the quantum dot charge states via a dispersive shift.The work I will demonstrate in this dissertation will be in the efforts of fast readout on the charge occupation of a double quantum dot system which is galvanically coupled to a superconducting microwave resonator. This was done in a Si/SiGe heterostructure system where I designed, simulated, and fabricated the device which was optimized to have a stronger dispersive shift signal due to an enhanced gate lever arm that couples to the resonator. I will discuss our results of attaining a minimum integration time of 34.54 ns for a unity signal to noise ratio. This demonstrates a fast readout system in the community iii which could be extended to allow for even better readout speeds with faster instruments than what were available to me for the experiment. I will further discuss our characterization of the hybrid system and how we extracted a charge noise due to charging events between the two dots in our system up to around 10 kHz. This work demonstrates a robust dispersive readout scheme which helps in the scalability of hybrid superconducting-semiconducting architectures for means of quantum information processing.
State readout is a key requirement for a quantum computer. For semiconductor-based qubit devices it is usually accomplished using a separate mesoscopic electrometer. Here we demonstrate a simple detection scheme in which a radio frequency resonant circuit coupled to a semiconductor double quantum dot is used to probe its charge and spin states. These results demonstrate a new noninvasive technique for measuring charge and spin states in quantum dot systems without requiring a separate mesoscopic detector.
The radio-frequency superconducting single electron transistor (RF-SET) is a highly sensitive and fast electrometer operating near the quantum limit. The back-action current noise of the SET induces voltage fluctuations on the system it is coupled to, dephasing its charge states. Here we propose to study the back action of the RF-SET by means of a double quantum dot (DQD) and, an RF-SET electrostatically coupled to one of the two dots. The inelastic current through the DQD is very sensitive to the spectral density of the voltage fluctuations in the nearby environment. By properly choosing the dot size and inter-dot tunnel barrier thickness, one can cause inelastic process to dominate the transport processes. A measurement of the inelastic current through the double dot system can then be used to calculate the spectral density of noise associated with the RF-SET and hence its back action. The design, fabrication and characterization of an RF-SET/DQD system is discussed in this work. Real-time studies of electron dynamics in coupled dots are also addressed.
We report the dispersive charge-state readout of a double quantum dot in the few-electron regime using the in situ gate electrodes as sensitive detectors. We benchmark this gate sensing technique against the well established quantum point contact charge detector and find comparable performance with a bandwidth of $\ensuremath{\sim}10\text{ }\text{ }\mathrm{MHz}$ and an equivalent charge sensitivity of $\ensuremath{\sim}6.3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}3}\text{ }\text{ }e/\sqrt{\mathrm{Hz}}$. Dispersive gate sensing alleviates the burden of separate charge detectors for quantum dot systems and promises to enable readout of qubits in scaled-up arrays.
Quantum computation requires a qubit-specific measurement capability to readout the final state of individual qubits. Promising solid-state architectures use external readout electrometers but these can be replaced by a more compact readout element, an in situ gate sensor. Gate-sensing couples the qubit to a resonant circuit via a gate and probes the qubit’s radiofrequency polarizability. Here we investigate the ultimate performance of such a resonant readout scheme and the noise sources that limit its operation. We find a charge sensitivity of 37 μe Hz−1/2, the best value reported for this technique, using the example of a gate sensor strongly coupled to a double quantum dot at the corner states of a silicon nanowire transistor. We discuss the experimental factors limiting gate detection and highlight ways to optimize its sensitivity. In total, resonant gate-based readout has advantages over external electrometers both in terms of reduction of circuit elements as well as absolute charge sensitivity. Reading out the state of quantum bits is an essential requirement that any quantum computer implementation must satisfy. Gonzalez-Zalba et al. now show that in situresonant gate-based detection can be a more sensitive approach than external electrometers while reducing the qubit architecture’s complexity.