Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:0707.2946 · Applied Physics Letters

Fast single-charge sensing with a rf quantum point contact

D. J. Reilly, Charles M. Marcus, Micah P. Hanson, Arthur C. Gossard

Published Oct 15, 2007• 295 citations
arXivHTMLPDF

Abstract

We report high-bandwidth charge sensing measurements using a GaAs quantum point contact embedded in a radio frequency impedance matching circuit (rf-QPC). With the rf-QPC biased near pinch-off where it is most sensitive to charge, we demonstrate a conductance sensitivity of 5×10−6e2∕hHz−1∕2 with a bandwidth of 8MHz. Single-shot readout of a proximal few-electron double quantum dot is investigated in a mode where the rf-QPC back action is rapidly switched.

DOI
10.1063/1.2794995

Related papers

Single shot charge detection using a radio-frequency quantum point contact

Maja C. Cassidy, Andrew S. Dzurak, R. G. Clark +4 more

We report on charge sensing measurements of a GaAs semiconductor quantum dot device using a radio frequency quantum point contact (rf-QPC). The rf-QPC is fully characterized at 4K and millikelvin temperatures and found to have a bandwidth exceeding 20MHz. For single shot charge sensing, we achieve a charge sensitivity of ∼2×10−4e∕Hz referred to the neighboring dot’s charge. The rf-QPC compares favorably with rf single electron transistor electrometers and promises to be an extremely useful tool for characterizing and measuring semiconductor quantum systems on fast time scales.

arXiv:0907.1010•Applied Physics Letters•Nov 26, 2007•87 citations

Development and study of charge sensors for fast charge detection in quantum dots

Madhu Thalakulam

Charge detection at microsecond time-scales has far reaching consequences in both technology and in our understanding of electron dynamics in nanoscale devices such as quantum dots. Radio-frequency superconducting single electron transistors (RF-SET) and quantum point contacts (QPC) are ultra sensitive charge sensors operating near the quantum limit. The operation of RF-SETs outside the superconducting gap has been a topic of study; the sub-gap operation, especially in the presence of large quantum fluctuations of quasiparticles remains largely unexplored, both theoretically and experimentally. We have investigated the effects of quantum fluctuations of quasiparticles on the operation of RF-SETs for large values of the quasiparticle cotunneling parameter alpha = 8EJ/Ec, where EJ and Ec are the Josephson and charging energies. We find that, for alpha > 1, sub-gap RF-SET operation is still feasible despite quantum fluctuations that wash out quasiparticle tunneling thresholds. Such RF-SETs show linearity and signal-to-noise ratio superior to those obtained when quantum fluctuations are weak, while still demonstrating excellent charge sensitivity.\nWe have operated a QPC charge detector in a radio frequency mode that allows fast charge detection in a bandwidth of several megahertz. The noise limiting the sensitivity of the charge detector is not the noise of a secondary amplifier, but the non-equilibrium device noise of the QPC itself. The noise power averaged over a measurement bandwidth of about 10MHz around the carrier frequency is in agreement with the theory of photon-assisted shot noise. Frequency-resolved measurements, however show several significant discrepancies with the theoretical predictions. The measurement techniques developed can also be used to investigate the noise of other semiconductor nanostructures such as quantum dots in the Kondo regime.\nA study of the noise characteristics alone can not determine whether the device is operating at the quantum limit; a characterization of back action is also necessary. The inelastic current through a double quantum dot system (DQD) is sensitive to the spectral density of voltage fluctuations in its electromagnetic environment. Electrical transport studies on a DQD system electrostatically coupled to an SET shows qualitative evidence of back-action of SET. The design and fabrication of a few electron DQD device with integrated RF-SET and QPC charge sensors for the study of back action of the sensors and real-time electron dynamics in the DQD are also discussed.

•Jan 1, 2007•0 citations

Fast sensing of double-dot charge arrangement and spin state with a radio-frequency sensor quantum dot

Christian Barthel, Morten Kjærgaard, James Medford +4 more

Single-shot measurement of the charge arrangement and spin state of a double quantum dot are reported with measurement times down to 100 ns. Sensing uses radio-frequency reflectometry of a proximal quantum dot in the Coulomb blockade regime. The sensor quantum dot is up to 30 times more sensitive than a comparable quantum point-contact sensor and yields three times greater signal to noise in rf single-shot measurements. Numerical modeling is qualitatively consistent with experiment and shows that the improved sensitivity of the sensor quantum dot results from reduced lifetime broadening and screening.

arXiv:1001.3585•Physical Review B•Apr 19, 2010•202 citations

Dispersive Readout of a Few-Electron Double Quantum Dot with Fast rf Gate Sensors

James Colless, Alice Mahoney, J. M. Hornibrook +4 more

We report the dispersive charge-state readout of a double quantum dot in the few-electron regime using the in situ gate electrodes as sensitive detectors. We benchmark this gate sensing technique against the well established quantum point contact charge detector and find comparable performance with a bandwidth of $\ensuremath{\sim}10\text{ }\text{ }\mathrm{MHz}$ and an equivalent charge sensitivity of $\ensuremath{\sim}6.3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}3}\text{ }\text{ }e/\sqrt{\mathrm{Hz}}$. Dispersive gate sensing alleviates the burden of separate charge detectors for quantum dot systems and promises to enable readout of qubits in scaled-up arrays.

arXiv:1210.4645•Physical Review Letters•Jan 25, 2013•211 citations

Shot-Noise-Limited Operation of a Fast Quantum-Point-Contact Charge Sensor

Madhu Thalakulam, W. W. Xue, Pan, Feng +5 more

We have operated a quantum point contact (QPC) charge detector in a radio frequency (RF) mode that allows fast charge detection in a bandwidth of tens of megahertz. We find that the charge sensitivity of the RF-QPC is limited not by the noise of a secondary amplifier, but by non-equilibrium noise f the QPC itself. We have performed frequency-resolved measurements of the noise within a 10 MHz bandwidth around our carrier wave. When averaged over our bandwidth, we find that the noise is in good agreement with the theory of photon-assisted shot noise. Our measurements also reveal strong frequency dependence of the noise, asymmetry with respect to the carrier wave, the appearance of sharp local maxima that are correlated with mechanical degrees of freedom in the sample, and noise suppression indicative of many-body physics near the 0.7 structure.

arXiv:0708.0861•Aug 7, 2007•3 citations

Time-resolved charge detection with cross-correlation techniques

Bruno Küng, Oliver Pfäffli, Simon Gustavsson +4 more

We present time-resolved charge-sensing measurements on a GaAs double quantum dot with two proximal quantum point-contact (QPC) detectors. The QPC currents are analyzed with cross-correlation techniques, which enable us to measure dot charging and discharging rates for significantly smaller signal-to-noise ratios than required for charge detection with a single QPC. This allows us to reduce the current level in the detector and therefore the invasiveness of the detection process and may help to increase the available measurement bandwidth in noise-limited setups.

arXiv:0810.2406•Physical Review B•Jan 13, 2009•18 citations
We report high-bandwidth charge sensing measurements using a GaAs quantum point contact embedded in a radio frequency impedance matching circuit (rf-QPC). With the rf-QPC biased near pinch-off where it is most sensitive to charge, we demonstrate a conductance sensitivity of 5×10−6e2∕hHz−1∕2 with a bandwidth of 8MHz. Single-shot readout of a proximal few-electron double quantum dot is investigated in a mode where the rf-QPC back action is rapidly switched.
We report on charge sensing measurements of a GaAs semiconductor quantum dot device using a radio frequency quantum point contact (rf-QPC). The rf-QPC is fully characterized at 4K and millikelvin temperatures and found to have a bandwidth exceeding 20MHz. For single shot charge sensing, we achieve a charge sensitivity of ∼2×10−4e∕Hz referred to the neighboring dot’s charge. The rf-QPC compares favorably with rf single electron transistor electrometers and promises to be an extremely useful tool for characterizing and measuring semiconductor quantum systems on fast time scales.
Charge detection at microsecond time-scales has far reaching consequences in both technology and in our understanding of electron dynamics in nanoscale devices such as quantum dots. Radio-frequency superconducting single electron transistors (RF-SET) and quantum point contacts (QPC) are ultra sensitive charge sensors operating near the quantum limit. The operation of RF-SETs outside the superconducting gap has been a topic of study; the sub-gap operation, especially in the presence of large quantum fluctuations of quasiparticles remains largely unexplored, both theoretically and experimentally. We have investigated the effects of quantum fluctuations of quasiparticles on the operation of RF-SETs for large values of the quasiparticle cotunneling parameter alpha = 8EJ/Ec, where EJ and Ec are the Josephson and charging energies. We find that, for alpha > 1, sub-gap RF-SET operation is still feasible despite quantum fluctuations that wash out quasiparticle tunneling thresholds. Such RF-SETs show linearity and signal-to-noise ratio superior to those obtained when quantum fluctuations are weak, while still demonstrating excellent charge sensitivity.\nWe have operated a QPC charge detector in a radio frequency mode that allows fast charge detection in a bandwidth of several megahertz. The noise limiting the sensitivity of the charge detector is not the noise of a secondary amplifier, but the non-equilibrium device noise of the QPC itself. The noise power averaged over a measurement bandwidth of about 10MHz around the carrier frequency is in agreement with the theory of photon-assisted shot noise. Frequency-resolved measurements, however show several significant discrepancies with the theoretical predictions. The measurement techniques developed can also be used to investigate the noise of other semiconductor nanostructures such as quantum dots in the Kondo regime.\nA study of the noise characteristics alone can not determine whether the device is operating at the quantum limit; a characterization of back action is also necessary. The inelastic current through a double quantum dot system (DQD) is sensitive to the spectral density of voltage fluctuations in its electromagnetic environment. Electrical transport studies on a DQD system electrostatically coupled to an SET shows qualitative evidence of back-action of SET. The design and fabrication of a few electron DQD device with integrated RF-SET and QPC charge sensors for the study of back action of the sensors and real-time electron dynamics in the DQD are also discussed.
Single-shot measurement of the charge arrangement and spin state of a double quantum dot are reported with measurement times down to 100 ns. Sensing uses radio-frequency reflectometry of a proximal quantum dot in the Coulomb blockade regime. The sensor quantum dot is up to 30 times more sensitive than a comparable quantum point-contact sensor and yields three times greater signal to noise in rf single-shot measurements. Numerical modeling is qualitatively consistent with experiment and shows that the improved sensitivity of the sensor quantum dot results from reduced lifetime broadening and screening.
We report the dispersive charge-state readout of a double quantum dot in the few-electron regime using the in situ gate electrodes as sensitive detectors. We benchmark this gate sensing technique against the well established quantum point contact charge detector and find comparable performance with a bandwidth of $\ensuremath{\sim}10\text{ }\text{ }\mathrm{MHz}$ and an equivalent charge sensitivity of $\ensuremath{\sim}6.3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}3}\text{ }\text{ }e/\sqrt{\mathrm{Hz}}$. Dispersive gate sensing alleviates the burden of separate charge detectors for quantum dot systems and promises to enable readout of qubits in scaled-up arrays.
We have operated a quantum point contact (QPC) charge detector in a radio frequency (RF) mode that allows fast charge detection in a bandwidth of tens of megahertz. We find that the charge sensitivity of the RF-QPC is limited not by the noise of a secondary amplifier, but by non-equilibrium noise f the QPC itself. We have performed frequency-resolved measurements of the noise within a 10 MHz bandwidth around our carrier wave. When averaged over our bandwidth, we find that the noise is in good agreement with the theory of photon-assisted shot noise. Our measurements also reveal strong frequency dependence of the noise, asymmetry with respect to the carrier wave, the appearance of sharp local maxima that are correlated with mechanical degrees of freedom in the sample, and noise suppression indicative of many-body physics near the 0.7 structure.
We present time-resolved charge-sensing measurements on a GaAs double quantum dot with two proximal quantum point-contact (QPC) detectors. The QPC currents are analyzed with cross-correlation techniques, which enable us to measure dot charging and discharging rates for significantly smaller signal-to-noise ratios than required for charge detection with a single QPC. This allows us to reduce the current level in the detector and therefore the invasiveness of the detection process and may help to increase the available measurement bandwidth in noise-limited setups.