Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2609.26583

Preselection-Encoded Weak-Value Interferometry for Optical-Rotation Metrology

Jinyi Li, Juncheng Zheng, Yuntao Shen, Jiashu Liang, Sicheng Pan, Dongmei Li, Hengyan Wang, Wenqiang Zheng

quant-phSubmitted Sep 22, 2026• Announced Sep 23, 2026• 0 citations
arXivHTMLPDF

Abstract

Optical-rotation measurements benefit from increasing probe photon number, but their performance is often limited by detector saturation and technical noise in the optical readout. Here we introduce preselection-encoded weak-value amplification (PeWVA), in which the quantity of interest is encoded into the probe polarization before a downstream weak-value interferometer. This architecture separates the sensing interaction from the postselected readout, enabling tunable local amplification while reducing the optical power delivered to the detector. We show that PeWVA does not create additional Fisher information, but offers a practical advantage when detector dynamic range is limiting. We further analyze coherent stray light and phase fluctuations and show reduced conversion of these perturbations into equivalent rotation errors. Using an $^{87}$Rb $M_x$ atomic magnetometer, we experimentally demonstrate substantially improved magnetic-field readout under detector-constrained conditions using both transimpedance-amplified and avalanche photodiodes. The experiments also confirm reduced susceptibility to vapor-cell-induced stray light and interferometer phase modulation. These results establish PeWVA as a detector-constrained optical readout strategy with enhanced tolerance to representative interferometric perturbations.

AI Summary

The paper asks whether encoding an optical-rotation signal in the polarization preselection, before a fixed weak-value interferometer, can retain useful amplification under detector constraints while separating the sensing medium from the interferometric readout. Its preselection-encoded weak-value amplification (PeWVA) scheme applies opposite, controllable polarization rotations in two interferometer arms and postselects the outputs for photodiode intensity detection. Analytical transfer functions give a local normalized-visibility slope of approximately $1/\mathcal D$ near the nearly orthogonal operating condition, with smaller coupling $\mathcal D$ narrowing the usable range. A Fisher-information calculation including both detected ports and postselection rejection gives the same maximum $4N$ as optimized standard interferometry at fixed incident photon number $N$: postselection creates no additional information. Under an ideal detector-saturation constraint, the available information instead scales as $4N_{\mathrm{sat}}/p_s$, where $p_s$ is the accepted fraction. Experiments use an $^{87}\mathrm{Rb}$ $M_x$ magnetometer with downstream PeWVA readout. Unsaturated standard-interferometric readout gives approximately $65\,\mathrm{pT}/\sqrt{\mathrm{Hz}}$ at $0.37$ mW probe power; PeWVA gives $8.5\,\mathrm{pT}/\sqrt{\mathrm{Hz}}$ with a photodiode at $4$ mW and $2.1\,\mathrm{pT}/\sqrt{\mathrm{Hz}}$ with an avalanche photodiode at $1.4$ mW. Models and controlled tests also show reduced equivalent rotation errors from cell-induced coherent stray light and interferometer phase modulation at the selected operating points. The stated advantages are detector- and perturbation-dependent, not fundamental per-photon sensitivity gains. Amplification trades against linear range, and increasingly orthogonal selection introduces nonlinear response. Extensions to other sensors and nonclassical probes remain prospective.

Some signs of AI-generated textIncrementalMissing comparisonPossible error

Central claim may not hold: The experimental SI baseline uses θ₀ = 45°, D = 22.5°, and dark-port phase π, where the stated transfer function has zero linear rotation response, leaving its lock-in calibration and its characterization as an optimized baseline unresolved. The theoretical robustness comparison evaluates SI equivalent rotation errors by dividing by a rotation slope that vanishes at the explicitly selected operating point, invalidating the finite linearized error comparison.

Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.

Related papers

Optimal Estimation in Weak Value Amplification with a Position Pointer

Jing-Hui Huang, Jing Zhang, Jian Ge +3 more

We experimentally evaluate five estimators for weak-value amplification (WVA) using a position pointer to measure birefringence time delays. Two general approaches are considered: measuring the position shift $Δx$ and measuring the probability change $ΔP_w$ of successful postselection. Specifically, five estimators are investigated: CCD-detected fringe shift $Δx$, quadrant photodiode (PDQ) transversal voltage difference (XDIFF), and lock-in amplifier output phase $η$ (for $Δx$ measurement), as well as PDQ total output voltage (SUM) and CCD-detected average photon number $N_r$ (for $ΔP_w$ measurement). The measurement precision is characterized by the Allan deviation over a range of input laser powers $P_0$. Generally, measuring the position shift $Δx$ yields higher precision than measuring the probability change $ΔP_w$. At $P_0=0.5$~mW, corresponding to a laser-power-limited regime, direct measurement of the fringe displacement with the CCD achieves a minimum Allan deviation of $(5.30\pm0.10)\times10^{-3}$~as, approaching the corresponding photon-statistical Cramér--Rao bound (CRB). At $P_0=50$~mW, corresponding to a detector-limited regime, PDQ detection combined with lock-in demodulation provides the best precision, reaching $(1.80\pm0.06)\times10^{-3}$~as and remaining close to the corresponding CRB. These results demonstrate that the optimal readout depends on the available optical power, detector dynamic range, and technical noise, providing practical guidance for selecting readout strategies in high-precision WVA-based metrology.

quant-pharXiv:2611.00521•Nov 3, 2026•0 citations

Fisher information analysis on weak-value-amplification metrology using optical coherent states

Yingxin Liu, Lupei Qin, Xin-Qi Li

The weak-value-amplification (WVA) technique has been extensively considered and debated in the field of quantum precision measurement, largely owing to the reduced Fisher information caused by the low probability of successful postselection. In this work we show that, rather than the transverse-spatial-wave-function meter typically considered, using the optical coherent state as a meter, the WVA measurement can outperform the conventional measurement not involving the strategy of postselection. We also show that the postselection procedure involved in the WVA scheme can make a mixture of coherent states work better than a pure coherent state with identical average photon numbers. This is in contrast to the main result proved in the absence of postselection. The postselection strategy can also result in the precision of Heisenberg scaling with the photon numbers without using expensive quantum resources. The present work may stimulate further interest in postselection strategy for quantum precision measurements.

arXiv:2201.13016•Physical Review A•Aug 30, 2022•21 citations

Enhanced on-chip phase measurement by inverse weak value amplification

Meiting Song, John Steinmetz, Yi Zhang +4 more

Optical interferometry plays an essential role in precision metrology such as in gravitational wave detection, gyroscopes, and environmental sensing. Weak value amplification enables reaching the shot-noise-limit of sensitivity, which is difficult for most optical sensors, by amplifying the interferometric signal without amplifying certain technical noises. We implement a generalized form of weak value amplification on an integrated photonic platform with a multi-mode interferometer. Our results pave the way for a more sensitive, robust, and compact platform for measuring phase, which can be adapted to fields such as coherent communications and the quantum domain. In this work, we show a 7 dB signal enhancement in our weak value device over a standard Mach-Zehnder interferometer with equal detected optical power, as well as frequency measurements with 2 kHz sensitivity by adding a ring resonator.

Nature Communications•Oct 29, 2021•32 citations

Enhancing Interferometry Using Weak Value Amplification with Real Weak Values

Jing-Hui Huang, Kyle M. Jordan, Adetunmise C. Dada +2 more

We introduce an ultrasensitive interferometric protocol that combines weak value amplification (WVA) with traditional interferometry. This protocol WVA+interferometry uses weak value amplification of the relative delay between two paths to enhance interferometric sensitivity. As an example, we demonstrate a proof-of-principle experiment that achieves few-attosecond timing resolution (few nanometer path length resolution) with a double-slit interferometer using only common optical components. Since our example uses only the spatial shift of double-slit interference fringes, its precision is not limited by the timing resolution of the detectors but is instead limited by the fundamental shot noise associated with classical light and the diminished technical noise. We experimentally demonstrate that the signal-to-noise ratio can be improved by one to two orders of magnitude relative to a measurement that does not use WVA. Two key conclusions are drawn: (i) Most conventional interferometric techniques primarily rely on determining the path difference (time delay or longitudinal phase), with their precision constrained by technical noise. Our protocol offers a robust solution for minimizing the technical noise in traditional interferometry, with precision in principle approaching the shot-noise limit. (ii) Although WVA has achieved significant advancements in ultrasensitive longitudinal phase measurement, its applicability is constrained by the need for broad spectral bandwidths and high-resolution spectrometers. Contrary to previous assumptions, we demonstrate that quantum-limited WVA time delay measurements are achievable with narrow band light using real weak values. Thus, the cost-effectiveness and practicality of the proposed WVA+interferometry protocol using narrow band light broaden the scope of WVA applications. This protocol holds potential for broad applications in optical metrology, quantum optics and quantum information, biomedical imaging, and interferometric telescopes for astrophysics.

arXiv:2404.00531•Physical Review Letters•Feb 27, 2025•13 citations

Enhanced Weak-Value Amplification via Photon Recycling

Courtney Krafczyk, Andrew N. Jordan, M. E. Goggin +1 more

In a quantum-noise limited system, weak-value amplification using postselection normally does not produce more sensitive measurements than standard methods for ideal detectors: the increased weak value is compensated by the reduced power due to the small postselection probability. Here, we experimentally demonstrate recycled weak-value measurements using a pulsed light source and optical switch to enable nearly deterministic weak-value amplification of a mirror tilt. Using photon counting detectors, we demonstrate a signal improvement by a factor of 4.4±0.2 and a signal-to-noise ratio improvement of 2.10±0.06, compared to a single-pass weak-value experiment, and also compared to a conventional direct measurement of the tilt. The signal-to-noise ratio improvement could reach around six for the parameters of this experiment, assuming lower loss elements.

arXiv:2104.14393•Physical Review Letters•Jun 1, 2021•43 citations

Improving the precision of optical metrology by detecting fewer photons with biased weak measurement

Peng Yin, Wen-Hao Zhang, Liang Xu +13 more

In optical metrological protocols to measure physical quantities, it is, in principle, always beneficial to increase photon number n to improve measurement precision. However, practical constraints prevent the arbitrary increase of n due to the imperfections of a practical detector, especially when the detector response is dominated by the saturation effect. In this work, we show that a modified weak measurement protocol, namely, biased weak measurement significantly improves the precision of optical metrology in the presence of saturation effect. This method detects an ultra-small fraction of photons while maintains a considerable amount of metrological information. The biased pre-coupling leads to an additional reduction of photons in the post-selection and generates an extinction point in the spectrum distribution, which is extremely sensitive to the estimated parameter and difficult to be saturated. Therefore, the Fisher information can be persistently enhanced by increasing the photon number. In our magnetic-sensing experiment, biased weak measurement achieves precision approximately one order of magnitude better than those of previously used methods. The proposed method can be applied in various optical measurement schemes to remarkably mitigate the detector saturation effect with low-cost apparatuses.

arXiv:2103.12373•Light Science & Applications•May 17, 2021•44 citations
Optical-rotation measurements benefit from increasing probe photon number, but their performance is often limited by detector saturation and technical noise in the optical readout. Here we introduce preselection-encoded weak-value amplification (PeWVA), in which the quantity of interest is encoded into the probe polarization before a downstream weak-value interferometer. This architecture separates the sensing interaction from the postselected readout, enabling tunable local amplification while reducing the optical power delivered to the detector. We show that PeWVA does not create additional Fisher information, but offers a practical advantage when detector dynamic range is limiting. We further analyze coherent stray light and phase fluctuations and show reduced conversion of these perturbations into equivalent rotation errors. Using an 87^{87}87Rb MxM_xMx​ atomic magnetometer, we experimentally demonstrate substantially improved magnetic-field readout under detector-constrained conditions using both transimpedance-amplified and avalanche photodiodes. The experiments also confirm reduced susceptibility to vapor-cell-induced stray light and interferometer phase modulation. These results establish PeWVA as a detector-constrained optical readout strategy with enhanced tolerance to representative interferometric perturbations.
The paper asks whether encoding an optical-rotation signal in the polarization preselection, before a fixed weak-value interferometer, can retain useful amplification under detector constraints while separating the sensing medium from the interferometric readout. Its preselection-encoded weak-value amplification (PeWVA) scheme applies opposite, controllable polarization rotations in two interferometer arms and postselects the outputs for photodiode intensity detection.
Analytical transfer functions give a local normalized-visibility slope of approximately 1/D1/\mathcal D1/D near the nearly orthogonal operating condition, with smaller coupling D\mathcal DD narrowing the usable range. A Fisher-information calculation including both detected ports and postselection rejection gives the same maximum 4N4N4N as optimized standard interferometry at fixed incident photon number NNN: postselection creates no additional information. Under an ideal detector-saturation constraint, the available information instead scales as 4Nsat/ps4N_{\mathrm{sat}}/p_s4Nsat​/ps​, where psp_sps​ is the accepted fraction.
Experiments use an 87Rb^{87}\mathrm{Rb}87Rb MxM_xMx​ magnetometer with downstream PeWVA readout. Unsaturated standard-interferometric readout gives approximately 65 pT/Hz65\,\mathrm{pT}/\sqrt{\mathrm{Hz}}65pT/Hz​ at 0.370.370.37 mW probe power; PeWVA gives 8.5 pT/Hz8.5\,\mathrm{pT}/\sqrt{\mathrm{Hz}}8.5pT/Hz​ with a photodiode at 444 mW and 2.1 pT/Hz2.1\,\mathrm{pT}/\sqrt{\mathrm{Hz}}2.1pT/Hz​ with an avalanche photodiode at 1.41.41.4 mW. Models and controlled tests also show reduced equivalent rotation errors from cell-induced coherent stray light and interferometer phase modulation at the selected operating points.
The stated advantages are detector- and perturbation-dependent, not fundamental per-photon sensitivity gains. Amplification trades against linear range, and increasingly orthogonal selection introduces nonlinear response. Extensions to other sensors and nonclassical probes remain prospective.
We experimentally evaluate five estimators for weak-value amplification (WVA) using a position pointer to measure birefringence time delays. Two general approaches are considered: measuring the position shift ΔxΔxΔx and measuring the probability change ΔPwΔP_wΔPw​ of successful postselection. Specifically, five estimators are investigated: CCD-detected fringe shift ΔxΔxΔx, quadrant photodiode (PDQ) transversal voltage difference (XDIFF), and lock-in amplifier output phase ηηη (for ΔxΔxΔx measurement), as well as PDQ total output voltage (SUM) and CCD-detected average photon number NrN_rNr​ (for ΔPwΔP_wΔPw​ measurement). The measurement precision is characterized by the Allan deviation over a range of input laser powers P0P_0P0​. Generally, measuring the position shift ΔxΔxΔx yields higher precision than measuring the probability change ΔPwΔP_wΔPw​. At P0=0.5P_0=0.5P0​=0.5~mW, corresponding to a laser-power-limited regime, direct measurement of the fringe displacement with the CCD achieves a minimum Allan deviation of (5.30±0.10)×10−3(5.30\pm0.10)\times10^{-3}(5.30±0.10)×10−3~as, approaching the corresponding photon-statistical Cramér--Rao bound (CRB). At P0=50P_0=50P0​=50~mW, corresponding to a detector-limited regime, PDQ detection combined with lock-in demodulation provides the best precision, reaching (1.80±0.06)×10−3(1.80\pm0.06)\times10^{-3}(1.80±0.06)×10−3~as and remaining close to the corresponding CRB. These results demonstrate that the optimal readout depends on the available optical power, detector dynamic range, and technical noise, providing practical guidance for selecting readout strategies in high-precision WVA-based metrology.
The weak-value-amplification (WVA) technique has been extensively considered and debated in the field of quantum precision measurement, largely owing to the reduced Fisher information caused by the low probability of successful postselection. In this work we show that, rather than the transverse-spatial-wave-function meter typically considered, using the optical coherent state as a meter, the WVA measurement can outperform the conventional measurement not involving the strategy of postselection. We also show that the postselection procedure involved in the WVA scheme can make a mixture of coherent states work better than a pure coherent state with identical average photon numbers. This is in contrast to the main result proved in the absence of postselection. The postselection strategy can also result in the precision of Heisenberg scaling with the photon numbers without using expensive quantum resources. The present work may stimulate further interest in postselection strategy for quantum precision measurements.
Optical interferometry plays an essential role in precision metrology such as in gravitational wave detection, gyroscopes, and environmental sensing. Weak value amplification enables reaching the shot-noise-limit of sensitivity, which is difficult for most optical sensors, by amplifying the interferometric signal without amplifying certain technical noises. We implement a generalized form of weak value amplification on an integrated photonic platform with a multi-mode interferometer. Our results pave the way for a more sensitive, robust, and compact platform for measuring phase, which can be adapted to fields such as coherent communications and the quantum domain. In this work, we show a 7 dB signal enhancement in our weak value device over a standard Mach-Zehnder interferometer with equal detected optical power, as well as frequency measurements with 2 kHz sensitivity by adding a ring resonator.
We introduce an ultrasensitive interferometric protocol that combines weak value amplification (WVA) with traditional interferometry. This protocol WVA+interferometry uses weak value amplification of the relative delay between two paths to enhance interferometric sensitivity. As an example, we demonstrate a proof-of-principle experiment that achieves few-attosecond timing resolution (few nanometer path length resolution) with a double-slit interferometer using only common optical components. Since our example uses only the spatial shift of double-slit interference fringes, its precision is not limited by the timing resolution of the detectors but is instead limited by the fundamental shot noise associated with classical light and the diminished technical noise. We experimentally demonstrate that the signal-to-noise ratio can be improved by one to two orders of magnitude relative to a measurement that does not use WVA. Two key conclusions are drawn: (i) Most conventional interferometric techniques primarily rely on determining the path difference (time delay or longitudinal phase), with their precision constrained by technical noise. Our protocol offers a robust solution for minimizing the technical noise in traditional interferometry, with precision in principle approaching the shot-noise limit. (ii) Although WVA has achieved significant advancements in ultrasensitive longitudinal phase measurement, its applicability is constrained by the need for broad spectral bandwidths and high-resolution spectrometers. Contrary to previous assumptions, we demonstrate that quantum-limited WVA time delay measurements are achievable with narrow band light using real weak values. Thus, the cost-effectiveness and practicality of the proposed WVA+interferometry protocol using narrow band light broaden the scope of WVA applications. This protocol holds potential for broad applications in optical metrology, quantum optics and quantum information, biomedical imaging, and interferometric telescopes for astrophysics.
In a quantum-noise limited system, weak-value amplification using postselection normally does not produce more sensitive measurements than standard methods for ideal detectors: the increased weak value is compensated by the reduced power due to the small postselection probability. Here, we experimentally demonstrate recycled weak-value measurements using a pulsed light source and optical switch to enable nearly deterministic weak-value amplification of a mirror tilt. Using photon counting detectors, we demonstrate a signal improvement by a factor of 4.4±0.2 and a signal-to-noise ratio improvement of 2.10±0.06, compared to a single-pass weak-value experiment, and also compared to a conventional direct measurement of the tilt. The signal-to-noise ratio improvement could reach around six for the parameters of this experiment, assuming lower loss elements.
In optical metrological protocols to measure physical quantities, it is, in principle, always beneficial to increase photon number n to improve measurement precision. However, practical constraints prevent the arbitrary increase of n due to the imperfections of a practical detector, especially when the detector response is dominated by the saturation effect. In this work, we show that a modified weak measurement protocol, namely, biased weak measurement significantly improves the precision of optical metrology in the presence of saturation effect. This method detects an ultra-small fraction of photons while maintains a considerable amount of metrological information. The biased pre-coupling leads to an additional reduction of photons in the post-selection and generates an extinction point in the spectrum distribution, which is extremely sensitive to the estimated parameter and difficult to be saturated. Therefore, the Fisher information can be persistently enhanced by increasing the photon number. In our magnetic-sensing experiment, biased weak measurement achieves precision approximately one order of magnitude better than those of previously used methods. The proposed method can be applied in various optical measurement schemes to remarkably mitigate the detector saturation effect with low-cost apparatuses.