Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2609.09571

Momentum-resolved magnetic noise spectroscopy using ensembles of diamond quantum sensors

Zeeshawn Kazi, Kai-Hung Cheng, Jared Rovny, Nathalie P. de Leon

quant-phcond-mat.mtrl-sciSubmitted Sep 9, 2026• Announced Sep 10, 2026• 0 citations• Revised Oct 4, 2026 (v2)
v1 · Sep 9, 2026v2 · Oct 4, 2026
arXivHTMLPDF

Abstract

Spatiotemporal fluctuations across multiple scales govern and characterize the emergent properties, phase boundaries, and low-energy excitations of strongly correlated matter. However, capturing these dynamics has remained a major experimental challenge, as conventional probes typically offer either high spatial or temporal resolution, but not both simultaneously. Here, we leverage high-fidelity wide-field imaging of dense diamond nitrogen vacancy center ensembles to measure the momentum and frequency power spectral density of magnetic fluctuations. To access spatial wavevectors below the diffraction limit, we tune the sensing volume continuously through optical depletion. This approach enables study of equilibrium and driven fluctuations across three orders of magnitude in spatial scale and tunable frequency bands, providing a direct means to map low-energy, long-wavelength fluctuations in correlated systems.

Related papers

Massively Multiplexed Nanoscale Magnetometry with Diamond Quantum Sensors

Kai-Hung Cheng, Zeeshawn Kazi, Jared Rovny +4 more

Single nitrogen vacancy (NV) centers in diamond have been used extensively for high-sensitivity nanoscale sensing, but conventional approaches use confocal microscopy to measure individual centers sequentially, limiting throughput and access to nonlocal physical properties, where simultaneous, high-fidelity measurement of multiple centers is required. Here, we design and implement a multiplexed NV sensing platform that allows us to read out many single NV centers simultaneously using a low-noise camera. Using this platform, we coherently manipulate and read out the spin states of hundreds of individual NV centers in parallel, achieving comparable magnetic field sensitivity to confocal measurements. We also implement a parallelized version of spin-to-charge-conversion readout for low NV center spin state readout noise and use it to demonstrate multiplexed covariance magnetometry, in which we measure ten two-point magnetic field correlators from five NV centers simultaneously. From these measurements, we demonstrate the quantitative reconstruction of spatially varying magnetic correlations arising from a current-carrying wire. The number of correlators we can measure is limited only by the available laser power, opening the door to massively multiplexed covariance magnetometry. In contrast to scanning probes for imaging spatially varying magnetic fields, our approach measures the temporal dynamics of the magnetic field at many precisely defined positions simultaneously, from which the local noise spectrum and nonlocal properties such as correlation functions can be computed. This high-fidelity readout platform will find immediate applications in studying condensed matter phenomena that are characterized by the noise spectrum or correlation functions, including quantum phase transitions, dynamics far from equilibrium, magnetic order, and correlated electron phenomena.

arXiv:2408.11666•Physical Review X•May 22, 2025•16 citations

Nanoscale covariance magnetometry with diamond quantum sensors

Jared Rovny, Zhiyang Yuan, Mattias Fitzpatrick +6 more

Nitrogen vacancy (NV) centers in diamond are atom-scale defects that can be used to sense magnetic fields with high sensitivity and spatial resolution. Typically, the magnetic field is measured by averaging sequential measurements of single NV centers, or by spatial averaging over ensembles of many NV centers, which provides mean values that contain no nonlocal information about the relationship between two points separated in space or time. Here, we propose and implement a sensing modality whereby two or more NV centers are measured simultaneously, and we extract temporal and spatial correlations in their signals that would otherwise be inaccessible. We demonstrate measurements of correlated applied noise using spin-to-charge readout of two NV centers and implement a spectral reconstruction protocol for disentangling local and nonlocal noise sources.

arXiv:2209.08703•Science•Dec 22, 2022•75 citations

Nanoscale magnetometry via collective many-body dynamics in diamond

Haoyang Gao, Piotr Put, Nathaniel T. Leitao +9 more

Many-body dynamics constitutes a promising approach for creating correlations between quantum particles which can be used for applications in sensing and metrology. However, utilizing this potential for substantial gains in practical settings is a challenging task with only a very few applications realized to date. Here, we demonstrate an approach to nanoscale magnetic sensing enabled by strongly interacting electronic spins in a room temperature solid. By coherently controlling collective many-body dynamics of a dipolar ensemble of $\sim 10^4$ nitrogen-vacancy (NV) centres in diamond with pulsed magnetic field gradients, we demonstrate practical metrological gain up to $7.9(2)\,\mathrm{dB}$ for magnetic signal detection and $8.8(3)\,\mathrm{dB}$ for magnetic noise sensing, fully accounting for experimental overheads. Finally, we combine these methods to demonstrate a momentum-space-resolved sensing modality that enables detection of spatially correlated magnetic noise at continuously tunable length scales down to 50 nanometers. These observations open the door toward practical applications of interaction-enhanced quantum sensors for nanoscale biological imaging and material characterization.

quant-pharXiv:2609.03039•Sep 4, 2026•0 citations

High-resolution and wide-frequency-range magnetic spectroscopy with solid-state spin ensembles

Zechuan Yin, Justin J. Welter, Connor Hart +2 more

Quantum systems composed of solid-state electronic spins can be sensitive detectors of narrowband magnetic fields. A prominent example is the nitrogen-vacancy (NV) center in diamond, which has been employed for magnetic spectroscopy with high spatial and spectral resolution. However, NV-diamond spectroscopy protocols are typically based on dynamical decoupling sequences, which are limited to low-frequency signals ( ≲ 20 MHz) due to the technical requirements on microwave (MW) pulses used to manipulate NV electronic spins. In this work, we experimentally demonstrate a high-resolution magnetic spectroscopy protocol that integrates a quantum frequency mixing (QFM) effect in a dense NV ensemble with coherently averaged synchronized readout (CASR) to provide both a wide range of signal frequency detection and sub-Hz spectral resolution. We assess the sensitivity of this QFM-CASR protocol across a frequency range of 10 MHz to 4 GHz. By measuring the spectra of multi-frequency signals near 0.6, 2.4 and 4 GHz, we demonstrate sub-Hz spectral resolution with a nT-scale noise floor for the target signal, and precise phase measurement with error < 1 ∘ . Compared to state-of-the-art NV-diamond techniques for high-resolution magnetic spectroscopy, the QFM-CASR protocol extends the signal frequency range by more than an order of magnitude, enabling applications in radio frequency (RF) and MW signal microscopy and analysis, as well as tesla-scale nuclear magnetic resonance (NMR) spectroscopy of small samples.

npj Quantum Information•Dec 3, 2025•2 citations

Multi-qubit nanoscale sensing with entanglement as a resource

Jared Rovny, Shimon Kolkowitz, Nathalie P. de Leon

Nitrogen vacancy (NV) centers in diamond are widely deployed as local magnetic sensors, using coherent, single qubit control to measure both time-averaged fields and noise with nanoscale spatial resolution. Moving beyond single qubits to multi-qubit control enables new sensing modalities such as measuring nonlocal spatiotemporal correlators, or using entangled states to improve measurement sensitivity. Here, we describe protocols to use optically unresolved NV center pairs and nuclear spins as multi-qubit sensors for measuring correlated noise, enabling covariance magnetometry at nanometer length scales. For NV centers that are optically unresolved but have spectrally resolved spin transitions, we implement a phase-cycling protocol that disambiguates magnetic correlations from variance fluctuations by alternating the relative spin orientations of the two NV centers. For NV centers that are both optically and spectrally unresolved, we leverage the presence of a third qubit, a 13C nucleus that is strongly coupled to one of the NV centers, to effect coherent single-NV spin flips and enable a similar phase-cycling protocol. For length scales around 10 nm, we create maximally entangled Bell states through dipole-dipole coupling between two NV centers, and use these entangled states to directly read out the magnetic field correlation, rather than reconstructing it from independent measurements of unentangled NV centers. Importantly, this changes the scaling of sensitivity with readout noise from quadratic to linear. For conventional off-resonant readout of the NV center spin state (for which the readout noise is roughly 30 times the quantum projection limit), this results in a dramatic sensitivity improvement. Finally, we demonstrate methods for the detection of high spatial- and temporal-resolution correlators with pairs of strongly interacting NV centers.

arXiv:2504.12533•Apr 16, 2025•0 citations

High-resolution, Wide-frequency-range Magnetic Spectroscopy with Solid-state Spin Ensembles

Ronald Lee Walsworth, Zechuan Yin, Justin J. Welter +2 more

Abstract Quantum systems composed of solid-state electronic spins can be sensitive detectors of narrowband magnetic fields. A prominent example is the nitrogen-vacancy (NV) center in diamond, which has been employed for magnetic spectroscopy with high spatial and spectral resolution. However, NV-diamond spectroscopy protocols are typically based on dynamical decoupling sequences, which are limited to low-frequency signals (≲ 20 MHz) due to the technical requirements on microwave (MW) pulses used to manipulate NV electronic spins. In this work, we experimentally demonstrate a high-resolution magnetic spectroscopy protocol that integrates a quantum frequency mixing (QFM) effect in a dense NV ensemble with coherently averaged synchronized readout (CASR) to provide both a wide range of signal frequency detection and sub-Hz spectral resolution. We assess the sensitivity of this QFM-CASR protocol across a frequency range of 10 MHz to 4 GHz. By measuring the spectra of multi-frequency signals near 0.6, 2.4 and 4 GHz, we demonstrate sub-Hz spectral resolution with a nT-scale noise floor for the target signal, and precise phase measurement with error <1°. Compared to state-of-the-art NV-diamond techniques for narrowband magnetic spectroscopy, the QFM-CASR protocol greatly extends the detectable frequency range, enabling applications in high-frequency radio frequency (RF) and MW signal microscopy and analysis, as well as tesla-scale nuclear magnetic resonance (NMR) spectroscopy of small samples.

•Jan 24, 2025•0 citations
Spatiotemporal fluctuations across multiple scales govern and characterize the emergent properties, phase boundaries, and low-energy excitations of strongly correlated matter. However, capturing these dynamics has remained a major experimental challenge, as conventional probes typically offer either high spatial or temporal resolution, but not both simultaneously. Here, we leverage high-fidelity wide-field imaging of dense diamond nitrogen vacancy center ensembles to measure the momentum and frequency power spectral density of magnetic fluctuations. To access spatial wavevectors below the diffraction limit, we tune the sensing volume continuously through optical depletion. This approach enables study of equilibrium and driven fluctuations across three orders of magnitude in spatial scale and tunable frequency bands, providing a direct means to map low-energy, long-wavelength fluctuations in correlated systems.
Single nitrogen vacancy (NV) centers in diamond have been used extensively for high-sensitivity nanoscale sensing, but conventional approaches use confocal microscopy to measure individual centers sequentially, limiting throughput and access to nonlocal physical properties, where simultaneous, high-fidelity measurement of multiple centers is required. Here, we design and implement a multiplexed NV sensing platform that allows us to read out many single NV centers simultaneously using a low-noise camera. Using this platform, we coherently manipulate and read out the spin states of hundreds of individual NV centers in parallel, achieving comparable magnetic field sensitivity to confocal measurements. We also implement a parallelized version of spin-to-charge-conversion readout for low NV center spin state readout noise and use it to demonstrate multiplexed covariance magnetometry, in which we measure ten two-point magnetic field correlators from five NV centers simultaneously. From these measurements, we demonstrate the quantitative reconstruction of spatially varying magnetic correlations arising from a current-carrying wire. The number of correlators we can measure is limited only by the available laser power, opening the door to massively multiplexed covariance magnetometry. In contrast to scanning probes for imaging spatially varying magnetic fields, our approach measures the temporal dynamics of the magnetic field at many precisely defined positions simultaneously, from which the local noise spectrum and nonlocal properties such as correlation functions can be computed. This high-fidelity readout platform will find immediate applications in studying condensed matter phenomena that are characterized by the noise spectrum or correlation functions, including quantum phase transitions, dynamics far from equilibrium, magnetic order, and correlated electron phenomena.
Nitrogen vacancy (NV) centers in diamond are atom-scale defects that can be used to sense magnetic fields with high sensitivity and spatial resolution. Typically, the magnetic field is measured by averaging sequential measurements of single NV centers, or by spatial averaging over ensembles of many NV centers, which provides mean values that contain no nonlocal information about the relationship between two points separated in space or time. Here, we propose and implement a sensing modality whereby two or more NV centers are measured simultaneously, and we extract temporal and spatial correlations in their signals that would otherwise be inaccessible. We demonstrate measurements of correlated applied noise using spin-to-charge readout of two NV centers and implement a spectral reconstruction protocol for disentangling local and nonlocal noise sources.
Many-body dynamics constitutes a promising approach for creating correlations between quantum particles which can be used for applications in sensing and metrology. However, utilizing this potential for substantial gains in practical settings is a challenging task with only a very few applications realized to date. Here, we demonstrate an approach to nanoscale magnetic sensing enabled by strongly interacting electronic spins in a room temperature solid. By coherently controlling collective many-body dynamics of a dipolar ensemble of ∼104\sim 10^4∼104 nitrogen-vacancy (NV) centres in diamond with pulsed magnetic field gradients, we demonstrate practical metrological gain up to 7.9(2) dB7.9(2)\,\mathrm{dB}7.9(2)dB for magnetic signal detection and 8.8(3) dB8.8(3)\,\mathrm{dB}8.8(3)dB for magnetic noise sensing, fully accounting for experimental overheads. Finally, we combine these methods to demonstrate a momentum-space-resolved sensing modality that enables detection of spatially correlated magnetic noise at continuously tunable length scales down to 50 nanometers. These observations open the door toward practical applications of interaction-enhanced quantum sensors for nanoscale biological imaging and material characterization.
Quantum systems composed of solid-state electronic spins can be sensitive detectors of narrowband magnetic fields. A prominent example is the nitrogen-vacancy (NV) center in diamond, which has been employed for magnetic spectroscopy with high spatial and spectral resolution. However, NV-diamond spectroscopy protocols are typically based on dynamical decoupling sequences, which are limited to low-frequency signals ( ≲ 20 MHz) due to the technical requirements on microwave (MW) pulses used to manipulate NV electronic spins. In this work, we experimentally demonstrate a high-resolution magnetic spectroscopy protocol that integrates a quantum frequency mixing (QFM) effect in a dense NV ensemble with coherently averaged synchronized readout (CASR) to provide both a wide range of signal frequency detection and sub-Hz spectral resolution. We assess the sensitivity of this QFM-CASR protocol across a frequency range of 10 MHz to 4 GHz. By measuring the spectra of multi-frequency signals near 0.6, 2.4 and 4 GHz, we demonstrate sub-Hz spectral resolution with a nT-scale noise floor for the target signal, and precise phase measurement with error < 1 ∘ . Compared to state-of-the-art NV-diamond techniques for high-resolution magnetic spectroscopy, the QFM-CASR protocol extends the signal frequency range by more than an order of magnitude, enabling applications in radio frequency (RF) and MW signal microscopy and analysis, as well as tesla-scale nuclear magnetic resonance (NMR) spectroscopy of small samples.
Nitrogen vacancy (NV) centers in diamond are widely deployed as local magnetic sensors, using coherent, single qubit control to measure both time-averaged fields and noise with nanoscale spatial resolution. Moving beyond single qubits to multi-qubit control enables new sensing modalities such as measuring nonlocal spatiotemporal correlators, or using entangled states to improve measurement sensitivity. Here, we describe protocols to use optically unresolved NV center pairs and nuclear spins as multi-qubit sensors for measuring correlated noise, enabling covariance magnetometry at nanometer length scales. For NV centers that are optically unresolved but have spectrally resolved spin transitions, we implement a phase-cycling protocol that disambiguates magnetic correlations from variance fluctuations by alternating the relative spin orientations of the two NV centers. For NV centers that are both optically and spectrally unresolved, we leverage the presence of a third qubit, a 13C nucleus that is strongly coupled to one of the NV centers, to effect coherent single-NV spin flips and enable a similar phase-cycling protocol. For length scales around 10 nm, we create maximally entangled Bell states through dipole-dipole coupling between two NV centers, and use these entangled states to directly read out the magnetic field correlation, rather than reconstructing it from independent measurements of unentangled NV centers. Importantly, this changes the scaling of sensitivity with readout noise from quadratic to linear. For conventional off-resonant readout of the NV center spin state (for which the readout noise is roughly 30 times the quantum projection limit), this results in a dramatic sensitivity improvement. Finally, we demonstrate methods for the detection of high spatial- and temporal-resolution correlators with pairs of strongly interacting NV centers.
Abstract Quantum systems composed of solid-state electronic spins can be sensitive detectors of narrowband magnetic fields. A prominent example is the nitrogen-vacancy (NV) center in diamond, which has been employed for magnetic spectroscopy with high spatial and spectral resolution. However, NV-diamond spectroscopy protocols are typically based on dynamical decoupling sequences, which are limited to low-frequency signals (≲ 20 MHz) due to the technical requirements on microwave (MW) pulses used to manipulate NV electronic spins. In this work, we experimentally demonstrate a high-resolution magnetic spectroscopy protocol that integrates a quantum frequency mixing (QFM) effect in a dense NV ensemble with coherently averaged synchronized readout (CASR) to provide both a wide range of signal frequency detection and sub-Hz spectral resolution. We assess the sensitivity of this QFM-CASR protocol across a frequency range of 10 MHz to 4 GHz. By measuring the spectra of multi-frequency signals near 0.6, 2.4 and 4 GHz, we demonstrate sub-Hz spectral resolution with a nT-scale noise floor for the target signal, and precise phase measurement with error <1°. Compared to state-of-the-art NV-diamond techniques for narrowband magnetic spectroscopy, the QFM-CASR protocol greatly extends the detectable frequency range, enabling applications in high-frequency radio frequency (RF) and MW signal microscopy and analysis, as well as tesla-scale nuclear magnetic resonance (NMR) spectroscopy of small samples.