Massively Multiplexed Nanoscale Magnetometry with Diamond Quantum Sensors

Kai-Hung Cheng, Zeeshawn Kazi, Jared Rovny, Bichen Zhang, Lila S. Nassar, Jeff D. Thompson, Nathalie P. de Leon

Published May 22, 2025• 16 citations
arXivHTMLPDF

Abstract

Single nitrogen vacancy (NV) centers in diamond have been used extensively for high-sensitivity nanoscale sensing, but conventional approaches use confocal microscopy to measure individual centers sequentially, limiting throughput and access to nonlocal physical properties, where simultaneous, high-fidelity measurement of multiple centers is required. Here, we design and implement a multiplexed NV sensing platform that allows us to read out many single NV centers simultaneously using a low-noise camera. Using this platform, we coherently manipulate and read out the spin states of hundreds of individual NV centers in parallel, achieving comparable magnetic field sensitivity to confocal measurements. We also implement a parallelized version of spin-to-charge-conversion readout for low NV center spin state readout noise and use it to demonstrate multiplexed covariance magnetometry, in which we measure ten two-point magnetic field correlators from five NV centers simultaneously. From these measurements, we demonstrate the quantitative reconstruction of spatially varying magnetic correlations arising from a current-carrying wire. The number of correlators we can measure is limited only by the available laser power, opening the door to massively multiplexed covariance magnetometry. In contrast to scanning probes for imaging spatially varying magnetic fields, our approach measures the temporal dynamics of the magnetic field at many precisely defined positions simultaneously, from which the local noise spectrum and nonlocal properties such as correlation functions can be computed. This high-fidelity readout platform will find immediate applications in studying condensed matter phenomena that are characterized by the noise spectrum or correlation functions, including quantum phase transitions, dynamics far from equilibrium, magnetic order, and correlated electron phenomena.

DOI
10.1103/t8fz-3tzs

Related papers

Nanoscale covariance magnetometry with diamond quantum sensors

Jared Rovny, Zhiyang Yuan, Mattias Fitzpatrick +6 more

Nitrogen vacancy (NV) centers in diamond are atom-scale defects that can be used to sense magnetic fields with high sensitivity and spatial resolution. Typically, the magnetic field is measured by averaging sequential measurements of single NV centers, or by spatial averaging over ensembles of many NV centers, which provides mean values that contain no nonlocal information about the relationship between two points separated in space or time. Here, we propose and implement a sensing modality whereby two or more NV centers are measured simultaneously, and we extract temporal and spatial correlations in their signals that would otherwise be inaccessible. We demonstrate measurements of correlated applied noise using spin-to-charge readout of two NV centers and implement a spectral reconstruction protocol for disentangling local and nonlocal noise sources.

arXiv:2209.08703•Science•Dec 22, 2022•75 citations

Multi-qubit nanoscale sensing with entanglement as a resource

Jared Rovny, Shimon Kolkowitz, Nathalie P. de Leon

Nitrogen vacancy (NV) centers in diamond are widely deployed as local magnetic sensors, using coherent, single qubit control to measure both time-averaged fields and noise with nanoscale spatial resolution. Moving beyond single qubits to multi-qubit control enables new sensing modalities such as measuring nonlocal spatiotemporal correlators, or using entangled states to improve measurement sensitivity. Here, we describe protocols to use optically unresolved NV center pairs and nuclear spins as multi-qubit sensors for measuring correlated noise, enabling covariance magnetometry at nanometer length scales. For NV centers that are optically unresolved but have spectrally resolved spin transitions, we implement a phase-cycling protocol that disambiguates magnetic correlations from variance fluctuations by alternating the relative spin orientations of the two NV centers. For NV centers that are both optically and spectrally unresolved, we leverage the presence of a third qubit, a 13C nucleus that is strongly coupled to one of the NV centers, to effect coherent single-NV spin flips and enable a similar phase-cycling protocol. For length scales around 10 nm, we create maximally entangled Bell states through dipole-dipole coupling between two NV centers, and use these entangled states to directly read out the magnetic field correlation, rather than reconstructing it from independent measurements of unentangled NV centers. Importantly, this changes the scaling of sensitivity with readout noise from quadratic to linear. For conventional off-resonant readout of the NV center spin state (for which the readout noise is roughly 30 times the quantum projection limit), this results in a dramatic sensitivity improvement. Finally, we demonstrate methods for the detection of high spatial- and temporal-resolution correlators with pairs of strongly interacting NV centers.

arXiv:2504.12533•Apr 16, 2025•0 citations

Scalable Parallel Measurement of Individual Nitrogen-Vacancy Centers

Matthew Carl Cambria, Saroj B. Chand, Caitlin Mary Reiter +1 more

The nitrogen-vacancy (NV) center in diamond is a solid-state spin defect that has been widely adopted for quantum sensing and quantum information processing applications. Typically, experiments are performed either with a single isolated NV center or with an unresolved ensemble of many NV centers, resulting in a trade-off between measurement speed and spatial resolution or control over individual defects. In this work, we introduce an experimental platform that bypasses this trade-off by addressing multiple optically resolved NV centers in parallel. We perform charge- and spin-state manipulations selectively on multiple NV centers from within a larger set, and we manipulate and measure the electronic spin states of over 100 NV centers in parallel. We show that the high signal-to-noise ratio of the measurements enables the detection of shot-to-shot pairwise correlations between the spin states of 108 NV centers, corresponding to the simultaneous measurement of 5778 unique correlation coefficients. We discuss how our platform can be scaled to parallel experiments with thousands of individually resolved NV centers. These results enable parallelized high-throughput sensing experiments that retain the spatial resolution of single defects and will, thereby, help to unlock advances in applications such as single-molecule NMR and characterization of integrated circuits. In addition, our approach to multiplexing provides a natural platform for the application of recently developed correlated sensing techniques.

arXiv:2408.11715•Physical Review X•May 16, 2025•19 citations

Novel Magnetic-Sensing Modalities with Nitrogen-Vacancy Centers in Diamond

Huijie Zheng, Arne Wickenbrock, Georgios Chatzidrosos +16 more

In modern-day quantum metrology, quantum sensors are widely employed to detect weak magnetic fields or nanoscale signals. Quantum devices, exploiting quantum coherence, are inevitably connected to physical constants and can achieve accuracy, repeatability, and precision approaching fundamental limits. As a result, these sensors have shown utility in a wide range of research domains spanning both science and technology. A rapidly emerging quantum sensing platform employs atomic-scale defects in crystals. In particular, magnetometry using nitrogen-vacancy (NV) color centers in diamond has garnered increasing interest. NV systems possess a combination of remarkable properties, optical addressability, long coherence times, and biocompatibility. Sensors based on NV centers excel in spatial resolution and magnetic sensitivity. These diamond-based sensors promise comparable combination of high spatial resolution and magnetic sensitivity without cryogenic operation. The above properties of NV magnetometers promise increasingly integrated quantum measurement technology, as a result, they have been extensively developed with various protocols and find use in numerous applications spanning materials characterization, nuclear magnetic resonance (NMR), condensed matter physics, paleomagnetism, neuroscience and living systems biology, and industrial vector magnetometry. In this chapter, NV centers are explored for magnetic sensing in a number of contexts. In general, we introduce novel regimes for magnetic-field probes with NV ensembles. Specifically, NV centers are developed for sensitive magnetometers for applications where microwaves (MWs) are prohibitively invasive and operations need to be carried out under zero ambient magnetic field. The primary goal of our discussion is to improve the utility of these NV center-based magnetometers.

IntechOpen eBooks•Feb 8, 2021•1 citation

Nitrogen Vacancy Centers in Diamond for Quantum Biosensing: Magnetometry Techniques, Platforms and Applications

Sirsendu Ghosal, Umakant Prajapati, Sachin Negi +3 more

Quantum sensing using nitrogen-vacancy (NV) centers in diamond has emerged as a powerful platform for detecting ultra-low magnetic fields under ambient conditions. Owing to their long spin coherence times, optical addressability, and compatibility with aqueous environments, it has found widespread applications in biosensing and bio-imaging. This review presents the fundamental principles and recent advances in NV-based quantum magnetometry for biosensing applications, with a particular focus on measurements in aqueous medium and at cellular and molecular length scales. We discuss the underlying spin physics of NV centers and highlight two primary detection modalities: optically detected magnetic resonance (ODMR) and T1 relaxometry-based sensing and how these approaches aids in the detection of both static magnetic fields and dynamic magnetic noise arising from biological processes. The review explores key application areas, including nanoscale nuclear magnetic resonance (NMR), monitoring of neural activity, detection of abnormal or rogue cells using NV-based platforms etc. In addition, strategies for enhancing sensitivity, such as surface functionalization of nanodiamonds, femtosecond (fs) laser-written photonic structures, and integration with microfluidic and lab-on-chip systems have also been discussed in depth. We also address the critical challenges, including surface-induced decoherence, charge-state instability, and signal-to-noise limitations in biofluids associated with NV-based biosensing applications. Finally, we outline future prospects, highlighting how NV-based magnetic biosensing provides a promising pathway for translating quantum sensing technologies into practical biomedical applications.

quant-pharXiv:2609.04733•Sep 7, 2026

New Quantum Sensing Modalities of Nitrogen-Vacancy Centers

Qiu, Ziwei

The recent decade has witnessed exciting developments in quantum science and technology. Quantum sensing is a rapidly growing branch, which exploits the fragility of quantum systems to detect small external signals. The extreme control at the single-atom level and the remarkably long coherence time of engineered quantum systems enable unprecedented sensitivity and precision, beating the performance of classical techniques. The nitrogen-vacancy (NV) center in diamond is one of the most promising quantum sensors. Its unique advantages have attracted considerable attention, including a long spin coherence time throughout a broad temperature range, nanoscale resolution limited by the sensor-sample distance, convenient optical control of its spin states and remarkably versatile sensing capabilities. Its properties are well studied under a bias magnetic field oriented along its quantization axis. However, its sensing capabilities in the presence of an off-axis magnetic field are much less explored. My research aims to unlock the full potential of NV quantum sensor by developing new sensing modalities under a magnetic field acting perpendicular to the NV axis, and furthermore, integrating them into a scanning probe microscope. In this dissertation, I will report our progress toward building a scanning NV multimodal quantum imaging platform, which will open up exciting opportunities in measuring nanoscale phenomena. The first chapter provides an introduction to the background of quantum sensing with NV centers, followed by a discussion on its basic properties and established sensing techniques. The second and third chapters are dedicated to two experiments performed under a perpendicular magnetic field where traditional NV magnetometry based on the Zeeman effect fails. In the second chapter, I will introduce a new sensing strategy that uses the entanglement between the electron and nuclear spins to restore the magnetic field sensitivity under this unfavored condition. This allows us to sense small changes in the magnetic field angle relative to the NV axis, and to detect anisotropic magnetic noise in the local environment. In the third chapter, I will present our latest development of scanning NV electrometry, where a single NV at the apex of a diamond scanning probe images external alternating (AC) and direct (DC) electric fields with sub-100 nm resolution. In the last chapter, I will discuss our efforts on four experiments that were left unfinished. I will present the results we have achieved, analyze the challenges that we faced and propose potential solutions to overcome them.

•Jan 1, 2022•0 citations
Single nitrogen vacancy (NV) centers in diamond have been used extensively for high-sensitivity nanoscale sensing, but conventional approaches use confocal microscopy to measure individual centers sequentially, limiting throughput and access to nonlocal physical properties, where simultaneous, high-fidelity measurement of multiple centers is required. Here, we design and implement a multiplexed NV sensing platform that allows us to read out many single NV centers simultaneously using a low-noise camera. Using this platform, we coherently manipulate and read out the spin states of hundreds of individual NV centers in parallel, achieving comparable magnetic field sensitivity to confocal measurements. We also implement a parallelized version of spin-to-charge-conversion readout for low NV center spin state readout noise and use it to demonstrate multiplexed covariance magnetometry, in which we measure ten two-point magnetic field correlators from five NV centers simultaneously. From these measurements, we demonstrate the quantitative reconstruction of spatially varying magnetic correlations arising from a current-carrying wire. The number of correlators we can measure is limited only by the available laser power, opening the door to massively multiplexed covariance magnetometry. In contrast to scanning probes for imaging spatially varying magnetic fields, our approach measures the temporal dynamics of the magnetic field at many precisely defined positions simultaneously, from which the local noise spectrum and nonlocal properties such as correlation functions can be computed. This high-fidelity readout platform will find immediate applications in studying condensed matter phenomena that are characterized by the noise spectrum or correlation functions, including quantum phase transitions, dynamics far from equilibrium, magnetic order, and correlated electron phenomena.
Nitrogen vacancy (NV) centers in diamond are atom-scale defects that can be used to sense magnetic fields with high sensitivity and spatial resolution. Typically, the magnetic field is measured by averaging sequential measurements of single NV centers, or by spatial averaging over ensembles of many NV centers, which provides mean values that contain no nonlocal information about the relationship between two points separated in space or time. Here, we propose and implement a sensing modality whereby two or more NV centers are measured simultaneously, and we extract temporal and spatial correlations in their signals that would otherwise be inaccessible. We demonstrate measurements of correlated applied noise using spin-to-charge readout of two NV centers and implement a spectral reconstruction protocol for disentangling local and nonlocal noise sources.
Nitrogen vacancy (NV) centers in diamond are widely deployed as local magnetic sensors, using coherent, single qubit control to measure both time-averaged fields and noise with nanoscale spatial resolution. Moving beyond single qubits to multi-qubit control enables new sensing modalities such as measuring nonlocal spatiotemporal correlators, or using entangled states to improve measurement sensitivity. Here, we describe protocols to use optically unresolved NV center pairs and nuclear spins as multi-qubit sensors for measuring correlated noise, enabling covariance magnetometry at nanometer length scales. For NV centers that are optically unresolved but have spectrally resolved spin transitions, we implement a phase-cycling protocol that disambiguates magnetic correlations from variance fluctuations by alternating the relative spin orientations of the two NV centers. For NV centers that are both optically and spectrally unresolved, we leverage the presence of a third qubit, a 13C nucleus that is strongly coupled to one of the NV centers, to effect coherent single-NV spin flips and enable a similar phase-cycling protocol. For length scales around 10 nm, we create maximally entangled Bell states through dipole-dipole coupling between two NV centers, and use these entangled states to directly read out the magnetic field correlation, rather than reconstructing it from independent measurements of unentangled NV centers. Importantly, this changes the scaling of sensitivity with readout noise from quadratic to linear. For conventional off-resonant readout of the NV center spin state (for which the readout noise is roughly 30 times the quantum projection limit), this results in a dramatic sensitivity improvement. Finally, we demonstrate methods for the detection of high spatial- and temporal-resolution correlators with pairs of strongly interacting NV centers.
The nitrogen-vacancy (NV) center in diamond is a solid-state spin defect that has been widely adopted for quantum sensing and quantum information processing applications. Typically, experiments are performed either with a single isolated NV center or with an unresolved ensemble of many NV centers, resulting in a trade-off between measurement speed and spatial resolution or control over individual defects. In this work, we introduce an experimental platform that bypasses this trade-off by addressing multiple optically resolved NV centers in parallel. We perform charge- and spin-state manipulations selectively on multiple NV centers from within a larger set, and we manipulate and measure the electronic spin states of over 100 NV centers in parallel. We show that the high signal-to-noise ratio of the measurements enables the detection of shot-to-shot pairwise correlations between the spin states of 108 NV centers, corresponding to the simultaneous measurement of 5778 unique correlation coefficients. We discuss how our platform can be scaled to parallel experiments with thousands of individually resolved NV centers. These results enable parallelized high-throughput sensing experiments that retain the spatial resolution of single defects and will, thereby, help to unlock advances in applications such as single-molecule NMR and characterization of integrated circuits. In addition, our approach to multiplexing provides a natural platform for the application of recently developed correlated sensing techniques.
In modern-day quantum metrology, quantum sensors are widely employed to detect weak magnetic fields or nanoscale signals. Quantum devices, exploiting quantum coherence, are inevitably connected to physical constants and can achieve accuracy, repeatability, and precision approaching fundamental limits. As a result, these sensors have shown utility in a wide range of research domains spanning both science and technology. A rapidly emerging quantum sensing platform employs atomic-scale defects in crystals. In particular, magnetometry using nitrogen-vacancy (NV) color centers in diamond has garnered increasing interest. NV systems possess a combination of remarkable properties, optical addressability, long coherence times, and biocompatibility. Sensors based on NV centers excel in spatial resolution and magnetic sensitivity. These diamond-based sensors promise comparable combination of high spatial resolution and magnetic sensitivity without cryogenic operation. The above properties of NV magnetometers promise increasingly integrated quantum measurement technology, as a result, they have been extensively developed with various protocols and find use in numerous applications spanning materials characterization, nuclear magnetic resonance (NMR), condensed matter physics, paleomagnetism, neuroscience and living systems biology, and industrial vector magnetometry. In this chapter, NV centers are explored for magnetic sensing in a number of contexts. In general, we introduce novel regimes for magnetic-field probes with NV ensembles. Specifically, NV centers are developed for sensitive magnetometers for applications where microwaves (MWs) are prohibitively invasive and operations need to be carried out under zero ambient magnetic field. The primary goal of our discussion is to improve the utility of these NV center-based magnetometers.
Quantum sensing using nitrogen-vacancy (NV) centers in diamond has emerged as a powerful platform for detecting ultra-low magnetic fields under ambient conditions. Owing to their long spin coherence times, optical addressability, and compatibility with aqueous environments, it has found widespread applications in biosensing and bio-imaging. This review presents the fundamental principles and recent advances in NV-based quantum magnetometry for biosensing applications, with a particular focus on measurements in aqueous medium and at cellular and molecular length scales. We discuss the underlying spin physics of NV centers and highlight two primary detection modalities: optically detected magnetic resonance (ODMR) and T1 relaxometry-based sensing and how these approaches aids in the detection of both static magnetic fields and dynamic magnetic noise arising from biological processes. The review explores key application areas, including nanoscale nuclear magnetic resonance (NMR), monitoring of neural activity, detection of abnormal or rogue cells using NV-based platforms etc. In addition, strategies for enhancing sensitivity, such as surface functionalization of nanodiamonds, femtosecond (fs) laser-written photonic structures, and integration with microfluidic and lab-on-chip systems have also been discussed in depth. We also address the critical challenges, including surface-induced decoherence, charge-state instability, and signal-to-noise limitations in biofluids associated with NV-based biosensing applications. Finally, we outline future prospects, highlighting how NV-based magnetic biosensing provides a promising pathway for translating quantum sensing technologies into practical biomedical applications.
The recent decade has witnessed exciting developments in quantum science and technology. Quantum sensing is a rapidly growing branch, which exploits the fragility of quantum systems to detect small external signals. The extreme control at the single-atom level and the remarkably long coherence time of engineered quantum systems enable unprecedented sensitivity and precision, beating the performance of classical techniques. The nitrogen-vacancy (NV) center in diamond is one of the most promising quantum sensors. Its unique advantages have attracted considerable attention, including a long spin coherence time throughout a broad temperature range, nanoscale resolution limited by the sensor-sample distance, convenient optical control of its spin states and remarkably versatile sensing capabilities. Its properties are well studied under a bias magnetic field oriented along its quantization axis. However, its sensing capabilities in the presence of an off-axis magnetic field are much less explored. My research aims to unlock the full potential of NV quantum sensor by developing new sensing modalities under a magnetic field acting perpendicular to the NV axis, and furthermore, integrating them into a scanning probe microscope. In this dissertation, I will report our progress toward building a scanning NV multimodal quantum imaging platform, which will open up exciting opportunities in measuring nanoscale phenomena. The first chapter provides an introduction to the background of quantum sensing with NV centers, followed by a discussion on its basic properties and established sensing techniques. The second and third chapters are dedicated to two experiments performed under a perpendicular magnetic field where traditional NV magnetometry based on the Zeeman effect fails. In the second chapter, I will introduce a new sensing strategy that uses the entanglement between the electron and nuclear spins to restore the magnetic field sensitivity under this unfavored condition. This allows us to sense small changes in the magnetic field angle relative to the NV axis, and to detect anisotropic magnetic noise in the local environment. In the third chapter, I will present our latest development of scanning NV electrometry, where a single NV at the apex of a diamond scanning probe images external alternating (AC) and direct (DC) electric fields with sub-100 nm resolution. In the last chapter, I will discuss our efforts on four experiments that were left unfinished. I will present the results we have achieved, analyze the challenges that we faced and propose potential solutions to overcome them.