Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2607.07044

Absolute frequency measurement of the $^{176}$Lu$^+\,(^{3}\mathrm{D}_1)$ standard against the NRC-FCs2 fountain with $2.6\times10^{-16}$ uncertainty

K. J. Arnold, Bin Jian, Zhao Zhang, Qi Zhao, Qin Qichen, N. Jayjong, M. D. K. Lee, Scott Beattie, M. D. Barrett

physics.atom-phquant-phSubmitted Jul 8, 2026• Announced Jul 9, 2026
v1 · Jul 8, 2026v2 · Sep 28, 2026
arXivHTMLPDF

Abstract

We report an improved absolute frequency measurement of the $^{176}$Lu$^+\,(^{3}\mathrm{D}_1)$ optical frequency standard, evaluated via a remote link to the NRC-FCs2 caesium fountain primary frequency standard. Operating a single ion clock with 94.2% uptime over 10 days, and using an ambiguity-resolved precise point positioning (PPP-AR) link over the Global Positioning System (GPS), we determine an absolute frequency of $353\,638\,794\,073\,800.33(9)\,$Hz at a fractional uncertainty of $2.6 \times 10^{-16}$. This agrees with our previous result, which underpins the CIPM recommended frequency value, and reduces the uncertainty by a factor of 3.6.

Journal reference
Metrologia 63, 055005 (2026)
DOI
10.1088/1681-7575/aea166
Comments
8 pages, 4 figures, 4 tables

Related papers

An Al$^+$ clock with $1.6\times10^{-18}$ systematic uncertainty and its frequency ratios

Fabian Dawel, Johannes Krämer, D. Drapier +15 more

Advances in optical clocks motivate a redefinition of the second, requiring rigorous evaluations of systematic uncertainties and robust consistency among the clocks. Here, we report the full evaluation of the systematic frequency shifts of an $^{27}\mathrm{Al}^+$ single-ion clock, and the measurement of its absolute frequency and frequency ratio with a $^{87}$Sr optical lattice clock at PTB. The evaluated total systematic fractional frequency uncertainty is $1.6\times10^{-18}$, mainly limited by the accuracy of the relevant atomic coefficients and by background gas collisions. The absolute frequency of the clock has been measured to be $ν_{\mathrm{Al}^+}=1 121 015 393 207 859.19(24)\,$Hz, obtained by comparison with two primary caesium fountain clocks at PTB. The frequency ratio between the Al and Sr optical clocks has been determined to be $ν_{\mathrm{Al}^+}/ν_{^{87}\mathrm{Sr}}=2.611 701 431 781 462 668(36)$, limited by the accuracy of the Sr clock. This ratio differs by $8.6σ$ and $1.2σ$ from the 2021 and 2025 frequency ratio published by the BACON collaboration, respectively. These results represent an important contribution toward a future redefinition of the second using optical clocks, and underscore the importance of independent measurements of clock-candidate frequency ratios across different institutions.

arXiv:2606.23151•Jun 22, 2026•3 citations

A STRONTIUM ION OPTICAL FREQUENCY STANDARD WITH Hz-LEVEL UNCERTAINTY

Helen S. Margolis, G. P. Barwood, Guozheng Huang +5 more

The 5 s 2 S 1/2 – 4 d 2 D 5/2 transition at 674 nm in a single laser-cooled trapped 88 Sr + ion serves as the reference for a highly stable and accurate optical frequency standard. A detailed study of the electric quadrupole shift of this reference transition has been carried out, and two techniques for nulling out the quadrupole shift have been experimentally demonstrated. The absolute frequency of the transition has been measured relative to the NPL caesium fountain standard, with an uncertainty of 1.5 Hz or 3.4 parts in 10 15 . Improvements to the experimental arrangement are underway, and are expected to lead to a 88 Sr + optical frequency standard with stability and reproducibility exceeding that of the primary caesium standard.

Laser Spectroscopy•Dec 1, 2005•1 citation

SYSTEMATIC FREQUENCY SHIFTS AND QUANTUM PROJECTION NOISE IN NIST-F1

Steven R. Jefferts, Thomas P. Heavner, J.H. Shirley +1 more

We present results from NIST-F1, the NIST primary frequency standard, a Cesium atomic fountain. In particular we give the results of the latest frequency evaluation which has a combined standard fractional frequency uncertainty of 1.3 × 10 -15 in the laboratory and a total uncertainty of 1.5 × 10 -15 including the time transfer to the Bureau International des Poids et Mesures (BIPM) international atomic time scale (TAI). We also present results that demonstrate the attainment of the quantum projection noise limit in this fountain.

Symposium on Frequency Standards and Metrology•May 1, 2002•3 citations

Improved absolute frequency measurement of the 115In+ 5s 2 1 S 0-5s5p 3 P 0 narrowline transition: Progress towards an optical frequency standard

Y. H. Wang, Tao Liu, Rainer Dumke +7 more

We report on an improved absolute frequency measurement of the 5s 2 1 S 00-5s5p 3 P 0 narrowline clock transition at 236.5 nm, for a single, trapped, and laser-cooled 115In ion. Using a narrowline laser as the local oscillator, a linewidth of 43 Hz for the transition is resolved. The uncertainty of the transition frequency’s centroid is 18 Hz, leading to a fractional uncertainty of 1.4 × 10−14. For absolute frequency measurement, we use an optical frequency comb locked to a cesium clock as the reference. The transition frequency is found to be 1267402452900967(63) Hz, averaged over 13 days of separate measurements. The accuracy is about 5.0 × 10−14. We discuss possibilities for further improvement.

Laser Physics•Jul 1, 2007•9 citations

Lu+ optical frequency references with accuracy verified at the 19th digit

K. J. Arnold, Michael Dao Kang Lee, Qi Zhao +4 more

Optical atomic frequency references1 have far surpassed their microwave frequency predecessors, leading to an anticipated redefinition of the SI (International System of Units) second2. However, as the scientific community seeks consensus on a new standard, and several state-of-the-art optical standards now report evaluated fractional uncertainties below 10−18, verification by same-species comparisons to comparable levels remains an outstanding challenge. Here we report two 176Lu+ single-ion optical frequency references, each with evaluated fractional frequency uncertainty near 1 × 10−19, which are directly compared by correlation spectroscopy and demonstrate agreement, with a measured relative frequency difference of [−0.1 ± (5.7)stat ± (1.0)sys] × 10−19, where ‘stat’ and ‘sys’ indicate the statistical and systematic uncertainty, respectively. Our optical references have been comprehensively assessed with evaluated uncertainties below 10−18, supported by a same-species comparison of independent systems to the 5.7 × 10−19 level. This accuracy, achieved in practical room-temperature systems, will contribute to improving international timekeeping and towards chronometric levelling3,4 at the millimetre scale, as well as tests of fundamental physics5 such as Lorentz invariance6, general relativity7, searches for dark matter8,9 and variation of fundamental constants10,11. Two independent 176Lu+ single-ion optical clocks achieve fractional frequency uncertainties near 10−19 and agree at 5.7 × 10−19, advancing precision timekeeping.

arXiv:2512.07346•Nature•Sep 23, 2026•8 citations

A compact, transportable optical clock with 1×10−17 uncertainty and its absolute frequency measurement

Jian Zhong Cao, Jinbo Yuan, Shaomao Wang +13 more

We report a robust, compact, and transportable optical clock (TOC-729-2) based on a trapped single 40Ca+ ion with a systematic uncertainty of 1.1×10−17, which is limited by the black-body radiation shift uncertainty at room temperature. By comparing it with the previous transportable optical clock (TOC-729-1) similar but completely independent, the instability was measured to be better than 1.2×10−14/τ. Benefiting from the modular and integrated design, this TOC was constructed in a volume of ∼0.33 m3 excluding the controlling electronics in 19-in. racks. After being moved ∼1200 km away by express delivery, the single-ion signal was restored within 24 h. With the TOC uptime of 92% in 35-day period, the absolute frequency of the 729 nm transition of 40Ca+ was measured using a satellite link to International Atomic Time (TAI) to provide traceability to the SI second, and the result is 411 042 129 776 400.15(22) Hz, corresponding to a relative uncertainty of 5.3×10−16.

Applied Physics Letters•Jan 31, 2022•23 citations
Absolute frequency measurement of the 176^{176}176Lu+ (3D1)^+\,(^{3}\mathrm{D}_1)+(3D1​) standard against the NRC-FCs2 fountain with 2.6×10−162.6\times10^{-16}2.6×10−16 uncertainty
We report an improved absolute frequency measurement of the 176^{176}176Lu+ (3D1)^+\,(^{3}\mathrm{D}_1)+(3D1​) optical frequency standard, evaluated via a remote link to the NRC-FCs2 caesium fountain primary frequency standard. Operating a single ion clock with 94.2% uptime over 10 days, and using an ambiguity-resolved precise point positioning (PPP-AR) link over the Global Positioning System (GPS), we determine an absolute frequency of 353 638 794 073 800.33(9) 353\,638\,794\,073\,800.33(9)\,353638794073800.33(9)Hz at a fractional uncertainty of 2.6×10−162.6 \times 10^{-16}2.6×10−16. This agrees with our previous result, which underpins the CIPM recommended frequency value, and reduces the uncertainty by a factor of 3.6.
An Al+^++ clock with 1.6×10−181.6\times10^{-18}1.6×10−18 systematic uncertainty and its frequency ratios
Advances in optical clocks motivate a redefinition of the second, requiring rigorous evaluations of systematic uncertainties and robust consistency among the clocks. Here, we report the full evaluation of the systematic frequency shifts of an 27Al+^{27}\mathrm{Al}^+27Al+ single-ion clock, and the measurement of its absolute frequency and frequency ratio with a 87^{87}87Sr optical lattice clock at PTB. The evaluated total systematic fractional frequency uncertainty is 1.6×10−181.6\times10^{-18}1.6×10−18, mainly limited by the accuracy of the relevant atomic coefficients and by background gas collisions. The absolute frequency of the clock has been measured to be νAl+=1121015393207859.19(24) ν_{\mathrm{Al}^+}=1 121 015 393 207 859.19(24)\,νAl+​=1121015393207859.19(24)Hz, obtained by comparison with two primary caesium fountain clocks at PTB. The frequency ratio between the Al and Sr optical clocks has been determined to be νAl+/ν87Sr=2.611701431781462668(36)ν_{\mathrm{Al}^+}/ν_{^{87}\mathrm{Sr}}=2.611 701 431 781 462 668(36)νAl+​/ν87Sr​=2.611701431781462668(36), limited by the accuracy of the Sr clock. This ratio differs by 8.6σ8.6σ8.6σ and 1.2σ1.2σ1.2σ from the 2021 and 2025 frequency ratio published by the BACON collaboration, respectively. These results represent an important contribution toward a future redefinition of the second using optical clocks, and underscore the importance of independent measurements of clock-candidate frequency ratios across different institutions.
The 5 s 2 S 1/2 – 4 d 2 D 5/2 transition at 674 nm in a single laser-cooled trapped 88 Sr + ion serves as the reference for a highly stable and accurate optical frequency standard. A detailed study of the electric quadrupole shift of this reference transition has been carried out, and two techniques for nulling out the quadrupole shift have been experimentally demonstrated. The absolute frequency of the transition has been measured relative to the NPL caesium fountain standard, with an uncertainty of 1.5 Hz or 3.4 parts in 10 15 . Improvements to the experimental arrangement are underway, and are expected to lead to a 88 Sr + optical frequency standard with stability and reproducibility exceeding that of the primary caesium standard.
We present results from NIST-F1, the NIST primary frequency standard, a Cesium atomic fountain. In particular we give the results of the latest frequency evaluation which has a combined standard fractional frequency uncertainty of 1.3 × 10 -15 in the laboratory and a total uncertainty of 1.5 × 10 -15 including the time transfer to the Bureau International des Poids et Mesures (BIPM) international atomic time scale (TAI). We also present results that demonstrate the attainment of the quantum projection noise limit in this fountain.
We report on an improved absolute frequency measurement of the 5s 2 1 S 00-5s5p 3 P 0 narrowline clock transition at 236.5 nm, for a single, trapped, and laser-cooled 115In ion. Using a narrowline laser as the local oscillator, a linewidth of 43 Hz for the transition is resolved. The uncertainty of the transition frequency’s centroid is 18 Hz, leading to a fractional uncertainty of 1.4 × 10−14. For absolute frequency measurement, we use an optical frequency comb locked to a cesium clock as the reference. The transition frequency is found to be 1267402452900967(63) Hz, averaged over 13 days of separate measurements. The accuracy is about 5.0 × 10−14. We discuss possibilities for further improvement.
Optical atomic frequency references1 have far surpassed their microwave frequency predecessors, leading to an anticipated redefinition of the SI (International System of Units) second2. However, as the scientific community seeks consensus on a new standard, and several state-of-the-art optical standards now report evaluated fractional uncertainties below 10−18, verification by same-species comparisons to comparable levels remains an outstanding challenge. Here we report two 176Lu+ single-ion optical frequency references, each with evaluated fractional frequency uncertainty near 1 × 10−19, which are directly compared by correlation spectroscopy and demonstrate agreement, with a measured relative frequency difference of [−0.1 ± (5.7)stat ± (1.0)sys] × 10−19, where ‘stat’ and ‘sys’ indicate the statistical and systematic uncertainty, respectively. Our optical references have been comprehensively assessed with evaluated uncertainties below 10−18, supported by a same-species comparison of independent systems to the 5.7 × 10−19 level. This accuracy, achieved in practical room-temperature systems, will contribute to improving international timekeeping and towards chronometric levelling3,4 at the millimetre scale, as well as tests of fundamental physics5 such as Lorentz invariance6, general relativity7, searches for dark matter8,9 and variation of fundamental constants10,11. Two independent 176Lu+ single-ion optical clocks achieve fractional frequency uncertainties near 10−19 and agree at 5.7 × 10−19, advancing precision timekeeping.
We report a robust, compact, and transportable optical clock (TOC-729-2) based on a trapped single 40Ca+ ion with a systematic uncertainty of 1.1×10−17, which is limited by the black-body radiation shift uncertainty at room temperature. By comparing it with the previous transportable optical clock (TOC-729-1) similar but completely independent, the instability was measured to be better than 1.2×10−14/τ. Benefiting from the modular and integrated design, this TOC was constructed in a volume of ∼0.33 m3 excluding the controlling electronics in 19-in. racks. After being moved ∼1200 km away by express delivery, the single-ion signal was restored within 24 h. With the TOC uptime of 92% in 35-day period, the absolute frequency of the 729 nm transition of 40Ca+ was measured using a satellite link to International Atomic Time (TAI) to provide traceability to the SI second, and the result is 411 042 129 776 400.15(22) Hz, corresponding to a relative uncertainty of 5.3×10−16.