The Bell-Bloom-type optically-pumped FID Rubidium atomic magnetometer with a multi-passing probe beam and two counter-propagating pump beams

Yongbiao Yang, Zhengyu Su, Yang Li, Yanhua Wang, Jun He, Xiaojun Jia, Junmin Wang

Published Apr 3, 2026• 0 citations
arXivHTMLPDF

Abstract

The Bell-Bloom-type optically pumped atomic magnetometers are well suited for weak geomagnetic field detection. However, conventional single-beam pumping introduces an atomic spin polarization gradient, which limits the measurement accuracy and sensitivity. To address this issue, this paper proposes and experimentally demonstrates a Bell-Bloom-type rubidium FID magnetometer scheme integrating orthogonally polarized counter-propagating pumping and multi-pass probe detection. This design homogenizes the atomic spin polarization distribution and suppresses light shifts and power broadening effects induced by the pump beam. Meanwhile, the five-pass probe configuration significantly enhances the signal amplitude. Experimental results reveal that, compared with the traditional single-beam pumping and single-pass detection scheme, the proposed magnetometer achieves a remarkable improvement in magnetic field measurement accuracy, and the magnetic field sensitivity is improved from 18.9 pT/\sqrt{Hz} to 3.1 pT/\sqrt{Hz}. This work provides an effective technical approach and reference for optimizing the performance of atomic magnetometers and extending their applications in integrated arrays.

DOI
10.48550/arxiv.2604.02865

Related papers

The Bell‐Bloom‐Type Optically‐Pumped FID Rubidium Atomic Magnetometer With a Multi‐Passing Probe Beam and Two Counter‐Propagating Pump Beams

Yongbiao Yang, Zhengyu Su, Yang Li +4 more

ABSTRACT The Bell‐Bloom‐type optically‐pumped atomic magnetometers are well‐suited for weak geomagnetic field detection. However, conventional single‐beam pumping introduces an atomic spin polarization gradient, which limits the measurement accuracy and sensitivity. To address this issue, this paper proposes and experimentally demonstrates a Bell‐Bloom‐type rubidium FID magnetometer scheme integrating orthogonally polarized counter‐propagating pumping and multi‐pass probe detection. This design homogenizes the atomic spin polarization distribution and suppresses light shifts and power broadening. This uniform polarization, in turn, allows the five‐pass probe configuration to achieve a significantly larger signal amplitude. Experimental results reveal that, compared with the traditional single‐beam pumping and single‐pass detection scheme, the proposed magnetometer achieves a remarkable improvement in magnetic field measurement accuracy, and the magnetic field sensitivity is improved from 18.9 to 3.1 pT/. Notably, the two techniques work synergistically, yielding a 6.1‐fold sensitivity enhancement that far exceeds their individual gains. This work provides an effective technical approach and reference for optimizing the performance of atomic magnetometers and their applications in precision measurement fields.

Annalen der Physik•Jul 1, 2026•1 citation

A Multi-Pass Optically Pumped Rubidium Atomic Magnetometer with Free Induction Decay

Lulu Zhang, Yongbiao Yang, Ni Zhao +2 more

A free-induction-decay (FID) type optically-pumped rubidium atomic magnetometer driven by a radio-frequency (RF) magnetic field is presented in this paper. Influences of parameters, such as the temperature of rubidium vapor cell, the power of pump beam, and the strength of RF magnetic field and static magnetic field on the amplitude and the full width at half maximum (FWHM) of the FID signal, have been investigated in the time domain and frequency domain. At the same time, the sensitivities of the magnetometer for the single-pass and the triple-pass probe beam cases have been compared by changing the optical path of the interaction between probe beam and atomic ensemble. Compared with the sensitivity of ∼21.2 pT/Hz1/2 in the case of the single-pass probe beam, the amplitude of FID signal in the case of the triple-pass probe beam has been significantly enhanced, and the sensitivity has been improved to ∼13.4 pT/Hz1/2. The research in this paper provids a reference for the subsequent study of influence of different buffer gas pressure on the FWHM and also a foundation for further improving the sensitivity of FID rubidium atomic magnetometer by employing a polarization-squeezed light as probe beam, to achieve a sensitivity beyond the photo-shot-noise level.

arXiv:2301.08437•Sensors•Oct 7, 2022•18 citations

Faraday-rotation Bell–Bloom atomic magnetometer using an alternating pump–probe beam

Songsong Li, Yi Zhang, Yuan Tian +2 more

We propose a scheme for a Bell–Bloom atomic magnetometer based on a single beam. In our approach, the light is periodically modulated synchronously with Larmor precession. As a result, the light that interacts with atoms is alternately polychromatic and monochromatic. When the light is polychromatic, the ±1st sidebands of the light are optically resonant with the atoms, and the atoms are polarized by pumping. When the light is monochromatic, a differential detection technique extracts the Faraday-rotation signal of the light, and the polarization of the light is probed. We demonstrate an experimental implementation of the Bell–Bloom magnetometer that achieves a sensitivity for magnetic-field detection of 0.25 pT/Hz1/2 at 1 Hz. Our scheme is suitable for developing compact, miniaturized magnetometers.

Journal of Applied Physics•Aug 25, 2021•16 citations

Dead-zone-free free-induction-decay alkali-metal atomic magnetometer

X.-K. Wang, J. He, HH Deng +2 more

The detection dead zone is an important systematic limitation in scalar atomic magnetometers, constraining their practical utility. In this work, we demonstrate a sensitive dead zone free scalar magnetometer by integrating previously established techniques into a FID magnetometer based on Bell Bloom optical pumping. The dead zone is eliminated by inserting a reflecting mirror within a multipass cavity assisted atomic cell, which folds the optical beam into orthogonal paths. Our analysis reveals that interregion cross talk is essential for interpreting the resulted experimental signals. The sensor exhibits oscillation signal amplitude variations within a factor of three across all orientations in three dimensional space, and a field sensitivity better than 80 fT/Hz^(1/2) over the full space. We further characterize the heading error in the geomagnetic field range, where experimental results agree with theoretical predictions within 0.7 nT. Additionally, the sensor can operate in a closed loop mode by feeding back the real time frequency extracted from the FID signal to modulate the pump beam, we characterize the magnetic field slew rate of the sensor. This work paves the way towards a sensitive vector FID magnetometer.

arXiv:2609.04847•Physical Review A•Aug 25, 2026•0 citations

Total-field atomic magnetometry using an elliptically-polarized frequency-modulated light beam for geomagnetic-field applications

Denis V. Brazhnikov, A. O. Makarov, K. S. Kozlova +10 more

We investigate an all-optical scheme for high-sensitivity measurements of the Earth's scale magnetic field ($B$). The scheme is based on the Bell-Bloom technique with frequency-modulated light. A single elliptically polarized light beam is used both for pumping the alkali-metal atoms and probing Larmor precession of their spins under the external magnetic field. In contrast to many other high-sensitivity magnetometry schemes based on nonlinear polarization rotation of the light, the proposed approach enables the observation of magnetic resonance via changes in the light-beam ellipticity parameter. The approach has been validated in experiments with a vertical-cavity surface-emitting laser, irradiating a $0.125$ cm$^3$ cesium vapor cell filled with a buffer gas. In the current experimental conditions, the achieved sensitivity is estimated at $220$ fT/$\surd$Hz under $B$$\,\approx\,$$50$ $μ$T, while the shot-noise floor corresponds to $\approx\,$$20$ fT/$\surd$Hz. The bandwidth is estimated at $\approx\,$$1$ kHz. The proposed simple and robust single-beam scheme is well suited for miniaturization and is therefore particularly promising for the development of compact, highly sensitive, low-power-consumption atomic magnetometers for a wide range of applications in the geomagnetic field.

arXiv:2610.08031•Oct 6, 2026•0 citations

Dead-zone-free single-beam atomic magnetometer based on free-induction-decay of Rb atoms

Shrey Mehta, G. K. Samanta, Raghwinder Singh Grewal

Free-induction-decay (FID) magnetometers have evolved as simple magnetic sensors for sensitive detection of unknown magnetic fields. However, these magnetometers suffer from a fundamental problem known as a “dead zone,” making them insensitive to certain magnetic field directions. Here, we demonstrate a simple experimental scheme for the dead-zone-free operation of a FID atomic magnetometer. Using a single laser beam containing equal strength of linear- and circular-polarization components and amplitude modulation at a low-duty cycle, we have synchronously pumped the rubidium (87Rb) atoms with both first- and second-order frequency harmonics. Such a pumping scheme has enabled us to observe the free Larmor precession of atomic spins at a frequency of ΩL (orientation) and/or 2ΩL (alignment) in a single FID signal, depending on the direction of the external magnetic field. We observed that the amplitude of the FID signal does not go to zero for any magnetic field direction, proving the absence of dead zones in the magnetometer. The magnetometer has a sensitivity in the range of 3.2–8.4 pT/Hz in all directions. Our experimental scheme can be crucial in developing miniaturized atomic magnetometers for various practical applications, including geomagnetic applications.

arXiv:2410.15663•Applied Physics Letters•Jan 27, 2025•8 citations
The Bell-Bloom-type optically pumped atomic magnetometers are well suited for weak geomagnetic field detection. However, conventional single-beam pumping introduces an atomic spin polarization gradient, which limits the measurement accuracy and sensitivity. To address this issue, this paper proposes and experimentally demonstrates a Bell-Bloom-type rubidium FID magnetometer scheme integrating orthogonally polarized counter-propagating pumping and multi-pass probe detection. This design homogenizes the atomic spin polarization distribution and suppresses light shifts and power broadening effects induced by the pump beam. Meanwhile, the five-pass probe configuration significantly enhances the signal amplitude. Experimental results reveal that, compared with the traditional single-beam pumping and single-pass detection scheme, the proposed magnetometer achieves a remarkable improvement in magnetic field measurement accuracy, and the magnetic field sensitivity is improved from 18.9 pT/\sqrt{Hz} to 3.1 pT/\sqrt{Hz}. This work provides an effective technical approach and reference for optimizing the performance of atomic magnetometers and extending their applications in integrated arrays.
ABSTRACT The Bell‐Bloom‐type optically‐pumped atomic magnetometers are well‐suited for weak geomagnetic field detection. However, conventional single‐beam pumping introduces an atomic spin polarization gradient, which limits the measurement accuracy and sensitivity. To address this issue, this paper proposes and experimentally demonstrates a Bell‐Bloom‐type rubidium FID magnetometer scheme integrating orthogonally polarized counter‐propagating pumping and multi‐pass probe detection. This design homogenizes the atomic spin polarization distribution and suppresses light shifts and power broadening. This uniform polarization, in turn, allows the five‐pass probe configuration to achieve a significantly larger signal amplitude. Experimental results reveal that, compared with the traditional single‐beam pumping and single‐pass detection scheme, the proposed magnetometer achieves a remarkable improvement in magnetic field measurement accuracy, and the magnetic field sensitivity is improved from 18.9 to 3.1 pT/. Notably, the two techniques work synergistically, yielding a 6.1‐fold sensitivity enhancement that far exceeds their individual gains. This work provides an effective technical approach and reference for optimizing the performance of atomic magnetometers and their applications in precision measurement fields.
A free-induction-decay (FID) type optically-pumped rubidium atomic magnetometer driven by a radio-frequency (RF) magnetic field is presented in this paper. Influences of parameters, such as the temperature of rubidium vapor cell, the power of pump beam, and the strength of RF magnetic field and static magnetic field on the amplitude and the full width at half maximum (FWHM) of the FID signal, have been investigated in the time domain and frequency domain. At the same time, the sensitivities of the magnetometer for the single-pass and the triple-pass probe beam cases have been compared by changing the optical path of the interaction between probe beam and atomic ensemble. Compared with the sensitivity of ∼21.2 pT/Hz1/2 in the case of the single-pass probe beam, the amplitude of FID signal in the case of the triple-pass probe beam has been significantly enhanced, and the sensitivity has been improved to ∼13.4 pT/Hz1/2. The research in this paper provids a reference for the subsequent study of influence of different buffer gas pressure on the FWHM and also a foundation for further improving the sensitivity of FID rubidium atomic magnetometer by employing a polarization-squeezed light as probe beam, to achieve a sensitivity beyond the photo-shot-noise level.
We propose a scheme for a Bell–Bloom atomic magnetometer based on a single beam. In our approach, the light is periodically modulated synchronously with Larmor precession. As a result, the light that interacts with atoms is alternately polychromatic and monochromatic. When the light is polychromatic, the ±1st sidebands of the light are optically resonant with the atoms, and the atoms are polarized by pumping. When the light is monochromatic, a differential detection technique extracts the Faraday-rotation signal of the light, and the polarization of the light is probed. We demonstrate an experimental implementation of the Bell–Bloom magnetometer that achieves a sensitivity for magnetic-field detection of 0.25 pT/Hz1/2 at 1 Hz. Our scheme is suitable for developing compact, miniaturized magnetometers.
The detection dead zone is an important systematic limitation in scalar atomic magnetometers, constraining their practical utility. In this work, we demonstrate a sensitive dead zone free scalar magnetometer by integrating previously established techniques into a FID magnetometer based on Bell Bloom optical pumping. The dead zone is eliminated by inserting a reflecting mirror within a multipass cavity assisted atomic cell, which folds the optical beam into orthogonal paths. Our analysis reveals that interregion cross talk is essential for interpreting the resulted experimental signals. The sensor exhibits oscillation signal amplitude variations within a factor of three across all orientations in three dimensional space, and a field sensitivity better than 80 fT/Hz^(1/2) over the full space. We further characterize the heading error in the geomagnetic field range, where experimental results agree with theoretical predictions within 0.7 nT. Additionally, the sensor can operate in a closed loop mode by feeding back the real time frequency extracted from the FID signal to modulate the pump beam, we characterize the magnetic field slew rate of the sensor. This work paves the way towards a sensitive vector FID magnetometer.
We investigate an all-optical scheme for high-sensitivity measurements of the Earth's scale magnetic field (BBB). The scheme is based on the Bell-Bloom technique with frequency-modulated light. A single elliptically polarized light beam is used both for pumping the alkali-metal atoms and probing Larmor precession of their spins under the external magnetic field. In contrast to many other high-sensitivity magnetometry schemes based on nonlinear polarization rotation of the light, the proposed approach enables the observation of magnetic resonance via changes in the light-beam ellipticity parameter. The approach has been validated in experiments with a vertical-cavity surface-emitting laser, irradiating a 0.1250.1250.125 cm3^33 cesium vapor cell filled with a buffer gas. In the current experimental conditions, the achieved sensitivity is estimated at 220220220 fT/√\surd√Hz under BBB ≈ \,\approx\,≈505050 μμμT, while the shot-noise floor corresponds to ≈ \approx\,≈202020 fT/√\surd√Hz. The bandwidth is estimated at ≈ \approx\,≈111 kHz. The proposed simple and robust single-beam scheme is well suited for miniaturization and is therefore particularly promising for the development of compact, highly sensitive, low-power-consumption atomic magnetometers for a wide range of applications in the geomagnetic field.
Free-induction-decay (FID) magnetometers have evolved as simple magnetic sensors for sensitive detection of unknown magnetic fields. However, these magnetometers suffer from a fundamental problem known as a “dead zone,” making them insensitive to certain magnetic field directions. Here, we demonstrate a simple experimental scheme for the dead-zone-free operation of a FID atomic magnetometer. Using a single laser beam containing equal strength of linear- and circular-polarization components and amplitude modulation at a low-duty cycle, we have synchronously pumped the rubidium (87Rb) atoms with both first- and second-order frequency harmonics. Such a pumping scheme has enabled us to observe the free Larmor precession of atomic spins at a frequency of ΩL (orientation) and/or 2ΩL (alignment) in a single FID signal, depending on the direction of the external magnetic field. We observed that the amplitude of the FID signal does not go to zero for any magnetic field direction, proving the absence of dead zones in the magnetometer. The magnetometer has a sensitivity in the range of 3.2–8.4 pT/Hz in all directions. Our experimental scheme can be crucial in developing miniaturized atomic magnetometers for various practical applications, including geomagnetic applications.